1. Gabatarwa
This manual provides detailed instructions for the proper setup, operation, and maintenance of your Hayear HY-500B 5MP USB Digital Industrial Microscope Camera. This high-quality digital microscope system is designed for precise observation and analysis in various industrial applications, including phone repair, PCB chip welding, and other intricate tasks. Please read this manual thoroughly before using the device to ensure optimal performance and longevity.
2. Abubuwan Kunshin
Tabbatar cewa duk abubuwan da aka haɗa suna cikin kunshin ku:
- 1 x 5.0MP Microscope Camera (Model: HY-500B)
- 1 x USB Cable (1.5 Meter length)
- 1 x Software DISC
- 1 x 150X C-Mount Lens
- 1 x Table Stand with LED Light
- 1 x Power Adapter (EU, AU, US, or UK type, as applicable)
This image shows all components of the Hayear HY-500B microscope kit, including the camera, 150X C-mount lens, table stand with LED lights, USB cable, and software disc.
3. Ƙayyadaddun bayanai
3.1. 5.0MP Microscope Camera (HY-500B)
| Siffar | Bayani |
|---|---|
| Samfura | HY-500 |
| Sensor | 5MP, Micron 1/2.5 inch Color CMOS Image Sensor |
| Rage Tsari | 180 NM - 500 NM |
| Girman Girma | 500X & Under |
| Still Captured Resolution | 2592x1944 (5MP) |
| Image Output Format | MJPEG / YUV2 (YUYV) |
| Frame Rate (MJPEG) | 5MP: 2592x1944 HDR @ 30fps; 3MP: 2084x1536 HDR @ 30fps; 2MP: 1920x1080 HDR @ 30fps; 2MP: 1600x1200 HDR @ 30fps; 1MP: 1280x720 HDR @ 30fps |
| Girman Pixel | 2.2μm (H) x 2.2μm (V) |
| Tsarin Bidiyo | MP4 |
| Tsarin Hoto | JPEG, BMP |
| Taimakon Interface | DirectShow, TWAIN, SDK, Redistributable |
| Shirye-shiryen Shirye-shiryen | Brightness, Contrast, Saturation, Hue, Sharpness, Gamma, Gain, White Balance, Backlight Contrast, Exposure |
| Farin Ma'auni | Auto/Manual, One-click support |
| Ikon fallasa ta atomatik | Auto/Manual |
| Martanin Spectral | 400nm~1000nm |
| Rage Rage | 74 dB (Linear) / 85 dB (HDR) |
| SNR | 39db ku |
| Hankali | 2400 mV/Lux-sec |
| Fitowar Hoto | USB2.0, 480Mb/s |
| Direban Tallafi | USB Video Class (UVC) - Driver-free |
| Tsarin Aiki | WIN8 / SP4 / XP / VISTA / WIN7 / WIN10 / WIN11 |
| Yanayin Aiki | -35°C ~ 75°C |
| Tsawon Waya | 1.5 Meter (USB) |
| Kayan abu | Karfe |
| Takaddun shaida | CE, FCC, RoHS |
3.2. 150X C-Mount Lens
- Working Distance: 50mm - 350mm
- Filin View: 3.1mm - 66mm
- Zoom Ratios: 5:1
- Magnification Power: 0.11X - 2X
- Size: 100mm (Length) * 28mm (Diameter)
This image displays the 150X C-Mount lens, a key component for magnification.
3.3. Table Stand with LED Light
- Ring Diameter (for camera/lens attachment): 35mm
- Microscope High Pillar: 21cm
- Base Size: 17cm x 11cm
- Nauyin Abu: 600g
- Abu: Aluminum Alloy
This image shows the sturdy table stand with adjustable LED lights, designed to hold the microscope camera and lens.
4. Saita Umarnin
Follow these steps to assemble and set up your Hayear HY-500B microscope camera:
- Haɗa Tsaya: Place the microscope stand base on a stable, flat surface. Ensure the vertical pillar is securely attached.
- Attach the Camera to the Stand: Insert the 5.0MP Microscope Camera into the ring holder on the stand. Tighten the adjustment knob to secure the camera in place.
- Install the 150X C-Mount Lens: Carefully screw the 150X C-Mount Lens onto the camera's C-mount interface.
- Haɗa Fitilun LED: Position the flexible LED lights as needed for optimal illumination of your working area. Connect the power adapter to the stand's power input and plug it into an electrical outlet.
