Gabatarwa
This manual provides essential information for the safe and effective use of the Enersys Cyclon 0800-0004 X-Cell 2 Volt/5 Amp Hour Sealed Lead Acid Battery. This pure lead sealed lead acid battery is designed for general applications such as emergency lighting, UPS systems, and electronic equipment.
Key features of the Cyclon battery include:
- Yawan Wuta: Offers high-rate power density per unit weight, allowing for more energy-supporting features.
- Rayuwar Zagayowar: Provides 50% to 200% greater full cycle capability compared to competitive lead products, delivering up to 300 cycles (100% DOD, C/5).
- Float Life: Designed for a ten-year life at 25°C, C/5, to 80% of rated capacity.
- High Stable Voltage Delivery: Achieved through low internal resistance, providing a flat discharge voltagda profile similar to Nickel Cadmium.
- Tsaro: Emits minimal to no gassing under normal charging conditions, making it safe for installation in various environments.

Hoto 1: Gaba view of the Enersys Cyclon 0800-0004 X-Cell battery, showing the brand name, model, and key specifications.

Figure 2: Diagram illustrating the internal components of a Cyclon Single Cell, including the resealable safety valve, pure lead plates, AGM plate separator, and steel can enclosure.
Saita da Shigarwa
Proper setup is crucial for the optimal performance and longevity of your Enersys Cyclon battery. Follow these guidelines carefully:
1. Binciken Farko
Upon receiving the battery, inspect it for any signs of physical damage. Ensure the terminals are clean and free from corrosion. Do not use the battery if it appears damaged.
2. Yanayin Muhalli
Install the battery in a clean, dry, and well-ventilated area. Avoid locations with extreme temperatures, direct sunlight, or high humidity. The recommended operating temperature range is typically between -65°C to +80°C, but optimal performance and float life are achieved around 25°C.
3. Ka'idojin Haɗi
Connect the battery to your equipment using appropriate cables and connectors. Ensure correct polarity: connect the positive (+) terminal of the battery to the positive terminal of your device, and the negative (-) terminal to the negative terminal. Incorrect polarity can damage the battery and connected equipment.

Hoto 3: Sama view of the Enersys Cyclon battery, showing the positive and negative terminals for connection.
4. Cajin Farko
While Cyclon batteries are shipped with a charge, it is recommended to fully charge the battery before its first use, especially if it has been stored for an extended period. Use a charger specifically designed for sealed lead-acid batteries with a 2-volt output. Refer to the charger's instructions for proper charging procedures.
Umarnin Aiki
The Enersys Cyclon battery is designed for reliable performance in various applications. Observe the following during operation:
1. Discharge Characteristics
The Cyclon battery provides a high stable voltage delivery due to its low internal resistance. This results in a flat discharge voltagda profile, ensuring consistent power output throughout its discharge cycle. Avoid deep discharges below the recommended voltage levels to maximize battery life.
2. Charging During Operation
For applications requiring continuous power, the battery can be kept on a float charge. Ensure the charging voltage is within the manufacturer's specified range for 2-volt sealed lead-acid batteries to prevent overcharging or undercharging.
3. Kariyar Tsaro
Although Cyclon batteries are sealed and non-spillable, always handle them with care. Do not short-circuit the terminals. Avoid exposing the battery to open flames or excessive heat. Ensure proper ventilation if the battery is enclosed, even though gassing is minimal under normal conditions.
Kulawa
Enersys Cyclon batteries are maintenance-free due to their sealed, non-spillable design. However, periodic checks can help ensure optimal performance and longevity:
1. Terminal Inspection
Periodically check the battery terminals for cleanliness and tight connections. Clean any dust or dirt with a dry cloth. Do not use abrasive cleaners or solvents.
2. Adana
If the battery is to be stored for an extended period, ensure it is fully charged before storage. Store in a cool, dry place away from direct sunlight and extreme temperatures. Recharge the battery every 6-9 months during storage to prevent self-discharge and maintain capacity.
3. Zubar da Batir
Do not dispose of the battery in household waste. Sealed lead-acid batteries contain recyclable materials and should be recycled according to local regulations. Contact your local recycling center for proper disposal instructions.
Shirya matsala
This section addresses common issues you might encounter with your Enersys Cyclon battery.
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| Baturi baya riƙe caji | Undercharging; End of life; Internal damage | Ensure charger is compatible and functioning correctly. Fully charge the battery. If issue persists, battery may need replacement. |
| Ƙara girmatage fitarwa | Battery discharged; Loose connections; Overload | Recharge the battery. Check and tighten all connections. Ensure the load does not exceed battery capacity. |
| Baturi baya caji | Faulty charger; Incorrect connection; Battery fault | Verify charger functionality with another battery or device. Check polarity and connections. If battery is severely discharged, it may not accept charge. |
If you experience issues not listed here or if the suggested solutions do not resolve the problem, please contact Enersys customer support.
Ƙayyadaddun bayanai
Detailed specifications for the Enersys Cyclon 0800-0004 X-Cell Battery:
- Lambar Samfura: 0800-0004
- Nau'in Baturi: Lead Acid (SLA)
- Voltage: 2 Volts
- Iyawa: 5 Amp Awanni (Ah)
- Girman samfur: 1.75 x 1.75 x 3.21 inci
- Nauyin Abu: 12.8 oz
- Mai ƙira: Enersys
- Kwanan Wata Farko Akwai: Yuni 18, 2004
- Abubuwan Amfani: Emergency lighting, UPS systems, electronic equipment
Tsaro da Gargaɗi
Please read and understand all safety warnings before handling or using the battery.

Figure 4: Warning label on the Enersys Cyclon battery, including Proposition 65 warning and other safety symbols.
Shawara 65 Gargaɗi
GARGADI: Battery posts, terminals, and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and reproductive harm. Batteries also contain other chemicals known to the State of California to cause cancer. Wash hands after handling.
Gabaɗaya Kariyar Tsaro
- Risk of fire, explosions or burns. Do not disassemble, heat above 80°C or incinerate.
- Follow product charging instructions.
- Do not charge in sealed container.
- Always wear appropriate personal protective equipment (PPE) such as safety glasses and gloves when handling batteries.
- A kiyaye batura daga wurin yara.
- In case of accidental contact with battery contents, flush with water immediately and seek medical attention.
Garanti da Taimako
For warranty information, please refer to the documentation provided with your purchase or contact Enersys directly. The manufacturer's warranty typically covers defects in materials and workmanship under normal use.
Bayanin Tuntuɓar Mai ƙira:
Enersys Energy Products Inc.
Warrensburg, MO 64093-9301
Waya: (610) 208-1991
Website: www.enersys.com
For full list of the warning and precautionary statements and applicable SDS sheet, please visit the Enersys website.