Gabatarwa
The Technoline WS 9140-IT is a temperature station designed for monitoring both indoor and outdoor temperatures. It features a DCF-77 radio-controlled clock for automatic time synchronization, an alarm with snooze function, and records minimum and maximum temperature values. This device can be conveniently placed on a table or mounted on a wall.
Abubuwan Kunshin
Please check that all components are present in the package:
- 1 x WS 9140-IT Base Station
- 1 x TX37-IT Outdoor Sensor
- Jagorar mai amfani (wannan takaddar)
Samfurin Ƙarsheview
The Technoline WS 9140-IT consists of a main base station and a wireless outdoor sensor. The base station displays time, indoor temperature, and outdoor temperature. It also features control buttons for settings and functions.

Hoto na 1: Technoline WS 9140-IT Temperature Station and its packaging.

Hoto na 2: Gaba view of the base station and the outdoor sensor, showing display elements and technical specifications.
Base Station Display Elements:
- Nunin Lokaci: Shows current time, synchronized via DCF-77 radio signal.
- Zazzabi na cikin gida: Displays the temperature measured by the base station.
- Zazzabi na waje: Displays the temperature received from the wireless sensor.
- MIN/MAX Indicators: Shows recorded minimum and maximum temperatures.
- Alamar baturi: Alerts when batteries are low.
Maɓallan sarrafawa:
- SAITA: Enters setting mode.
- ADAM: Activates/deactivates alarm and enters alarm setting mode.
- MIN/MAX RESET: Displays minimum/maximum values and resets them.
- '+' / '-': Adjusts values during setting or changes display options.
Saita
1. Shigar da Baturi
For the Outdoor Sensor (TX37-IT):
- Open the battery compartment cover on the back of the outdoor sensor.
- Insert 2 x AA Mignon LR06 batteries, observing the correct polarity (+/-).
- Rufe murfin ɗakin baturi amintacce.
For the Base Station (WS 9140-IT):
- Open the battery compartment cover on the back of the base station.
- Insert 2 x AA Mignon LR06 batteries, observing the correct polarity (+/-).
- Rufe murfin ɗakin baturi amintacce.
Note: Always insert batteries into the outdoor sensor first, then into the base station to ensure proper synchronization.
2. Sanya Sensor
Place the outdoor sensor in a shaded, dry location, protected from direct sunlight and rain, to ensure accurate temperature readings. The maximum transmission distance is 100 meters in open air. Avoid placing it near large metal objects or electrical appliances that may interfere with the signal.
3. Initial Synchronization (DCF-77 Radio Clock)
After battery installation, the base station will automatically begin searching for the DCF-77 radio signal. This process may take several minutes. Once the signal is received, the time will be set automatically. A radio tower icon will appear on the display, indicating successful synchronization.
4. Manual Time Setting (Optional)
If the radio signal is not available or if you prefer to set the time manually:
- Latsa ka riƙe SET button har sai da sa'a lambobi flash.
- Yi amfani da '+' or '-' maɓalli don daidaita sa'a.
- Latsa SET sake tabbatarwa da kuma matsawa zuwa saitin mintuna.
- Amfani '+' or '-' don daidaita minti.
- Latsa SET to confirm and exit manual time setting.
5. Daidaita Yankin Lokaci
To adjust for different time zones (± 12 hours):
- A cikin yanayin nuni na al'ada, latsa ka riƙe SET button har sai da sa'a lambobi flash.
- Latsa SET repeatedly until the time zone offset (e.g., '00') flashes.
- Yi amfani da '+' or '-' buttons to adjust the time zone offset.
- Latsa SET don tabbatarwa da fita.
Umarnin Aiki
1. Reading Temperature
The current indoor and outdoor temperatures are continuously displayed on the base station's screen.
2. Minimum/Maximum Temperature Recording
The station automatically records the minimum and maximum indoor and outdoor temperatures since the last reset.
- Danna maɓallin MIN/MAX RESET button once to display the maximum recorded temperatures.
