Inventum AC901
Jagorar Mai Amfani da Na'urar Kwandishan Mai Ɗauki ta Inventum AC901
Model: AC901 | Brand: Inventum
1. Muhimman Bayanan Tsaro
Please read this manual carefully before operating your Inventum AC901 Portable Air Conditioner. Keep it for future reference. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Tsaron Wutar Lantarki: Always plug the unit into a grounded electrical outlet. Do not use extension cords or adapter plugs. Ensure the voltage ya dace da buƙatun na'urar (220-240V, 50Hz).
- Wuri: Place the unit on a flat, stable surface. Maintain at least 30 cm (12 inches) clearance from walls and other objects to ensure proper airflow.
- Samun iska: Ensure the exhaust hose is properly installed and vented outdoors to expel hot air. Do not block the air inlets or outlets.
- Yara da Dabbobi: Keep children and pets away from the unit during operation. This appliance is not intended for use by persons with reduced physical, sensory or mental capabilities unless supervised.
- Tsaftacewa da Kulawa: Always unplug the unit before cleaning or performing any maintenance. Do not use harsh chemicals or abrasive cleaners.
- Magudanar Ruwa: Regularly check and drain the water tank to prevent overflow, especially in dehumidifying mode.
2. Samfurin Ya Ƙareview
Familiarize yourself with the components of your Inventum AC901 Portable Air Conditioner.

Hoto na 2.1: Gede view of the Inventum AC901 Portable Air Conditioner, showing its compact design and integrated wheels for easy mobility.

Hoto na 2.2: Gaba view of the AC901 unit, highlighting the air outlet grille and the 'INVENTUM' branding.

Hoto na 2.3: Close-up of the top control panel with touch buttons for Power, Mode, Temperature adjustment, Fan Speed, and Timer, along with a digital display.

Hoto na 2.4: The remote control for the AC901, featuring buttons for Speed, Temp+, Mode, Temp-, Timer, and Power, allowing convenient operation from a distance.
Babban abubuwan:
- Kwamitin Gudanarwa: Located on top of the unit, with touch buttons and a digital display.
- Fitar Jirgin Sama: Front grille where conditioned air is expelled.
- Rukunin Jirgin Sama: Rear or side grilles where air is drawn into the unit.
- Haɗin Tushen Ƙarfafawa: Port at the rear for attaching the exhaust hose.
- Water Drain Port: For manual or continuous drainage of condensed water.
- Kaster Wheels: Don sauƙin motsi na naúrar.
- Ikon nesa: Don aiki mai dacewa daga nesa.
3. Saita
Bi waɗannan matakan don saita na'urar sanyaya iska mai ɗaukuwa don ingantaccen aiki.
3.1 Buɗewa
- A hankali cire naúrar da duk na'urorin haɗi daga marufi.
- Check for any shipping damage. If damaged, do not operate and contact customer support.
- Riƙe marufi na asali don ajiya ko sufuri na gaba.
3.2 Wuri
Choose a suitable location for your air conditioner.
- Sanya naúrar a kan m, matakin saman.
- Ensure there is at least 30 cm (12 inches) of clear space around the unit for proper air circulation.
- Position the unit near a window or door for easy exhaust hose installation.

