1. Gabatarwa
This manual provides detailed instructions for the installation, operation, and maintenance of your Taco 006-IQBC7-1IFC SmartPlus Hot Water Recirculation Pump. The SmartPlus system is designed to provide instant hot water at fixtures by intelligently monitoring and adapting to your household's hot water usage patterns, or by operating in a continuous pulse mode. Please read this manual thoroughly before installation and operation to ensure proper function and safety.
2. Muhimman Bayanan Tsaro
GARGAƊI: Rashin bin waɗannan umarnin tsaro na iya haifar da girgizar lantarki, gobara, mummunan rauni, ko mutuwa.
- Koyaushe ka cire wutar lantarki kafin a gyara famfon.
- Installation must be performed by a qualified plumber or electrician in accordance with all local codes and regulations.
- Do not operate the pump if the power cord is damaged.
- This pump is designed for hot water recirculation only. Do not use for other liquids or applications.
- Ensure the pump is properly grounded.
- Saka kayan kariya masu dacewa (PPE) yayin shigarwa da kulawa.
3. Abubuwan Kunshin
Tabbatar cewa duk abubuwan da aka gyara suna nan kafin fara shigarwa:
- Taco 006-IQBC7-1IFC SmartPlus Recirculation Pump
- Line Cord (pre-attached)
- Internal Check Valve (pre-installed)
- Jagoran Jagora
4. Umarnin Shigarwa
4.1 Jerin Lissafin Shigarwa
- Ensure the installation location is accessible for maintenance.
- Verify that the power supply matches the pump's requirements (115 Volts, 60 Hz).
- Confirm plumbing connections are ready for 1/2-inch sweat fittings.
- Turn off the main water supply and drain the hot water lines before proceeding.
4.2 Hawan famfo
The pump should be mounted in an accessible location, typically near the hot water heater or at the furthest fixture from the heater, depending on the system design. Ensure the pump is installed in a horizontal position with the motor above the volute to prevent air pockets.
4.3 Haɗin Ruwa
- Prepare the 1/2-inch copper pipes for sweat connections. Clean and flux the pipe ends and the pump's sweat ports.
- Solder the pump into the hot water recirculation line. Ensure a watertight seal.
- The pump includes an internal check valve to prevent backflow.
- After soldering, allow the connections to cool completely before restoring water pressure.
4.4 Haɗin Wutar Lantarki
The Taco SmartPlus pump comes with a pre-attached line cord for easy electrical connection.
- Ensure the power outlet is a standard 115V, 60Hz grounded receptacle.
- Plug the line cord into the dedicated electrical outlet.
- Kar a yi amfani da igiyoyin tsawo ko adaftan.

Figure 1: Taco SmartPlus Hot Water Recirculation Pump
This image displays the Taco SmartPlus hot water recirculation pump. The top section shows the control panel with LED indicators for 'SENSOR', 'MODE', and 'POWER', along with a 'TEMP SENSOR' port and the power cord connection. The main body of the pump features the 'Taco SmartPlus HOT WATER RECIRCULATION' logo and detailed specifications such as HP: 1/40, AMPS: 0.52, HZ: 60, VOLTS: 115, RPM: 3250, MAX PRESS: 125 PSI, MAX WATER TEMP: 104°C / 220°F. It also notes 'IMPEDANCE PROTECTED CONTINUOUS DUTY ENCLOSURE TYPE 2 / BOITIER DE TYPE 2 WATER CIRCULATING PUMP CLASS F' and 'TACO, INC. CRANSTON RI USA'.
5. Farko Saita da Kanfigareshan
5.1 Kunnawa
Once the pump is installed and plumbed, restore the main water supply and check for leaks. Then, plug in the pump's line cord to power it on.
5.2 Fahimtar Alamar LED
The control panel features three LED indicators:
- SENSOR LED: Indicates the status of the temperature sensor.
- LED MODE: Indicates the current operating mode (Smart Mode, Pulse Mode, or Vacation Mode).
- WUTA LED: Indicates that the pump is receiving electrical power.
5.3 Hanyoyin Aiki
The SmartPlus pump offers different operating modes to suit your needs. The mode can typically be selected via a button on the control panel (refer to specific product labeling if available).
- Yanayin Smart: The default and most energy-efficient mode. The pump learns your hot water usage patterns.
- Yanayin bugun jini: Provides continuous hot water by cycling the pump at regular intervals.
- Yanayin Hutu: An energy-saving mode for extended periods of inactivity.
