Akozon TS-FT002

Akozon TS-FT002 Ultrasonic Water Level Sensor and Temperature Display User Manual

Model: TS-FT002 | Brand: Akozon

1. Gabatarwa

The Akozon TS-FT002 is an ultrasonic water level sensor designed to monitor the liquid depth in a tank and display it on a 10-element liquid crystal bar graph. This device also provides simultaneous indoor and tank temperature readings. It supports high/low liquid level alarms and an empty tank alert, offering convenient monitoring for various non-corrosive liquid storage applications.

2. Kayan Samfura

  • Monitors liquid depth in tanks and displays it on a 10-element LCD bar graph.
  • Records minimum and maximum liquid levels.
  • Features high/low liquid level alarms and an empty tank alert.
  • Displays both indoor temperature and tank temperature concurrently.
  • The receiver unit can be placed on a desk or mounted on a wall.

3. Abubuwan Kunshin

Da fatan za a duba kunshin don abubuwa masu zuwa:

  • 1 x Ultrasonic Water Level Sensor (Transmitter)
  • 1 x Indoor Receiver Display Unit
  • 2 x Masu Haɗawa

Note: Batteries are not included. Please prepare 2 x AA 1.5V alkaline batteries for the receiver and 6 x AAA 1.5V lithium batteries for the transmitter.

4. Ƙayyadaddun bayanai

SiffarƘayyadaddun bayanai
Yankin Yanayin Yanayi Na Cikin Gida0 ~ 60 ° C
Yanayin Zazzabi Na Waje-40 ~ 60 ° C
Daidaiton Zazzabi± 1 °C
Water Level Measurement Range0 ~ 15m ku
Water Level Resolution0.01 m
Water Level Accuracy+/- 0.03 m
Mitar watsawa433 MHz
Nisa Watsawa100 m (in open area)
Tazarar watsawa30 seconds (level change) / 3 minutes (level stable)
Batirin Mai karɓa2 x AA 1.5V LR3 Alkaline (not included)
Batirin watsawa6 x AAA 1.5V LR6 Lithium (not included)
Rayuwar Batirin Mai karɓaKimanin watanni 12
Rayuwar Batir Mai watsawaMafi qarancin watanni 12
Girman Mai karɓa108 x 94 x 27 mm
Girman Mai watsawa97 x 68 x 152 mm
Girman allo na LCD66 x 45 mm
Liquid masu dacewaAny non-corrosive liquid
Yin hawaReceiver: Desk-standing or Wall-mount
Fasaha SahihiUltrasonic

5. Bangaren Ƙasaview

Receiver Display with Labeled Components

Receiver display with labeled components

This image shows the receiver unit's display with various indicators and buttons labeled for easy identification.

  1. Value display area
  2. Tank temperature and water level icon
  3. Water level unit
  4. Tank temperature unit (°C/°F)
  5. Mai nuna alamar batir a waje
  6. Alarm activation icon
  7. Min. and max. indicator icon
  8. Empty alert icon
  9. Alamar siginar RF
  10. Tank level high and low alarm indicator
  11. Water tank depth icon
  12. Alamar ƙararrawa lokaci
  13. Time and alarm value area
  14. Indoor temperature value display area
  15. Indoor temperature unit

Detailed LCD Display Description

Detailed LCD display description with numbered indicators

This diagram provides a comprehensive breakdown of all indicators and segments on the LCD screen.

  1. Tank Level Display
  2. Feet/Meters Unit
  3. Temperature Unit (°C/°F)
  4. High Alarm Indicator
  5. Low Alarm Indicator
  6. Ƙarfin Siginar RF
  7. Min/Max Record Indicator
  8. Empty Tank Alert
  9. Cikakkiyar Alamar Tanki
  10. 10-Segment Bar Graph for Water Level
  11. Water Level Percentage
  12. Nunin Lokaci
  13. Alamar AM/PM
  14. Nunin Zazzabi na cikin gida
  15. Indoor Temperature Unit (°C/°F)
  16. Home Icon (Indoor)

Sensor and Receiver Units

Akozon TS-FT002 ultrasonic sensor and receiver unit side-by-side

This image displays the complete Akozon TS-FT002 system, showing the ultrasonic sensor (transmitter) and the indoor receiver unit.

Sensor Installation Example

Ultrasonic sensor installed on top of a water tank, showing wireless signal transmission to the receiver

An illustration of the ultrasonic sensor correctly installed on a water tank, demonstrating its wireless communication with the receiver unit.

Sensor Balance Bubble

Kusa view of the ultrasonic sensor's top, showing the balance bubble for level installation

A close-up of the ultrasonic sensor's top, highlighting the integrated balance bubble to ensure a level and accurate installation.

Receiver Rear View

Na baya view of the receiver unit, showing battery compartment and wall-mount slots

The back of the receiver unit, showing the battery compartment cover, wall-mounting slots, and product information including the model number TS-FT002.

Girman samfur

Dimensions of the ultrasonic sensor and receiver unit

This image provides the physical dimensions of both the ultrasonic sensor (transmitter) and the receiver unit for installation planning.

Installation Sketch and Examples

Setup sketch illustrating transmitter installation and examples of incorrect installations

A detailed diagram showing the correct method for installing the transmitter, along with visual examples of common incorrect installation scenarios to avoid.

