Dwyer WMT2-B-C-11-1

Ma'aunin Ruwa na Dwyer WMT2-BC-11-1 Mai Amfani da Manhajar Fitarwa ta Pulsed Output

1. Samfurin Ya Ƙareview

The Dwyer Series WMT2 Multi-Jet Water Meter is engineered for commercial and industrial applications requiring accurate water flow measurement. Its multi-jet design ensures reliable performance and accuracy across a broad range of flow rates, including low-flow conditions. The meter is built for durability and minimal maintenance, even in challenging environments. It features a magnetically driven, hermetically sealed register that prevents leaks and fogging, completely isolating it from the water flow. A reed switch, activated by a magnet on the dial, generates a pulsed output directly proportional to the flow rate. This output is suitable for remote monitoring of flow rate or totalization and can be integrated with PLCs, counters, data loggers, and SCADA systems.

Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter with Pulsed Output

Image 1.1: The Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter, showing its brass body, blue casing, and the meter face with a pulsed output connection.

2. Bayanin Tsaro

WARNING: This product is NOT FOR POTABLE WATER USE. The brass construction contains lead in excess of low-lead limits. Do not use this meter in applications where water will be consumed by humans or animals.

Always ensure proper installation by qualified personnel to prevent leaks and ensure accurate operation. Adhere to all local codes and regulations regarding plumbing and electrical connections.

3. Kayan Samfura

  • Multi-Jet Design: Provides high accuracy and wide flow range capabilities.
  • Pulsed Output: Equipped with a reed switch for remote monitoring and integration with control systems.
  • Hermetically Sealed Register: Magnetically driven, preventing leaks and fogging for clear readings.
  • Gina Mai Dorewa: Designed for long service life in commercial and industrial settings.
  • Brass Body: Robust construction for demanding applications.

4. Ƙayyadaddun bayanai

Ƙayyadaddun bayanaiDaraja
SamfuraWMT2-B-C-11-1
Girman Haɗawa1" BSPT
Matsakaicin Matsakaicin Ruwa7m³/h
Matsakaicin Gudun Gudun Suna0.25 zuwa 3.5 m³/h
Transitional Flow Rate0.07m³/h
Yawan Kabewa1 gallon per pulse
Matsakaicin Zazzabi104F (40°C)
Matsakaicin Matsi232 psi (16 mashaya)
Haɗin Wutar LantarkiColor-coded lead wires, 4.5' (1.5 m) long
Nauyin Abu13.52 fam
Mai ƙiraAbubuwan da aka bayar na Dwyer Instruments, Inc.

5. Saita da Shigarwa

Installation of the Dwyer WMT2-B-C-11-1 water meter should be performed by a qualified professional in accordance with all applicable local and national plumbing and electrical codes.

  1. Zaɓin Wuri: Choose a location that is easily accessible for reading and maintenance, protected from freezing temperatures, and where the meter can be installed horizontally with the flow arrow pointing in the direction of water flow.
  2. Pipe Preparation: Ensure the piping is clean and free of debris before installation. Use appropriate pipe thread sealant on the 1" BSPT couplings.
  3. Shigar Injini: Install the meter into the pipeline, ensuring a tight, leak-free connection. The meter should be installed in a straight run of pipe, ideally with at least 10 pipe diameters of straight pipe upstream and 5 pipe diameters downstream for optimal accuracy.
  4. Haɗin Wutar Lantarki: Connect the color-coded lead wires from the pulsed output to your remote monitoring system (PLC, counter, data logger, SCADA). Refer to your system's documentation for specific wiring requirements. Ensure all electrical connections are secure and properly insulated.
  5. Duban Leak: After installation, slowly open the water supply to the meter and check for any leaks at the connections.

6. Umarnin Aiki

Once installed and the water supply is restored, the Dwyer WMT2-B-C-11-1 meter will begin measuring water flow. The meter's register displays the totalized volume of water that has passed through it. The pulsed output provides an electrical signal (1 pulse per gallon) that can be used by external devices for remote monitoring and data logging.

  • Reading the Meter: The main display on the meter face shows the total accumulated volume. Smaller dials may indicate fractional units for more precise readings.
  • Pulsed Output: The reed switch generates a pulse for every gallon of water that flows through the meter. Connect the lead wires to a compatible device (e.g., PLC, counter) to record these pulses and calculate flow rate or total volume remotely.
  • Hanyar Tafiya: Ensure water flows in the direction indicated by the arrow on the meter body for accurate measurement.