Hoto na 3.1: Dimensions of the Inventum AC901 unit: 33cm (width) x 28cm (depth) x 68cm (height), useful for planning placement.
3.3 Shigar da Tiyo Mai Shaye-shaye
The exhaust hose is crucial for expelling hot air from the room.
- Attach the exhaust hose connector to the rear outlet of the unit.
- Faɗa bututun shaye-shaye sannan a haɗa adaftar kayan aikin taga zuwa ɗayan ƙarshen.
- Install the window kit in a suitable window opening, ensuring a tight seal to prevent hot air from re-entering the room.
- Ensure the exhaust hose is as short and straight as possible to maximize efficiency. Avoid kinks or sharp bends.
3.4 Haɗin Wuta
- Plug the power cord into a grounded 220-240V, 50Hz electrical outlet.
- Do not share the outlet with other high-power appliances.
4. Umarnin Aiki
Learn how to operate your Inventum AC901 using the control panel or remote control.
4.1 Ayyukan Gudanarwa
- Maballin Wuta (⏻): Danna don kunna naúrar ko KASHE.
- Maɓallin Yanayin (◩): Press to cycle through operating modes: Cool, Heat, Dehumidify, Fan.
- Ƙara Zafin Jiki (+) / Ƙasa (-) Maɓallan: Daidaita yanayin zafin da ake so.
- Maɓallin Saurin Fanka (⟳): Select fan speed (Low, Medium, High).
- Maɓallin Mai ƙidayar lokaci (◷): Set the auto-on or auto-off timer.
- Nunawa: Yana nuna yanayin zafi na yanzu, saitunan ƙidayar lokaci, da lambobin kuskure.
4.2 Ayyuka masu nisa
The remote control duplicates most functions of the control panel for convenience.
- WUTA: Yana kunna naúrar ON/KASHE.
- kwatance: Cycles through operating modes.
- TEMP+ / TEMP-: Yana daidaita zafin jiki.
- SAURI: Yana daidaita saurin fan.
- TIMER: Sets the timer function.
4.3 Hanyoyin Aiki
- Yanayin sanyaya: Lowers room temperature. Set desired temperature using TEMP+/- buttons.
- Yanayin dumama: Raises room temperature. Set desired temperature using TEMP+/- buttons.
- Yanayin Rage Danshi: Removes excess moisture from the air. Fan speed is typically fixed in this mode.
- Yanayin Fan: Yana kewaya iska ba tare da sanyaya ko dumama ba. Zaɓi saurin fan da ake so.
4.4 Aiki mai ƙidayar lokaci
The timer allows you to set the unit to automatically turn on or off after a set period (1-24 hours).
- To set Auto-Off: With the unit ON, press the TIMER button. Use TEMP+/- to set the desired hours. The unit will turn off after the set time.
- To set Auto-On: With the unit OFF, press the TIMER button. Use TEMP+/- to set the desired hours. The unit will turn on after the set time.
4.5 Ruwan Ruwa
The unit collects condensed water during operation. It has a self-evaporating system, but in high humidity, the water tank may fill up.
- Magudanar Manual: When the water tank is full, the unit will stop operating and display an indicator. Turn off the unit, place a shallow pan under the drain port, and remove the drain plug to empty the water.
- Cigaban magudanar ruwa: For continuous operation in high humidity, attach a drain hose (not included) to the continuous drain port and direct it to a floor drain or bucket.
5. Kulawa
Regular maintenance ensures efficient operation and extends the lifespan of your unit.
5.1 Tsaftace Tacewar iska
Ya kamata a tsaftace matatar iska kowane mako biyu ko fiye akai-akai dangane da amfani.
- Cire naúrar daga tashar wutar lantarki.
- Locate and remove the air filter from the rear of the unit.
- A wanke matatar a ƙarƙashin ruwan da ke gudana (ruwan dumi da sabulu idan datti ne sosai).
- A bar matatar ta bushe gaba ɗaya kafin a sake saka ta. Kar a fallasa ta ga hasken rana kai tsaye.
5.2 Tsabtace Waje
- Shafe wajen naúrar da taushi, damp zane.
- Kada a yi amfani da sinadarai masu tsauri, masu tsaftace muhalli, ko kuma masu ƙarfi.
5.3 Adana
Idan ana adana na'urar na tsawon lokaci:
- Drain all condensed water from the unit.
- Clean the air filter and allow it to dry.
- A kunna na'urar a yanayin fanka kawai na tsawon awanni kaɗan don busar da kayan ciki.
- Cire igiyar wutar lantarki da murɗa shi da kyau.
- Ajiye naúrar a wuri mai sanyi, busasshen wuri, zai fi dacewa a cikin marufi na asali.
6. Shirya matsala
Before contacting customer support, try these common troubleshooting steps.
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| Naúrar baya kunna | No power; Power cord unplugged; Circuit breaker tripped; Water tank full. | Check power connection; Plug in securely; Reset circuit breaker; Drain water tank. |
| Naúrar baya sanyaya yadda ya kamata | Air filter dirty; Exhaust hose blocked/kinked; Room too large; Doors/windows open; Temperature setting too high. | Clean air filter; Check and straighten exhaust hose; Close doors/windows; Lower temperature setting. |
| Unit yana hayaniya | Naúrar ba a kan madaidaici ba; Tace datti; Toshewa a fan. | A sanya a kan wuri mai faɗi; Tsaftace matatar iska; Duba ko akwai cikas. |
| Zubar ruwa | Drain plug loose; Unit tilted; Continuous drain hose not properly connected. | Ensure drain plug is secure; Place unit on level surface; Check continuous drain hose connection. |
| Ikon nesa baya aiki | Batteries dead; Obstruction between remote and unit; Remote too far. | Replace batteries; Remove obstructions; Move closer to unit. |
Lambobin Kuskure:
- FL (Full Water): The internal water tank is full. Drain the water as described in Section 4.5.
- E1 (Temperature Sensor Error): Unplug the unit for 5 minutes and plug it back in. If the error persists, contact support.
- E2 (Coil Temperature Sensor Error): Unplug the unit for 5 minutes and plug it back in. If the error persists, contact support.
7. Ƙayyadaddun bayanai
Technical specifications for the Inventum AC901 Portable Air Conditioner.
| Siffar | Ƙayyadaddun bayanai |
|---|---|
| Sunan Samfura | AC901 |
| Alamar | Ƙaddamarwa |
| Girma (L x W x H) | 33 x 28 x 68 cm |
| Nauyin Abu | 0.12 kilogiram (Note: This weight may be a data entry error and typically refers to packaging weight. Actual unit weight is significantly higher.) |
| Watatage | 1000 watts |
| Voltage | 240 Volts |
| Tushen wutar lantarki | Corded Electric |
| Matsayin Surutu | 65db ku |
| Siffofin Musamman | Idle Wheel, Integrated display, Remote Controlled |
| Ayyuka | Sanyaya, Dumamawa, Rage Danshi |
8. Garanti da Tallafawa
Inventum products are manufactured to the highest quality standards. This product comes with a standard manufacturer's warranty against defects in materials and workmanship from the date of purchase.
For warranty claims, technical support, or service inquiries, please contact your retailer or the Inventum customer service department. Please have your model number (AC901) and proof of purchase ready when contacting support.
Bayanin hulda:
(Please refer to your purchase documentation or the official Inventum website for specific contact details in your region.)