Dwyer A3000 Series

Littafin Umarnin Dwyer Photohelic Series A3000 Matsi/Ma'auni

Model: A3000 Series

1. Gabatarwa

The Dwyer Photohelic Series A3000 Pressure Switch/Gauge is a versatile instrument that combines the functions of a precise pressure gauge with highly repeatable pressure switches. Utilizing the proven Magnehelic gauge design, this device accurately measures and controls positive, negative, or differential pressures of air and compatible gases.

It features two phototransistor-actuated, DPDT relays for low/high limit control, allowing for precise system management. Set points are easily adjustable via knobs located on the gauge face. The continuous gauge reading remains unaffected by switch operation, even during power loss, ensuring reliable monitoring.

2. Features

  • Combined Functionality: Operates as both a pressure gauge and a pressure switch.
  • Precise Measurement: Employs the Magnehelic gauge design for accurate pressure readings.
  • Dual Control Relays: Includes two phototransistor-actuated DPDT relays for low/high limit control.
  • Adjustable Set Points: Easy-to-adjust set point indicators via front-mounted knobs.
  • Continuous Reading: Gauge reading is continuous and independent of switch operation or power status.
  • Optical Limit Switches: Utilizes optical limit switches for enhanced reliability and extended service life.
  • Variable Deadband: Set points can be interlocked to provide a variable deadband, suitable for fan or dampsarrafa ta.
  • Ƙarfafa Gina: Features a clear polycarbonate plastic cover and a light shield to protect internal components and ensure clear visibility.

3. Saita da Shigarwa

Proper installation is crucial for the accurate and reliable operation of your Photohelic Switch/Gauge. Refer to the detailed wiring diagrams and mounting instructions provided with your specific model for complete guidance.

3.1 Haɗawa

The unit is designed for vertical position calibration. Ensure the mounting surface is stable and free from excessive vibration. Secure the gauge using appropriate fasteners through the designated mounting holes.

3.2 Haɗin Matsi

Connect pressure lines to the appropriate ports on the gauge. Ensure all connections are sealed properly to prevent leaks, which can affect measurement accuracy. The gauge is suitable for air and compatible gases.

3.3 Haɗin Wutar Lantarki

Connect the power supply and control circuits to the DPDT relays as per the electrical schematic. Ensure all wiring complies with local electrical codes and safety standards. The optical limit switches are designed for reliability and precise switching accuracy.

Dwyer Photohelic Series A3000 Pressure Switch/Gauge with clear cover, showing internal components, gauge face, and control knobs.

Hoto na 1: Dwyer Photohelic Series A3000 Pressure Switch/Gauge. This image displays the device with its clear polycarbonate cover, revealing the internal circuitry, the pressure gauge face calibrated for vertical position, and the two set point adjustment knobs labeled "ZERO". The gauge face indicates a maximum pressure of 25 PSIG.

4. Aiki

4.1 Kunna Kunnawa

Once installed and wired, apply power to the unit. The gauge pointer will indicate the current pressure.

4.2 Sifili Daidaita

Before operation, ensure the gauge reads zero when no pressure is applied. Use the "ZERO" adjustment screw (typically located on the front cover or near the bottom of the gauge face) to calibrate the pointer to zero.

4.3 Setting Control Points

  1. Identify the two set point knobs on the front of the gauge. These control the low and high limit switches.
  2. Rotate the desired knob to move its corresponding red set point indicator to the required pressure value on the gauge face.
  3. When the actual pressure (indicated by the main pointer) crosses a set point indicator, the associated DPDT relay will actuate, triggering the connected control circuit.
  4. The individual set point deadband is approximately one pointer width, which is less than 1% of the full scale.
  5. For applications requiring a variable deadband, the set points can be interlocked according to specific wiring diagrams.

4.4 Reading the Gauge

The gauge provides a continuous visual indication of the measured pressure. The scale is typically in inches of water column (WC) or pounds per square inch (PSIG), depending on the model. For example, the gauge face shown in Figure 1 indicates a range up to 0.50 inches of water, with markings at .20, .30, .40, and .50.

5. Kulawa

The Dwyer Photohelic Switch/Gauge is designed for long-term, reliable operation with minimal maintenance. However, periodic checks are recommended.

  • Tsaftacewa: Keep the exterior of the gauge clean. Use a soft, damp cloth to wipe the clear cover. Avoid abrasive cleaners or solvents.
  • Duban Matsala: Periodically verify the zero point and accuracy of the gauge using a known pressure source. Recalibrate if necessary.
  • Mutuncin Haɗin kai: Inspect all pressure and electrical connections for tightness and signs of wear or corrosion.
  • Yanayin Muhalli: Ensure the operating environment remains within the specified temperature and humidity ranges to prevent damage to internal components.

