The MSA ALTAIR 4X Multi-Gas Detector is a robust and reliable instrument designed to monitor ambient air for the presence of combustible gases (LEL), Oxygen (O2), Carbon Monoxide (CO), and Hydrogen Sulfide (H2S). This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your device. Always read and understand these instructions before using the detector.

Muhimman Kariyar Tsaro:

MSA ALTAIR 4X Multi-Gas Detector showing display with gas readings

This image displays the MSA ALTAIR 4X Multi-Gas Detector, a compact, handheld device. The front panel features a large digital display showing readings for COMB/EX (combustible gases), O2 (oxygen), CO (carbon monoxide), and H2S (hydrogen sulfide). Above the display are control buttons and LED indicators. The device has a rugged, charcoal-colored casing.

Siffofin Samfurin da Abubuwan Haɓaka

The ALTAIR 4X is equipped with advanced MSA XCell sensors for rapid and accurate gas detection. Its robust design ensures durability in harsh environments.

Saita da Aikin Farko

1. Cire kaya da dubawa

Carefully remove the ALTAIR 4X detector from its packaging. Inspect the device for any visible damage. Ensure all components listed in the packing slip are present.

2. Cajin Baturi

Before first use, fully charge the detector's battery. Connect the charging cable to the detector and plug the charger into a power outlet. The charging indicator will show the charging status. A full charge typically takes several hours and provides up to 24 hours of operation.

3. Kunnawa / Kashewa

4. Initial Bump Test and Calibration

It is critical to perform a bump test before each day's use to verify sensor and alarm functionality. Full calibration should be performed regularly according to manufacturer recommendations and local regulations (e.g., every 3-6 months). Refer to the detailed calibration instructions provided with your calibration gas kit.

Yin aiki da Mai ganowa

1. Understanding the Display

The large LCD displays real-time gas concentrations for LEL, O2, CO, and H2S. It also shows battery status, alarm indicators, and other operational messages.

2. Alarm Conditions

The ALTAIR 4X features multiple alarm types:

When an alarm activates, immediately follow your company's safety protocols for hazardous gas exposure or emergency situations.

Worker wearing an MSA ALTAIR 4X Multi-Gas Detector clipped to their safety vest in an industrial setting

A worker is shown in an industrial environment, wearing an MSA ALTAIR 4X Multi-Gas Detector clipped to their safety vest, demonstrating typical usage.

Kulawa

Proper maintenance ensures the longevity and accuracy of your ALTAIR 4X detector.

1. Tsaftacewa

Clean the exterior of the detector regularly with a damp cloth. Do not use abrasive cleaners or solvents. Ensure sensor inlets are clear of debris.

2. Sensor Care

MSA XCell sensors are designed for durability, but proper care is essential. Avoid exposing sensors to extreme temperatures or prolonged high concentrations of gases outside their specified range, as this can reduce sensor life or cause damage.

3. Kula da baturi

To maximize battery life, avoid fully discharging the battery frequently. Store the detector in a cool, dry place when not in use, and ensure it is charged periodically if stored for long durations.

4. Adana

Store the detector in a clean, dry environment within the specified temperature range. Protect it from physical shock and direct sunlight.

Shirya matsala

This section addresses common issues you might encounter with your ALTAIR 4X detector.

MatsalaDalili mai yiwuwaMagani
Mai ganowa baya kunnawa.Low ko mataccen baturi.Cajin baturi cikakke.
Sensor error message displayed.Sensor fault, expired sensor, or calibration issue.Perform a bump test. If error persists, attempt calibration. If still unresolved, contact MSA support for sensor replacement.
Alarms not sounding/flashing.Alarm settings disabled, or speaker/LED fault.Check alarm settings in the menu. Perform a bump test to verify alarm function. If still no alarm, contact MSA support.
Inaccurate gas readings.Needs calibration, sensor contamination, or sensor nearing end-of-life.Perform a fresh air calibration, then a full calibration. Ensure sensor inlets are clean. If issues persist, sensor replacement may be required.

For issues not listed here or if solutions do not resolve the problem, please contact MSA customer support.

Ƙayyadaddun bayanai

SiffarDaki-daki
Lambar Samfura10107602
Gane GasLEL (Combustible), O2 (Oxygen), CO (Carbon Monoxide), H2S (Hydrogen Sulfide)
Tushen wutar lantarkiBattery Powered (24-hour battery life)
Nau'in larararrawaAudible, Visual (LED), Vibrating, Man-Down
Nau'in SensorMSA XCell Sensors
Ƙididdiga ta Ingress (IP).IP67
Sauke Juriya20-foot drop test certified
Tsawon Zazzabi Mai Aiki-4°F zuwa 122°F (-20°C zuwa 50°C)
Nauyin Abu0.55 Fam (kimanin oz 8.8)
Girman samfur10.39 x 5 x 3.94 inci (girman marufi)

Garanti da Taimako

The MSA ALTAIR 4X Multi-Gas Detector comes with a Garanti na shekaru 3 and a performance guarantee, ensuring reliability and peace of mind.

For technical support, warranty claims, or service, please contact MSA Safety Incorporated directly. Visit the official MSA webshafin don bayanin lamba da ƙarin albarkatu.