Elitech LogEt 6 Logger Data Logger

Umurni na kariya da kiyayewa
Umarnin aminci
To ensure that you install and use this product correctly, please read and strictly comply with the following terms:
Baturi
- Please use original or technically compatible batteries. Do not use batteries that do not meet product specifications to prevent damage to equipment or other malfunctions.
- Do not disassemble, squeeze, hit, or heat batteries privately, and do not place batteries in fire, as this may cause battery explosions and fires
Rashin wutar lantarki na waje:
- When external power supply is required, please use the power adapter configured for this device.
- Do not use other power adapters that do not meet the external connection technical specifications, otherwise it may damage the instrument and equipment, and even cause a fire power supply.
Kayan aiki
- In flammable and explosive gas environments, please use this equipment in accordance with compliance requirements; otherwise, it may cause explosions and fires
- During the use of the device, if the device emits a burnt or other odor, the power supply should be immediately cut off and the manufacturer or supplier should be contacted in a timely manner
Hankali
- If the equipment is not used for a long time, it should be removed and stored in the packaging box in a dry and cool environment
- Users are not allowed to make any unauthorized changes to this device. Any unauthorized changes may affect the accuracy of the device and even damage it
- Kar a yi amfani da na'urar a wurare masu tsauri don guje wa gajerun da'ira, konewa, da sauran lahani da ke haifar da mummunan yanayi kamar ruwan sama da walƙiya.
- When the recorder is offline (no data upload), please confirm the networking status of the device
- Please use within the measurement range of the recorder
- Please mistakenly place the external probe directly in a liquid environment to avoid equipment damage
- Please do not forcefully impact this recorder
- The measured values of the recorder may be affected by the following factors
Kuskuren zafin jiki
Placed in the measurement environment for too short a stable time Close to heat sources, cold sources, or directly in a water soaked state
Humidity error
- Placed in the measurement environment for too short a stable time
- Long term exposure to steam, water mist, water curtains, or condensation environments
Gurbacewa:
- Being in a dusty or other polluted environment
Samfurin Ƙarsheview da Bayyanar
LogEt 6 is a disposable dry ice recorder with a built-in probe. Equipped with ultra-low temperature sensors as standard, the entire machine can directly record temperature in an environment of -85 ° C. It can export reports or automatically generate PDF files through data center software, with 16000 sets of storage, 30 days of battery life, 2 years of shelf life, and support for shadow data function before and after. Widely used in freezers, medical insulation boxes, laboratories, and other scenarios.
- Kebul na USB
- LED
- LCD allon
- Maɓallin tsayawa
- Maɓallin farawa
- External probe interface (reserved)
- Mai riƙe batir

- max/min/avr/MTK/log quantity
- babba iyaka
- ƙananan iyaka
- yanayin aiki
- matakin baturi
- Temperature/humidity values
- kwanan wata
- lokaci
Model list and specifications
Jerin Lissafi
| Samfura | LogEt 6 |
| daidaitawa | PT |
| probe Type | Built in ultra-low temperature (dry ice) |
| Main sensor parameters | zafin jiki firikwensin |
| Ma'aunin zafin jiki | -85 ℃ ~ 50 ℃ |
| Ma'aunin zafin jiki daidaito | ±0.5℃(-20℃~40℃);±1℃(other) |
| Ƙimar zafin jiki | 0.1 ℃ |
Ƙayyadaddun bayanai
| Ƙarfin ajiya | 16000 |
| Bayanan bayanai | USB A |
| Baturi | LS14250 lithium battery |
| Rayuwar rayuwa | 2 Shekaru |
| Rayuwar baturi | 30Days(log interval5min) |
| Communication module/mode | Kebul na USB |
| Matsayin kariya | IP65 |
| Product dimensions (height*length*width) | 100*46*19mm |
| Nauyi | 60 g |
| Yanayin aiki | -85˚C~50˚C |
| Maɓallan jiki | Fara/Dakata |
| Hanyar ƙararrawa | LED |
| Adaptation software | Elitechlog |
Umarnin aiki
Maɓalli ayyuka
Start button: In normal display mode, press the start button to display the current temperature, and continue pressing to switch temperature data, date and time, number of records, maximum value, and minimum value; Press and hold for 5 seconds to start recording; Stop button: Long press for 5 seconds to stop recording;
Legend status indication

Software aiki
Zazzage software
Download and install the “Jingchuang Data Center” software www.e-elitech.com/xiazaizhongxin (China), www.elitechlog.com/software (wasu kasashe)
Karanta bayanai
- Connect the computer using a USB interface
- Open the “Jingchuang Data Center” and wait for the link to complete.
- Open the PDF file directly on my computer or open the summary/historical data of “Jingchuang Data Center” to view data.
Bayanan kula
Data can be directly read without the need for the “Jingchuang Data Center” software After the device is taken out of a low-temperature environment, it needs to be left to stand for a period of time and wait for it to return to room temperature before the LCD screen displays data
Fitar da bayanai
Click on Summary/Historical Data, select Export Data, and choose the format to export
Jerin kayan haɗi
- Host * 1, instruction manual (electronic version), calibration certificate (electronic version)
Garanti da sabis na tallace-tallace
Garantin samfur: 1 shekara
This product can be returned, replaced or repaired within 7 days from the date of purchase due to performance failure. The warranty period is one year from the date of purchase (based on valid purchase receipts). During the warranty period, any malfunctions caused by quality problems of the product under normal use will be repaired free of charge. The shipping cost for repairing the product shall be borne unilaterally by the sender.
If any of the following situations are met, it is not within the scope of the after-sales guarantee:
- Damage caused by force majeure, such as earthquakes, fires, floods, typhoons, etc;
- Damage caused by human factors, such as improper use, maintenance, and storage by consumers.
- Damage caused by maintenance, disassembly, etc. by non-precision service personnel or authorized service providers;
- Exceeding the warranty period and scope;
- Natural wear and tear, consumption, and aging of products (such as shells, cables, etc.).
FAQs
Tambaya: Menene zan yi idan na'urar tana fitar da wani sabon wari?
A: Immediately disconnect the power supply and contact the manufacturer or supplier for assistance.
Tambaya: Ta yaya zan fara yin rikodi akan na'urar?
A: Press and hold the Start button for 5 seconds to initiate recording.
Takardu / Albarkatu
![]() |
Elitech LogEt 6 Logger Data Logger [pdf] Jagoran Jagora 01, 02, LogEt 6 Logger Data Logger, LogEt 6. |