6. Aiki
6.1 Smart Mode (Adaptive Recirculation)
In Smart Mode, the pump monitors and records your home's hot water usage pattern for the first seven days of operation. During the subsequent seven days, the SmartPlus repeats the preceding week's usage pattern to cycle the pump, ensuring instant hot water at all fixtures only when needed. This learning and repeating process is continuous, adapting every seven days to optimize efficiency and comfort.
6.2 Pulse Mode (Continuous Recirculation)
If selected, Pulse Mode sets the SmartPlus to run for 150 seconds every 10 minutes. This mode maintains hot water at all fixtures on a consistent schedule, regardless of learned usage patterns. This can be useful in situations where immediate hot water is always desired, or during periods of unpredictable demand.
6.3 Yanayin Hutu
The Vacation Function is designed to save energy during extended periods of absence. After 36 hours of inactivity (no hot water usage detected), the pump will automatically turn off. While in Vacation Mode, the pump will periodically cycle (Exercise Function) to prevent seizing and maintain system readiness. The pump will resume normal operation once hot water usage is detected again.
7. Kulawa
Regular maintenance ensures optimal performance and longevity of your SmartPlus pump.
- Binciken Shekara-shekara: Annually inspect the pump and plumbing connections for any signs of leaks, corrosion, or wear.
- Tsaftacewa: Keep the exterior of the pump clean and free from dust and debris. Do not use harsh chemicals.
- O-Ring Check: Na casing O-Ring (part number 007-003RP) should be inspected periodically and replaced if signs of wear or damage are present to prevent leaks.
- Harsashi taro: The cartridge assembly (part number 005-020RP) is a critical component. If the pump experiences reduced performance or unusual noises, consult a qualified technician for inspection or replacement.
- Lokacin hunturu: If the pump is installed in an unheated area subject to freezing temperatures, it must be drained and disconnected for winterization to prevent damage.
8. Jagorar Shirya matsala
Wannan sashe yana ba da mafita ga al'amuran gama-gari waɗanda zaku iya fuskanta.
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| No hot water at fixtures. | Pump not running; air in system; check valve issue; incorrect mode. | Check power connection and LED indicators. Bleed air from the system. Verify pump is in desired operating mode. |
| Pump baya kunnawa. | No power; faulty wiring; pump malfunction. | Check power outlet and circuit breaker. Ensure power cord is securely plugged in. If POWER LED is off, consult an electrician. |
| Pump runs continuously in Smart Mode. | Learning phase; sensor issue; constant hot water demand. | Allow 7 days for learning cycle. Check SENSOR LED. Ensure no constant hot water draw. |
| Pampo yana da hayaniya | Air in system; worn bearings; foreign object. | Bleed air from the system. If noise persists, contact technical support. |
| Leaks at connections. | Improperly soldered joints; worn O-ring. | Turn off water supply, drain, and re-solder connections. Inspect and replace O-ring if necessary. |
8.1 LED Indicator Troubleshooting
- Idan da LED WUTA is off, check the power supply.
- Idan da Yanayin LED is not indicating the expected mode, refer to the product's specific mode selection instructions.
- Idan da SENSOR LED indicates an error, ensure the temperature sensor is properly connected and functioning.
9. Bayanan fasaha
| Ƙayyadaddun bayanai | Daraja |
|---|---|
| Lambar Samfura | 006-IQBC7-1IFC |
| Horsepower (HP) | 0.025 (1/40) |
| Ampzamani (AMPS) | 0.52 |
| Voltage (VOLTS) | 115 |
| Mitar (HZ) | 60 |
| RPM | 3250 |
| Matsin lamba | 125 PSI |
| Yawan Zazzabin Ruwa | 104°C/220°F |
| Kayan abu | Tagulla |
| Haɗin kai | 1/2-Inch Sweat |
| Nauyin Abu | 6.24 fam |
| Girman samfur | 5 x 4 x 7 inci |
| Nau'in yadi | Farashin 2 |
| Cigaban Aikin | Ee |
| Ciki Duba Valve | Ee |
10. Garanti da Tallafawa
10.1 Bayanin Garanti
The Taco 006-IQBC7-1IFC SmartPlus Hot Water Recirculation Pump is covered by a Garanti mai iyaka na shekara 3 from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. For full warranty terms and conditions, please refer to the official Taco documentation or contact customer support.
10.2 Tallafin Fasaha
If you require technical assistance, have questions about installation, operation, or need to report a warranty claim, please contact Taco customer support. Have your model number and purchase date available when contacting support.
For further information, visit the official Taco webshafin ko tuntubi mai rarrabawa na gida.