6. Saita Umarnin

6.1. Shigar da Baturi

  1. Unit mai karɓa: Open the battery compartment on the back of the receiver. Insert 2 x AA 1.5V alkaline batteries, ensuring correct polarity. Close the compartment.
  2. Transmitter Unit (Sensor): Open the battery compartment on the sensor unit. Insert 6 x AAA 1.5V lithium batteries, observing correct polarity. Close the compartment securely to maintain water resistance.

6.2. Transmitter (Sensor) Installation

The transmitter should be installed on top of the tank, directly above the liquid surface, ensuring a clear path for the ultrasonic signal. Refer to the 'Installation Sketch and Examples' image for visual guidance.

  • Wuri: Choose a location on the tank where the sensor can be mounted vertically and stably. Avoid areas with obstructions directly below the sensor that could interfere with the ultrasonic beam.
  • Matsayi: Use the integrated balance bubble on the top of the sensor to ensure it is perfectly level. An unlevel installation can lead to inaccurate readings.
  • Share: Ensure there is at least 0.5 meters (H1) of clear space between the sensor and the maximum liquid level. The sensor should also be at least 20 cm (R) away from the tank walls or any internal structures to prevent false readings.
  • hawa: Secure the transmitter using the provided screws or other suitable mounting hardware. Ensure it is firmly attached and will not shift.
  • Nau'in Ruwa: This sensor is suitable for any non-corrosive liquid. Do not use with corrosive substances.

6.3. Receiver Unit Placement

Place the receiver unit indoors within the 100-meter transmission range of the transmitter. Consider the following:

  • Ƙarfin Sigina: Position the receiver where it can receive a strong RF signal from the transmitter. Walls and other obstacles can reduce the effective range.
  • Ganuwa: Place the receiver in a location where the display is easily visible for monitoring.
  • hawa: The receiver can stand on a flat surface (e.g., desk) using its integrated stand or be mounted on a wall using the slots on its back.

7. Umarnin Aiki

7.1. Initial Power-On and Synchronization

Once batteries are installed in both units, they should automatically attempt to synchronize. The receiver's display will show the current liquid level and temperatures after successful synchronization.

7.2. Karatun Nuni

Nunin LCD yana ba da bayanai masu zuwa:

  • Matsayin Liquid: Shown as a numerical value (in meters) and a 10-segment bar graph.
  • Yanayin Tanki: The temperature of the liquid in the tank.
  • Zazzabi na cikin gida: The ambient temperature at the receiver's location.
  • Lokaci: Nunin lokaci na yanzu.
  • Alamar siginar RF: Shows the strength of the wireless connection.
  • Alamomin baturi: Alerts for low battery in either the receiver or transmitter.

7.3. Kafa larararrawa

The device allows setting high and low liquid level alarms, as well as an empty tank alert. Refer to the receiver's buttons (SET, MAX/MIN, TANK, ALARM) for navigation and adjustment. Detailed programming steps are typically found in the full product manual, but generally involve:

  1. Danna maɓallin Ƙararrawa button to cycle through alarm settings.
  2. Amfani SET or other navigation buttons to adjust the desired high/low level thresholds.
  3. Confirming settings to activate the alarms.

7.4. Min/Max Records

The device automatically records the minimum and maximum liquid levels. Press the MAX/MIN button to view these recorded values.

8. Kulawa

  • Madadin Baturi: Replace batteries in both the receiver and transmitter units when the low battery indicator appears on the display. Ensure to use the specified battery types (AA for receiver, AAA for transmitter).
  • Tsaftacewa: Wipe the receiver display and sensor unit with a soft, dry cloth. Do not use abrasive cleaners or immerse the units in water.
  • Duban Sensor: Periodically inspect the transmitter unit for any debris or buildup that might obstruct the ultrasonic sensor. Clean gently if necessary.
  • Yanayin Muhalli: Ensure the transmitter is not exposed to extreme conditions beyond its operating temperature range (-40 ~ 60 °C) or corrosive environments.

9. Shirya matsala

  • Babu Nuni/Iko: Duba ko an shigar da batura daidai kuma suna da isasshen caji. A maye gurbin idan ya cancanta.
  • No Signal/Inaccurate Readings:
    • Ensure the transmitter and receiver are within the 100m range and there are no major obstructions (e.g., thick walls) between them.
    • Verify the transmitter is installed level using the balance bubble.
    • Check for obstructions directly below the sensor inside the tank.
    • Ensure the sensor is not too close to the tank walls (minimum 20cm clearance).
    • Confirm the liquid is non-corrosive.
    • If the tank has a high dome (e.g., 60cm), ensure the sensor is positioned correctly to avoid measuring the tank entrance rim instead of the liquid surface.
  • Difficulty with Programming/Settings: The programming interface can be complex. Refer to the detailed instructions in the complete product manual for specific button sequences and menu options.
  • Alarms Not Triggering: Check that the high/low alarm thresholds are set correctly and are within the expected operating range.

10. Garanti da Tallafawa

For warranty information and technical support, please refer to the documentation provided with your purchase or contact Akozon customer service through their official channels. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.