1. Samfurin Ya Ƙareview

The Legrand Green'up Premium three-phase charging station is designed for safe and efficient recharging of electric vehicles and plug-in hybrids. This station supports both Mode 2 and Mode 3 charging, accommodating vehicles equipped with single-phase and three-phase chargers. It complies with international standards IEC 61851-1 and IEC 61851-22, ensuring reliable and secure operation.

Legrand Green'up Premium Three-Phase Charging Station

Hoto 1.1: Gaba view of the Legrand Green'up Premium Three-Phase Charging Station.

2. Saita da Shigarwa

This section provides general guidelines for setting up your Legrand Green'up Premium charging station. For detailed installation instructions, please refer to the dedicated installation manual included in the product packaging. Installation must be performed by a qualified electrician in accordance with local electrical codes and regulations.

2.1. Buɗe Akwatin

Carefully unpack all components and verify that all items are present.

  • Legrand Green'up Premium Charging Station
  • Installation Instructions (French, if applicable)

2.2. Mounting the Station

Choose a suitable location for mounting the charging station, ensuring it is protected from direct impact and adverse weather conditions if installed outdoors. The station should be mounted securely to a solid surface at an appropriate height for user access.

Na baya view of Legrand Green'up Premium Charging Station showing mounting points

Hoto 2.1: Na baya view of the charging station, indicating potential mounting points or cable entry.

2.3. Haɗin Lantarki

Connect the charging station to the electrical supply. This is a three-phase unit requiring a 32A supply. Ensure proper grounding and overcurrent protection are in place as per local regulations. Refer to the wiring diagrams in the installation manual for specific connection details.

3. Umarnin Aiki

Follow these steps to safely charge your electric vehicle using the Legrand Green'up Premium charging station.

  1. Shirya Motar ku: Ensure your electric vehicle is parked safely and switched off.
  2. Open Charging Port: Open the charging port cover on your vehicle.
  3. Haɗa Cable Cajin: Take the appropriate charging cable (not included with the station) and connect one end to the charging station's port.
  4. Close-up of Legrand Green'up Premium Charging Station port cover

    Image 3.1: Close-up of the charging station's port cover, ready for cable connection.

  5. Haɗa zuwa Mota: Connect the other end of the charging cable to your vehicle's charging port.
  6. Fara Cajin: The charging station will typically detect the connection and initiate the charging process automatically. Indicators on the station (if present) or your vehicle will show the charging status.
  7. Saka idanu Cajin: Monitor the charging progress via your vehicle's dashboard or the station's indicators.
  8. Ƙarshen Caji: Once charging is complete, or if you need to stop charging, follow your vehicle's instructions to safely disconnect the cable from the vehicle first, then from the charging station.

Muhimmi: Always ensure the charging cable is fully inserted and secured before initiating charging. Never force connections. If an error occurs, refer to the Troubleshooting section.

4. Kulawa

Regular maintenance ensures the longevity and safe operation of your charging station. Always disconnect power to the unit before performing any maintenance.

  • Tsaftacewa: Periodically clean the exterior of the charging station with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the charging port is free from dust, dirt, and moisture.
  • Duban Kebul: Regularly inspect the charging cable (if permanently attached or your own) for any signs of damage, wear, or fraying. Replace damaged cables immediately.
  • Binciken tashar jiragen ruwa: Check the charging port for any foreign objects or damage. Ensure the protective cover (if applicable) is functioning correctly.
  • Binciken Ƙwararru: It is recommended to have the charging station inspected by a qualified electrician at least once a year to ensure all electrical connections are secure and the unit is operating safely.

5. Shirya matsala

This section addresses common issues you might encounter with your charging station. For more complex problems, contact a qualified electrician or Legrand customer support.

MatsalaDalili mai yiwuwaMagani
No Power to StationCircuit breaker tripped; loose electrical connection.Check the circuit breaker in your electrical panel and reset if tripped. Ensure all connections are secure (requires a qualified electrician).
Vehicle Not ChargingCable not fully connected; vehicle charging fault; station fault.Ensure the charging cable is securely connected to both the station and the vehicle. Check your vehicle's dashboard for error messages. Disconnect and reconnect the cable.
A hankali CajiVehicle settings; external factors (e.g., grid load); cable issue.Check your vehicle's charging settings. Ensure the charging cable is rated for the station's capacity. Consult your vehicle's manual.
Error Indicator Light OnInternal fault; external electrical issue.Disconnect the charging cable, then power cycle the station (turn off and on the circuit breaker). If the error persists, contact Legrand support.