- Haɗa zuwa Kwamfuta: Connect the USB cable from the camera's USB port to an available USB 2.0 port on your computer.
- Shigar da Software: Insert the provided Software DISC into your computer's optical drive. Follow the on-screen instructions to install the necessary drivers and viewing software. If your computer lacks an optical drive, please contact support for alternative software download options.
This image shows the main camera unit, ready for lens attachment and mounting on the stand.
This image highlights the USB port on the rear of the camera, where the USB cable connects to the computer.
This image shows the front of the camera, where the C-mount lens is attached.
5. Aiki
Once the hardware is assembled and software installed, you can begin using your microscope camera:
- Kaddamar da Software: Open the installed microscope viewing software on your computer.
- Adjust Focus and Magnification: Place the object you wish to observe on the stand's base. Use the focus knob on the stand to adjust the distance between the lens and the object until a clear image appears on your computer screen. The 150X C-Mount lens allows for a magnification range of 0.11X - 2X, with a working distance of 50mm-350mm.
- Illuminate the Object: Adjust the flexible LED lights to provide optimal illumination for your specimen.
- Software Controls: Utilize the software interface to control various image parameters such as brightness, contrast, saturation, hue, sharpness, gamma, gain, white balance (Auto/Manual/One-click), and exposure (Auto/Manual).
- Ɗaukar Hotuna/Bidiyo: The software will allow you to capture still images (JPEG, BMP) and record videos (MP4) of your observations. Refer to the software's help documentation for specific instructions on capturing media.
This image demonstrates the superior pixel rendering of the HY-500B compared to similar products, showcasing its high-resolution capabilities for detailed observation.
6. Kulawa
- Tsaftace Lens: Use a soft, lint-free cloth and a specialized lens cleaning solution to gently clean the lens surfaces. Avoid touching the lens with bare fingers.
- Cleaning the Camera Body and Stand: Wipe the camera body and stand with a dry, soft cloth. For stubborn dirt, a slightly damp cloth can be used, but ensure no moisture enters the electronic components.
- Ajiya: When not in use, store the microscope in a clean, dry environment, away from direct sunlight and extreme temperatures. Use the lens cap to protect the lens from dust.
- Sabunta software: Lokaci-lokaci bincika masana'anta website for any software or driver updates to ensure optimal performance and compatibility.
7. Shirya matsala
If you encounter issues with your Hayear HY-500B microscope, refer to the following common problems and solutions:
- Babu Hoto akan Allo:
- Tabbatar cewa kebul na USB yana da haɗin tsaro da kyamara da kwamfuta.
- Verify that the microscope software is running and the correct camera device is selected.
- Check if the camera's drivers are correctly installed (refer to Section 4. Setup Instructions).
- Restart the computer and the software.
- Hoton yana da duhu:
- Adjust the focus knob on the stand to bring the object into sharp focus.
- Ensure the object is within the working distance range of the 150X C-Mount lens (50mm-350mm).
- Clean the lens if there is any dust or smudges.
- Insufficient Illumination:
- Ensure the power adapter for the stand is connected and plugged in.
- Adjust the position and brightness of the LED lights.
- Software Not Recognizing Camera:
- Reinstall the software and drivers from the provided DISC or the manufacturer's website.
- Try connecting the camera to a different USB port on your computer.
- Ensure your operating system is compatible (WIN8 / SP4 / XP / VISTA / WIN7 / WIN10 / WIN11).
8. Tukwici masu amfani
Babu takamaiman shawarwarin mai amfani da aka samu daga sakeviews or Q&A for this product at this time. For best results, ensure proper lighting and stable positioning of your samples.
9. Garanti da Tallafawa
Your Hayear HY-500B microscope camera is designed for reliability and performance. For any support needs, please refer to the following information:
- Komawa Kyauta: The product is eligible for free returns within 90 days of purchase.
- Garantin Isar da Sauri: In case of delayed delivery, a coupon code may be provided. Refunds are available if the package is lost or items are damaged during transit, or if delivery is not made within 30 days.
- DOA (Dead On Arrival) Products: If you receive a DOA product, please contact customer support immediately. You may be asked to provide images or videos to prove the condition. Upon confirmation, a full refund will be arranged.
- Taimakon Fasaha: For any technical questions or issues not covered in this manual, please contact the HAYEAR Direct-sale Store Store customer service. All products are tested before shipping. If you receive any DOA shipments, please contact us first instead of opening disputes. We will respond within 24 hours to assist you.