This manual provides essential information for the safe and efficient use of your Philips Lighting ER55LD3WR LED Exit Sign. Please read these instructions carefully before installation and operation, and retain them for future reference. This product is designed for commercial lighting applications, specifically as a lighted exit sign.

Bayanin Tsaro

  • Always disconnect power before installing or servicing the unit.
  • Installation should be performed by a qualified electrician in accordance with national and local electrical codes.
  • Kada kayi amfani da wannan samfurin don wasu dalilai ban da abin da aka yi niyyar amfani dashi.
  • Tabbatar cewa duk hanyoyin haɗin suna amintacce kuma an killace su yadda ya kamata.
  • Ka nisantar da ruwa da yawan danshi.

Abubuwan Kunshin

Tabbatar cewa duk abubuwan da aka gyara suna nan kafin fara shigarwa:

  • Philips Lighting ER55LD3WR LED Exit Sign unit
  • Kayan aikin hawa (skru, anchors)
  • Manual Umarni (wannan takarda)

Saita da Shigarwa

The Philips Lighting ER55LD3WR LED Exit Sign is designed for wall mounting. Ensure the mounting surface is suitable to support the weight of the unit.

  1. Shirya Wurin Shigarwa: Disconnect power to the circuit where the exit sign will be installed.
  2. hawa:
    • Identify the desired wall mounting location.
    • Use the provided mounting hardware to securely attach the exit sign to the wall. Ensure the unit is level.
  3. Waya:
    • Connect the building's 120V AC power supply to the corresponding wires on the exit sign. Refer to the wiring diagram inside the unit's housing for specific connections.
    • Tabbatar da ƙasa mai kyau.
    • Connect the internal battery (if not pre-connected). This is crucial for emergency operation.
  4. Taron Karshe: Secure any covers or diffusers.
Philips Lighting ER55LD3WR LED Exit Sign, front view

Hoto 1: Gaba view of the Philips Lighting ER55LD3WR LED Exit Sign. This image shows the white housing with the red "EXIT" lettering illuminated, indicating its primary function as an emergency egress indicator.

Umarnin Aiki

Once installed and power is restored, the Philips Lighting ER55LD3WR LED Exit Sign will operate automatically.

  • Aiki na al'ada: When AC power is present, the "EXIT" sign will be illuminated by the internal LEDs. The green indicator light on the unit will be ON, signifying operating status.
  • Aikin Gaggawa: In the event of an AC power failure, the unit will automatically switch to battery backup, illuminating the "EXIT" sign for a specified duration (typically 90 minutes).
  • Maballin Gwaji: A test button is provided on the unit to verify emergency operation. Press and hold the "Push to Test" button to simulate an AC power failure. The sign should remain illuminated, and the green indicator light will blink, indicating testing. Release the button to return to normal operation.
Philips Lighting ER55LD3WR LED Exit Sign, test button and indicator lights

Hoto 2: Rufewa view of the test button and indicator lights on the Philips Lighting ER55LD3WR LED Exit Sign. The green indicator shows operating status (ON for ready, Blinking for testing). The red indicator shows service alerts such as battery, charger board, transformer, or LED strip faults.

Kulawa

Regular maintenance ensures the reliability and longevity of your LED Exit Sign.

  • Gwajin wata-wata: Press the "Push to Test" button for at least 30 seconds to ensure the battery backup system is functioning. The sign should remain illuminated.
  • Gwaji na Shekara-shekara: Disconnect AC power to the unit for 90 minutes to verify the battery can sustain emergency illumination for the required duration.
  • Tsaftacewa: Tsaftace wajen naúrar da taushi, damp zane. Kada a yi amfani da masu tsabtace abrasive ko sauran ƙarfi.
  • Madadin Baturi: The internal battery has a limited lifespan. If the unit fails to hold a charge or the red "Battery fault" indicator illuminates, the battery may need replacement. Contact qualified service personnel for battery replacement.

Shirya matsala

Koma zuwa tebur mai zuwa don batutuwan gama gari da mafitarsu.

MatsalaDalili mai yiwuwaMagani
Sign does not illuminate (AC power present)No AC power; faulty wiring; LED strip faultCheck circuit breaker; verify wiring connections; contact service for LED replacement.
Sign does not illuminate during power outage (emergency mode)Battery not connected; discharged battery; faulty battery; charger board faultEnsure battery is connected; allow 24 hours for initial charge; replace battery; contact service for charger board repair.
Red Service Alert indicator is ONIndicates battery, charger board, transformer, or LED strip fault (refer to unit label)Identify specific fault from unit label; perform monthly/annual tests; contact qualified service personnel.
Green Operating Status indicator is OFF (AC power present)No AC power; internal faultCheck AC power supply; contact qualified service personnel.

Ƙayyadaddun bayanai

SiffarDaki-daki
Lambar SamfuraER55LD3WR
AlamarPhilips Lighting
Nau'in Tushen HaskeLED
Voltage120 Volts
Tushen wutar lantarkiCorded Electric
Nau'in hawaDutsen bango
Kayan abuKarfe
LauniFari
Girman samfur4.25 x 6.25 x 4.8 inci
Nauyin Abu4.98 fam
UPC781370410117

Garanti da Taimako

For warranty information or technical support, please contact Philips Lighting customer service. Keep your purchase receipt as proof of purchase.

Mai ƙira: Philips Lighting

Website: Ziyarci Shagon PHILIPS akan Amazon