1. Gabatarwa
The Altronix R2416300UL is a rack mount power supply designed to provide 24VAC or 28VAC power for various applications, particularly commercial CCTV equipment. This unit features 16 individually fused outputs, ensuring reliable power distribution and protection. It is housed in a durable steel enclosure and includes a line cord, spare fuse, removable terminal blocks, and mounting brackets for convenient installation.
2. Muhimman Bayanan Tsaro
Please read these safety instructions carefully before installing or operating the Altronix R2416300UL power supply. Failure to follow these instructions may result in electric shock, fire, or damage to the unit.
- Hadarin Girgizar Wutar Lantarki: Do not open the unit. Refer all servicing to qualified service personnel.
- Sauya Fuse: For continued protection against fire, replace all fuses with the same type and rating (3.5A, 250V).
- Yanayin Muhalli: Do not expose the unit to rain or moisture. Install in a dry, indoor location.
- Samun iska: Tabbatar da isasshen iska a kusa da naúrar don hana zafi fiye da kima.
- Kasa: Tabbatar cewa na'urar ta yi daidai da ƙa'idodin wutar lantarki na gida.
- Tushen wutar lantarki: Connect the unit only to a 115VAC, 60Hz power source.

Hoto 1: Gaba view of the Altronix R2416300UL Rack Mount Power Supply. This image shows the black steel enclosure with the Altronix logo and 16 green LED indicators for each output. A caution label for electric shock is visible on the right.
3. Saita da Shigarwa
3.1. Ana kwashe kaya
Carefully remove the power supply from its packaging. Verify that all components are present: the R2416300UL unit, line cord, spare fuse, removable terminal blocks, and mounting brackets.
3.2. Hawaye
The R2416300UL is designed for rack mounting. Use the provided mounting brackets to secure the unit into a standard 19-inch equipment rack. Ensure the rack is stable and provides adequate support for the unit's weight (approximately 17.2 pounds).
3.3. Input Power Connection
- Ensure the power switch on the rear of the unit is in the "OFF" position.
- Connect the supplied line cord to the AC input receptacle on the rear of the power supply.
- Plug the other end of the line cord into a grounded 115VAC, 60Hz power outlet.

Hoto 2: Na baya view of the Altronix R2416300UL Rack Mount Power Supply. This image displays the power switch, AC input, and the array of 16 output terminal blocks. The product label with specifications is also visible.
3.4. Haɗin Fitarwa
The R2416300UL provides 16 individually fused 24VAC or 28VAC outputs. Each output is equipped with a removable terminal block for easy wiring.
- Identify the desired output terminal block (labeled 1 through 16).
- Connect your device's power input wires to the corresponding terminals on the removable block. Ensure correct polarity if applicable to your device.
- Securely insert the wired terminal block into its receptacle on the power supply.
- Repeat for all devices requiring power.

Figure 3: Close-up of the rear product label and output terminal blocks. This image provides a detailed view of the product specifications, safety warnings, and the green removable terminal blocks for connecting output devices.
4. Umarnin Aiki
4.1. Kunnawa / Kashewa
- To power on the unit, flip the power switch on the rear panel to the "ON" position.
- To power off the unit, flip the power switch on the rear panel to the "OFF" position.
4.2. Output Indicators
The front panel of the R2416300UL features 16 green LED indicators, one for each output. A lit green LED indicates that the corresponding output is receiving power and the fuse is intact.

Figure 4: Close-up of the front panel showing the 16 green LED indicators. Each LED corresponds to an individual fused output, providing a visual status of power delivery.
5. Kulawa
5.1. Kulawar Gabaɗaya
- Keep the unit clean and free from dust. Use a dry, soft cloth for cleaning.
- Tabbatar cewa ba a toshe buɗewar samun iska.
5.2. Sauya Fuse
If an output LED is off, the corresponding fuse may be blown. To replace a fuse:
- Kashe Wuta: Disconnect the unit from the main power supply by unplugging the line cord.
- Identify Blown Fuse: Locate the fuse holder for the affected output on the rear panel.
- Remove Fuse: Carefully remove the blown fuse.
- Shigar da Sabon Fis: Replace it with a new fuse of the exact same type and rating: 3.5A, 250V. Using an incorrect fuse can cause damage or fire.
- Dawo da Power: Reconnect the unit to the main power supply and turn it on. Verify the output LED illuminates.
6. Shirya matsala
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| No power to the unit (no LEDs lit). |
|
|
| One or more output LEDs are off. |
|
|
| Unit powers on, but connected devices do not function. |
|
|
7. Ƙayyadaddun bayanai
| Siffar | Daki-daki |
|---|---|
| Alamar | Altronix |
| Lambar Samfura | R2416300UL |
| Shigar da Voltage | 115VAC (Minimum 110V, Maximum 115V) |
| Mitar shigarwa | 60 Hz |
| Fitarwa Voltage | 24VAC ko 28VAC |
| Output Current (24VAC) | 12.5 A |
| Output Current (28VAC) | 10 A |
| Number of Fused Outputs | 16 |
| Fuse Type/Rating | 3.5 A, 250V |
| Factor Factor | Rashin Dutsen |
| Kayayyakin Rufe | Karfe |
| Gama | Baki |
| Girman samfur (L x W x H) | 19.13 x 8.5 x 3.27 inci |
| Nauyin Abu | 17.2 fam |
| Matsayi | UL 2044 Commercial CCTV, CUL, CE |
| Hanyar sanyaya | Iska |
8. Garanti da Tallafawa
8.1. Garanti Bayani
Altronix products are typically backed by a limited lifetime warranty. For specific warranty terms and conditions applicable to your R2416300UL unit, please refer to the official Altronix website ko tuntuɓi sabis na abokin ciniki kai tsaye. Ajiye rasidin siyan ku azaman shaidar siyan.
8.2. Tallafin Fasaha
For technical assistance, installation questions, or troubleshooting beyond the scope of this manual, please contact Altronix technical support. You can find their contact information on the official Altronix webshafin (www.altronix.com).