- Danna maɓallin MIN/MAX RESET button a second time to display the minimum recorded temperatures.
- Latsa ka riƙe MIN/MAX RESET button to clear the recorded minimum and maximum values. The display will show the current temperatures, and new min/max values will begin recording.
3. Alarm Setting and Snooze Function
Saita Ƙararrawa:
- Danna maɓallin Ƙararrawa button once to display the alarm time.
- Latsa ka riƙe Ƙararrawa maɓallin har sai lambobi na ƙararrawa suna walƙiya.
- Yi amfani da '+' or '-' maɓalli don daidaita sa'ar ƙararrawa.
- Latsa Ƙararrawa again to confirm and move to alarm minute setting.
- Amfani '+' or '-' to adjust the alarm minutes.
- Latsa Ƙararrawa don tabbatarwa da fita saitin ƙararrawa.
Kunna / Kashe Ƙararrawa:
- A cikin yanayin nuni na al'ada, danna maɓallin Ƙararrawa button repeatedly to toggle the alarm ON or OFF. An alarm icon will appear on the display when the alarm is active.
Aiki na Snooze:
- When the alarm sounds, press any button (except Ƙararrawa) to activate the snooze function. The alarm will sound again after approximately 5 minutes.
- Domin dakatar da ƙararrawar gaba ɗaya, danna maɓallin Ƙararrawa button when it is sounding.
4. Ma'anar Ƙarfin Baturi
A low battery icon will appear on the display when the batteries in either the base station or the outdoor sensor need to be replaced. Replace all batteries promptly to ensure continuous operation and accurate readings.
Kulawa
1. Madadin Baturi
When the low battery indicator appears, replace the batteries in both the base station and the outdoor sensor. Use 2 x AA Mignon LR06 batteries for each unit. Ensure correct polarity during installation.
2. Tsaftacewa
Wipe the units with a soft, damp zane. Kada a yi amfani da masu tsaftace goge-goge ko masu narkewa, domin waɗannan na iya lalata nuni ko casing. Ensure the units are dry before re-inserting batteries or operating.
Shirya matsala
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| No outdoor temperature display or '---' | No signal from outdoor sensor; Batteries in sensor are low or incorrectly inserted; Sensor too far from base station or obstructed. | Check sensor batteries and polarity. Move sensor closer to base station. Avoid obstructions like thick walls or metal objects. Re-synchronize by removing and re-inserting batteries in both units (sensor first). |
| Nunin lokacin da ba daidai ba | DCF-77 signal not received; Incorrect time zone setting. | Ensure base station is placed away from electronic interference. Allow time for automatic synchronization. Manually set time or adjust time zone if necessary. |
| Nuni ba shi da duhu ko sarari | Low batteries in base station. | Replace batteries in the base station. |
| Ƙararrawa baya yin sauti | Alarm is not activated; Alarm time is incorrectly set. | Ensure the alarm icon is visible on the display. Verify the alarm time setting. |
Ƙayyadaddun bayanai
- Samfura: WS 9140-IT
- Alamar: Technoline
- Base Station Dimensions (L x W x H): 73 x 25 x 158 mm
- Outdoor Sensor Dimensions (L x W x H): 38 x 21 x 128 mm
- Base Station Power: 2 x AA Mignon LR06 batteries (not included)
- Outdoor Sensor Power: 2 x AA Mignon LR06 batteries (not included)
- Matsakaicin Zazzabi na cikin gida: -10°C zuwa +40°C
- Matsayin Zazzabi na Waje: -40°C zuwa +60°C
- Mitar watsawa: 868 MHz
- Nisan Watsawa: Har zuwa mita 100 (bude filin)
- Siffofin Musamman: DCF-77 Radio-controlled clock, Manual time setting option, Time zone adjustment (± 12 h), MIN/MAX temperature memory, Alarm with snooze function, Low battery indicator, Wall mount or table stand.
- Abu: Filastik

Hoto na 3: The Technoline WS 9140-IT base station can be wall-mounted for convenient viewing.
Garanti da Taimako
Specific warranty information and detailed support contacts are not provided in the product data. For warranty claims or technical assistance, please refer to the documentation included with your purchase or contact the retailer where the product was acquired. You may also visit the official Technoline website for general support information.