6. Shirya matsala

If you encounter issues with your Photohelic Switch/Gauge, consider the following common troubleshooting steps:

  • No Gauge Reading:
    • Check pressure connections for leaks or blockages.
    • Verify that pressure is being applied to the correct ports.
  • Incorrect Gauge Reading:
    • Perform a zero adjustment.
    • Check for proper calibration against a known standard.
    • Ensure the gauge is mounted in a vertical position as calibrated.
  • Switches Not Actuating:
    • Verify electrical power to the unit.
    • Check wiring to the DPDT relays.
    • Ensure set points are correctly positioned relative to the current pressure.
    • Inspect optical limit switches for any obstructions or damage.
  • Aiki na wucin gadi:
    • Bincika madaidaicin haɗin wutar lantarki.
    • Tabbatar da ingantaccen wutar lantarki.
    • Verify environmental conditions are stable and within operating limits.

If problems persist, contact Dwyer technical support for assistance.

7. Ƙayyadaddun bayanai

SigaDaraja
Lambar SamfuraA3001AV (Specific model example)
Matsayin MatsiVarious, from 0-.25" WC up to 30 psi (21 bar); single positive pressure to 6000 psig (413 bar)
Max. Matsin AikiStandard models: 25 psig (1.7 bar); Options: 35 (2.4) or 80 (5.5 bar) psig; 36000S models: 6000 psig (413 bar)
Nau'in CanjawaTwo phototransistor actuated, DPDT relays
Saita Point DeadbandLess than 1% of full scale (one pointer width)
Dacewar MediaIska da iskar gas masu dacewa
Kayan abuPlastic (cover)
Nauyin AbuFam 4.7 (kimanin)
Mai ƙiraKayan Dwyer

8. Garanti da Tallafawa

For warranty information, technical support, or service inquiries, please contact Dwyer Instruments directly. Refer to the official Dwyer webshafin yanar gizo ko takardun siyan ku don cikakkun bayanai na yanzu da sharuɗɗan garanti.

Abubuwan da aka bayar na Dwyer Instruments, Inc.
www.dwyer-inst.com

Takardu masu alaƙa - Farashin A3000

Preview Dwyer Series A3000 Photohelic Differential Pressure Switch/Gage User Guide
User's guide for the Dwyer Series A3000 Photohelic Differential Pressure Switch/Gage, detailing its specifications, installation, electrical connections, and maintenance.
Preview Dwyer Magnehelic® Banbancin Matsalolin Matsi (HP/MP) - Ƙayyadaddun bayanai & Umarni
Ƙayyadaddun fasaha, shigarwa, da umarnin aiki don Dwyer's Magnehelic® High da Matsakaicin Matsalolin Matsaloli daban-daban Gages (Bulletin A-27-HP-MP). Ya haɗa da cikakkun bayanai na ƙira, daidaito, kewayon zafin jiki, hawa, haɗi, da na'urorin haɗi.
Preview Manometer ɗin Matsi Mai Bambancin Ruwa mara Waya na Dwyer Series 490W: Jagorar Shigarwa da Aiki
Cikakken jagora ga Dwyer Series 490W Wireless Hydronic Differential Pressure Manometer, wanda ya ƙunshi ƙayyadaddun bayanai, shigarwa, aiki, gyara matsala, da kulawa. Yana da na'urorin transducer mara waya don daidaita tsarin hydronic daidai.
Preview Dwyer Series 616KX Mai watsa Matsaloli daban-daban - Jagoran Fara Mai Sauri
Jagoran farawa mai sauri don Dwyer Series 616KX Mai watsa Matsalolin Matsaloli daban-daban, mai rufe hawa, wayoyi, da daidaita sifili. Ya haɗa da zane-zane na wayoyi don daidaitawar wayoyi 2 da 3-waya.
Preview Dwyer Series 616KX Jagoran Mai watsar da Matsalolin Matsaloli daban-daban
Jagorar mai amfani don Dwyer Series 616KX Mai watsa Matsalolin Matsaloli daban-daban, bayanin shigarwa, ƙayyadaddun bayanai, haɗin wutar lantarki, aiki, daidaita sifili, daidaita siginar fitarwa, taka tsantsan, kiyayewa, da bayanin garanti.
Preview Dwyer Series 616KX Jagoran Mai watsar da Matsalolin Matsaloli daban-daban
Jagorar mai amfani don na'urar watsawa ta Dwyer Series 616KX mai bambancin matsin lamba, wanda ya shafi shigarwa, ƙayyadaddun bayanai, haɗin lantarki, sifili daidaitawa, canje-canjen siginar fitarwa, matakan kariya, da bayanan garanti.