7. Kulawa

The Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter is designed for relatively maintenance-free operation. However, periodic checks are recommended to ensure continued accuracy and performance:

  • Duban gani: Regularly inspect the meter for any signs of physical damage, leaks, or corrosion.
  • Register Clarity: Ensure the hermetically sealed register remains clear and free of fogging, allowing for easy reading.
  • Mutuncin Haɗin kai: Verify that all plumbing and electrical connections remain secure and free of corrosion.
  • Tsaftacewa: If the exterior of the meter becomes dirty, wipe it with a damp zane. Kada a yi amfani da sinadarai masu tsauri ko masu gogewa.

No internal user-serviceable parts are present. Do not attempt to disassemble the meter, as this will void the warranty and may damage the device.

8. Shirya matsala

If you encounter issues with your Dwyer WMT2-B-C-11-1 water meter, consider the following troubleshooting steps:

  • No Flow Reading:
    • Check if water is actually flowing through the pipe.
    • Verify the meter is installed with the flow arrow in the correct direction.
    • Inspect for any blockages upstream or downstream of the meter.
  • Karatuttukan da ba daidai ba:
    • Ensure the meter is installed horizontally.
    • Check for air in the pipeline, which can affect accuracy.
    • Verify that the flow rate is within the meter's specified nominal flow range.
  • No Pulsed Output:
    • Confirm that water is flowing through the meter and the mechanical register is advancing.
    • Check the electrical connections of the lead wires to your monitoring device.
    • Ensure the monitoring device is correctly configured to receive pulses.
  • Leaks a Connections:
    • Tighten connections carefully, ensuring not to overtighten.
    • If necessary, drain the system, reapply pipe thread sealant, and reassemble.

If problems persist after performing these checks, contact Dwyer Instruments, Inc. technical support for assistance.

9. Garanti da Tallafawa

For information regarding the product warranty, technical support, or replacement parts, please contact Dwyer Instruments, Inc. directly or visit their official website. Keep your purchase receipt and product model number (WMT2-B-C-11-1) readily available when seeking support.

Takardu masu alaƙa - WMT2-B-C-11-1

Preview Dwyer Series 477AV Manometer Dijital Na Hannu: Ƙayyadaddun bayanai, Shigarwa, da Umarnin Aiki
Cikakken jagora zuwa Dwyer Series 477AV Manometer Dijital Na Hannu, yana rufe ƙayyadaddun bayanai, shigarwa, umarnin aiki, fasali, da kiyayewa don matsa lamba, kwarara, da ma'aunin sauri.
Preview Dwyer Series IEF Shigar da Electromagnetic Flow Transmitter: Shigarwa da Umarnin Aiki
Wannan takaddar tana ba da cikakkun bayanai dalla-dalla, jagororin shigarwa, da umarnin aiki don Dwyer Series IEF Insertion Electromagnetic Flow Transmitter, dalla dalla dalla dalla dalla-dalla, aikace-aikace, da ka'idojin sadarwa don auna saurin ruwan masana'antu.
Preview Kayayyakin Aunawa da Sarrafa Guduwar Dwyer: Jagorar Zaɓa Mai Cikakkiyar Bayani
Bincika nau'ikan na'urorin auna kwarara, maɓallan kwarara, da na'urorin watsa kwarara na Dwyer Instruments. Wannan jagorar tana ba da cikakkun bayanai da ƙa'idodi na zaɓi don taimakawa wajen gano mafi kyawun samfurin don aikace-aikacen masana'antu ko kasuwanci.
Preview Jerin Dwyer VFC Visi-Float Flowmeters Mai Saurin Fara Jagora
Jagorar farawa mai sauri don Dwyer Series VFC Visi-Float Flowmeters, samar da mahimmancin shigarwa, hawa, da umarnin karantawa, tare da taka tsantsan aiki mai mahimmanci.
Preview Jerin Dwyer TUF Ultrasonic Energy Mita: Yawo da Kula da Zazzabi
Cikakkun bayanai dalla-dalla, fasali, aikace-aikace, da bayanan oda don Dwyer Series TUF Ultrasonic Energy Mita, wanda aka ƙera don ingantaccen kwarara da kula da zafin jiki tare da Modbus® ko sadarwar BACnet.
Preview Dwyer Process Automation Product Applications and Selection Guides
Explore Dwyer Instruments' comprehensive guide to process automation, covering product applications and selection for HVAC, water treatment, oil & gas, and more. Discover instrumentation solutions for pressure, flow, level, temperature, and air quality.