Eltako KR09-12V/UC

Eltako KR09-12V UC Coupling Relay User Manual

Model: KR09-12V/UC | Brand: Eltako

1. Gabatarwa

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Eltako KR09-12V UC Coupling Relay. Please read these instructions carefully before using the device and retain them for future reference. The Eltako KR09-12V UC is a coupling relay designed for various electrical switching applications, featuring a nominal voltage of 230V and a maximum switching current of 2A with one normally open (NO) contact.

2. Umarnin Tsaro

3. Samfurin Ya Ƙareview

The Eltako KR09-12V UC is a compact coupling relay designed for reliable switching operations in various control circuits. It features a single normally open (NO) contact and is rated for a nominal voltage of 230V with a maximum switching current of 2A. Its screw terminals ensure secure electrical connections.

Eltako KR09-12V UC Coupling Relay

Hoto na 1: Eltako KR09-12V UC Coupling Relay. This image displays the compact design of the relay, highlighting its terminals and housing.

Mabuɗin fasali:

4. Ƙayyadaddun bayanai

SiffarDaraja
Mai ƙiraEltako
Lambar SamfuraKR09-12V/UC
Girma (L x W x H)10 x 5 x 1 cm
Nauyi40 Grams
Voltage230 V
Coil Voltage12V (DC)
Max. Canjawa Yanzu2 A
Ƙarfi240 Watts
Nau'in Tuntuɓi1 Bukatu na al'ada (NO)
Abubuwan TuntuɓiCopper
Nau'in HaɗiScrew Terminals
Yanayin AikiNa atomatik
Takaddun shaidaCULus, VDE
Amfani da NiyyaProfessional and Domestic Use

5. Saita da Shigarwa

The Eltako KR09-12V UC coupling relay is designed for fixed installation. Due to the electrical nature of this device, installation must be carried out by a qualified electrician in accordance with all applicable national and local electrical codes and regulations.

  1. Kashe Haɗin Wuta: Before commencing any installation work, ensure that the main power supply to the circuit is completely disconnected and secured against accidental re-connection.
  2. hawa: Mount the relay in a suitable enclosure or on a DIN rail, ensuring adequate ventilation and protection from environmental factors.
  3. Haɗin Waya: Connect the relay using the screw terminals. Refer to the wiring diagram provided with the product packaging for specific connection points. Ensure all connections are tight and secure to prevent loose contacts and potential hazards.
  4. Coil Voltage: Connect the 12V DC control voltage zuwa tashoshin na'urar relay coil.
  5. Haɗin Load: Connect the load circuit to the normally open (NO) contact terminals. Ensure the load voltage and current do not exceed the relay's ratings (230V, 2A).
  6. Tabbatarwa: After wiring, double-check all connections for correctness and security.
  7. Maido da Wuta: Restore power to the circuit and test the relay's functionality.

Note: Incorrect installation can lead to device malfunction, electrical shock, or fire.

6. Umarnin Aiki

The Eltako KR09-12V UC coupling relay operates automatically based on the control signal applied to its coil. When the 12V DC coil voltage is present, the normally open (NO) contact will close, completing the load circuit. When the 12V DC coil voltage is removed, the NO contact will open, breaking the load circuit.

7. Kulawa

The Eltako KR09-12V UC coupling relay is designed for long-term, maintenance-free operation under normal conditions. However, periodic inspection is recommended to ensure optimal performance and safety.

Note: Do not attempt to open or repair the relay yourself. Refer to qualified personnel for any repairs.

8. Shirya matsala

If you encounter issues with your Eltako KR09-12V UC coupling relay, consider the following common troubleshooting steps:

MatsalaDalili mai yiwuwaMagani
Relay does not activate (contact does not close)No 12V DC coil voltage; Incorrect wiring; Faulty relay coil.Check 12V DC supply to coil terminals; Verify wiring against diagram; Replace relay if coil is faulty.
Relay activates but load does not receive powerLoad circuit wiring error; Faulty load; Overload protection tripped; Damaged relay contact.Check load circuit wiring; Test the load independently; Check circuit breakers/fuses; Replace relay if contact is damaged.
Relay remains activated (contact stays closed)Coil voltage not removed; Contact welded shut due to overload.Ensure 12V DC coil voltage is correctly removed; Replace relay if contacts are welded.
Overheating or unusual odorsOverload; Loose connections; Internal fault.Immediately disconnect power. Check load current; Tighten all connections; Replace relay if internal fault is suspected.

If the problem persists after performing these steps, contact a qualified electrician or Eltako customer support for further assistance.

9. Garanti da Tallafawa

Eltako products are manufactured to high-quality standards. This product comes with a stated spare parts availability of 1 year. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Eltako website.

For technical support, inquiries, or to report a fault, please contact your local Eltako distributor or visit the Eltako official website don bayanin lamba.