Madison M5000

Jagoran Jagora

Madison M5000 Liquid Level Sensor

Samfurin Ƙarsheview

The Madison M5000 is a miniature float switch designed for reliable liquid level detection. Constructed from 316 stainless steel, it is suitable for a wide range of applications, including those requiring superior corrosion resistance, high temperatures, or use in medical, petrochemical, and food processing environments. This sensor detects high or low liquid levels within a container.

Madison M5000 Liquid Level Sensor

Hoto na 1: Madison M5000 Liquid Level Sensor. This image shows the stainless steel float switch with its threaded stem and electrical lead wires extending from the top. The main body is cylindrical, designed to float or sink with liquid levels.

Bayanin Tsaro

Before installation and operation, read and understand all instructions. Failure to do so may result in product damage, property damage, or personal injury. Ensure all electrical connections comply with local and national electrical codes. Disconnect power before installing or servicing the sensor.

  • Do not exceed the maximum pressure and temperature ratings of 300 PSI and 392°F (200°C).
  • Ensure the sensor is rated for the specific liquid and environment it will be used in.
  • Switches are rated for resistive loads. Refer to UL guidelines for current (Amperes resistive) at different voltage.

Saita da Shigarwa

The M5000 sensor is designed for vertical mounting using its 1/8" NPT thread. It can be installed to detect either high or low liquid levels depending on its orientation.

Hanyar hawa:

  • Normally Open (NO) Operation: For high-level detection, mount the sensor so the float is at the bottom and rises with the liquid. The switch will close when the liquid reaches the float.
  • Normally Closed (NC) Operation: For low-level detection, mount the sensor so the float is at the top and falls with the liquid. The switch will open when the liquid drops below the float.

Matakan Shigarwa:

  1. Identify the desired mounting location in the container, ensuring it is clean and free of debris.
  2. Thread the 1/8" NPT stem into the appropriate port. Use a suitable sealant (e.g., PTFE tape) on the threads to ensure a leak-proof seal. Do not overtighten.
  3. Connect the 24", 22 AWG Teflon insulated lead wires to your control circuit. Refer to the electrical specifications for appropriate voltage da kuma halin yanzu ratings.
  4. Verify the float moves freely without obstruction within the container.

Ka'idojin Aiki

The Madison M5000 operates on a simple magnetic principle. Inside the stainless steel stem, there is a hermetically sealed reed switch. The float, which contains a magnet, moves along the stem as the liquid level changes. When the magnet in the float comes into proximity with the reed switch, it causes the switch contacts to open or close, signaling the liquid level status to the connected control system.

The float has a specific gravity (SG) of 0.70, meaning it will float in liquids with an SG greater than 0.70. For liquids with an SG less than 0.70, the float will sink, and the sensor's operation will be inverted.

Kulawa

The Madison M5000 liquid level sensor is designed for minimal maintenance due to its robust stainless steel construction. However, periodic inspection is recommended to ensure optimal performance.

  • Tsaftacewa: If the sensor is used in applications with viscous or particulate-laden liquids, the float and stem may accumulate residue. Periodically clean the float and stem to ensure free movement. Use cleaning agents compatible with 316 stainless steel.
  • Dubawa: Check the lead wires for any signs of damage or wear. Ensure the NPT connection remains secure and leak-free.
  • Gwajin Aiki: If possible, periodically test the sensor's operation by manually raising or lowering the liquid level (or simulating it) to confirm the switch activates correctly.

Shirya matsala

MatsalaDalili mai yiwuwaMagani
Sensor not activating
  • Waya mara daidai
  • Float obstructed or stuck
  • Liquid specific gravity too low
  • Damaged reed switch
  • Verify wiring against electrical diagram.
  • Inspect and clean float/stem for obstructions.
  • Ensure liquid SG is > 0.70 for standard operation.
  • Test switch continuity; replace if faulty.
Intermittent readings
  • Sakkun hanyoyin haɗin lantarki
  • Jijjiga
  • Danko ruwa
  • Bincika kuma amintar duk hanyoyin haɗin waya.
  • Ensure stable mounting; consider anti-vibration measures.
  • Clean float and stem.
Leakage at mounting point
  • Improper thread sealant
  • Rashin isasshen matsewa
  • Lalacewar zaren
  • Reapply appropriate thread sealant.
  • Tighten connection to recommended torque (without overtightening).
  • Inspect threads for damage; replace sensor or fitting if necessary.

Ƙayyadaddun bayanai

SigaDaraja
Lambar SamfuraM5000
Abun kara316 Bakin Karfe
Abubuwan Tafiya316 Bakin Karfe
Float Specific Gravity (SG)0.70
Zaren Hauwa1/8" NPT
Matsin lamba300 PSI
Matsakaicin Zazzabi392F (200°C)
Canja Rating30 Watt, SPST (Single Pole, Single Throw)
Ƙimar Lantarki
  • 240 VAC, 0.14A
  • 120 VAC, 0.28A
  • 120 VDC, 0.07 A
  • 24 VDC, 0.28 A
Wayoyin gubar24", 22 AWG, Teflon Insulated
AmincewaCE, UL, NSF
Girman samfur9.06 x 6.3 x 7.09 inci; 1.6 oz

Note: Switches are rated for resistive loads. Refer to UL guidelines for current (Amperes resistive) at different voltage.

Bayanin Garanti

Specific warranty details for the Madison M5000 Liquid Level Sensor are typically provided at the point of purchase or can be obtained directly from Madison Company. Please retain your proof of purchase for warranty claims.

Taimako da Tuntuɓi

For technical assistance, troubleshooting beyond this manual, or inquiries regarding parts and service, please contact Madison Company directly. Contact information can typically be found on the manufacturer's official website ko samfur marufi.

Manufacturer: Madison Company

Takardu masu alaƙa - M5000

Preview Madison FREESOUND-VR30 User Manual
User manual for the Madison FREESOUND-VR30 vintage radio, covering setup, operation, safety instructions, specifications, and disposal information.
Preview Madison FREESOUND-VR30 Rechargeable Vintage Radio with Bluetooth & FM - User Manual
This user manual provides comprehensive instructions for the Madison FREESOUND-VR30 vintage radio, covering safety guidelines, product features, operation, specifications, and proper disposal.
Preview Madison Custom Printed Information Guide: Logo Artwork, Post Measurement, and Colour Matching
Learn how to supply logo artwork, measure posts for custom printing, and match colours with Madison's comprehensive guide. Essential information for custom printed sports equipment and apparel.
Preview Madison MAD-MUSICA50 Bluetooth Party Speaker User Manual
Discover the features and operation of the Madison MAD-MUSICA50 Bluetooth Party Speaker with this comprehensive user manual. It provides detailed instructions, control explanations, and technical specifications in multiple languages for optimal use.
Preview Madison FREESOUND-VR40 Vintage Manual mai amfani da rediyo FM Bluetooth
Comprehensive user manual for the Madison FREESOUND-VR40 vintage radio, detailing features like Bluetooth, USB playback, FM radio, safety instructions, operation, and specifications.
Preview Madison Side Table Assembly Instructions
Step-by-step assembly guide for the Madison Side Table, including parts list, fittings, and detailed instructions for easy setup.