6. Bayanan fasaha

SiffarDaki-daki
AlamarLegrand
Lambar Samfura59002 (Part Number: 059002)
Sunan Nau'in SamfuraCar Charging Socket
Iyawa22 kW
Ƙididdiga na Yanzu32 A
VoltageThree-phase (specific voltage depends on regional supply, typically 400V AC)
Yanayin CajiMode 3 (compatible with Mode 2 vehicles)
Ma'auni masu dacewaIEC 61851-1, IEC 61851-22
Nauyin Abu3.79 kilogiram
Ƙarar20.40 dmn
An kiyasta Lokacin Cajin9 hours (dependent on vehicle battery capacity and state of charge)
Kayan abuFilastik

7. Garanti da Tallafawa

7.1. Garanti na masana'anta

This Legrand Green'up Premium charging station is covered by a Garanti na masana'anta na shekara 2. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims. The warranty does not cover damage caused by improper installation, misuse, accidents, or unauthorized modifications.

7.2. Tallafin Abokin Ciniki

For technical assistance, warranty claims, or further information, please contact Legrand customer support. Visit the official Legrand webshafin don bayanan tuntuɓar takamaiman yankin ku.

Legrand Official Website: www.legrand.com

Lokacin da kake tuntuɓar tallafi, da fatan za a sami lambar samfurin samfurinka (59002) da kuma shaidar siyayya a shirye.

© 2023 Legrand. An kiyaye duk haƙƙoƙi. Bayanan da ke cikin wannan littafin jagora na iya canzawa ba tare da sanarwa ba.

Takardu masu alaƙa - 59002

Preview Legrand Green'up Charging Stations Service Guide
Comprehensive service guide for Legrand Green'up electric vehicle charging stations, covering safety instructions, maintenance schedules, troubleshooting, product specifications, and maintenance logs.
Preview Legrand HPi 33 EVO 20kVA Three-Phase UPS System - Technical Specifications
Detailed technical specifications for the Legrand HPi 33 EVO 20kVA three-phase Uninterruptible Power Supply (UPS) system, including characteristics, input/output data, battery, communication, environmental, and mechanical details.
Preview Legrand PDU Switched Base 0U, Mataki na 3 16A, 21 C13 + 3 C19 tare da Kullewa - Bayanin Fasaha
Technical specification for the Legrand PDU Switched Base 0U, a 3-phase 16A Power Distribution Unit featuring 21 C13 and 3 C19 outlets with locking connectors, designed for 19-inch rack environments. Details include management capabilities (wireless via Pod Master, wired RS485 cascade), electrical specifications, mechanical characteristics, mounting options, and compliance standards.
Preview Legrand PDU Mai Ma'aunin Tushe Inci 19, Mataki na 1 na 16A, Makullan Kulle C13 guda 8, IEC-320 C20 - Takardar Bayanan Fasaha
Technical specifications and features for the Legrand PDU Metered Base 19 Inch, 1 Phase 16A, 8 C13 Locking Outlets, IEC-320 C20. Details on general specifications, input/output, controller, management options, mechanical and environmental characteristics, dimensions, mounting, and standards.
Preview Legrand 310332 19-inch Rack PDU with Integrated UPS: Safety Information and Operation Guide
Comprehensive safety information, installation, operation, and disposal guidelines for the Legrand 310332 19-inch rack PDU with an integrated 800 VA / 480 W UPS, featuring 8 Schuko outlets.
Preview Legrand PDU Switched Node 0U, Mataki na 1 32A, 20 C13 + 2C 19 Makulli Shafuka, IEC 60309 - Takardar Bayanan Fasaha
Technical data sheet for the Legrand PDU Switched Node 0U, a 1-phase 32A power distribution unit featuring 20 C13 and 2 C19 locking outlets, designed for IT equipment in 19-inch enclosures. Details key features, specifications, input/output, controller, cascading modes, mechanical and environmental characteristics, mounting solutions, packaging, and standards.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.