Ohaus ST10C-A

Littafin Umarnin Umarnin Mita alkalami na Ohaus ST10C-A

Model: ST10C-A

1. Gabatarwa

The Ohaus ST10C-A Pen Meter is designed for simple, fast, and accurate measurement. This economical device offers reliable performance for various applications. Its durable construction and user-friendly features make it suitable for consistent use in diverse environments.

2. Samfurin Ya Ƙareview

The ST10C-A Pen Meter is a compact, handheld device. Key features include a clear digital display, an intuitive on/off button, a protective sensor cap, and a wrist strap for secure handling.

Ohaus ST10C-A Pen Meter displaying '8.8 pH' on its screen, with red caps and a white body.

Hoto na 1: Ohaus ST10C-A Pen Meter. This image shows the Ohaus ST10C-A Pen Meter. It features a digital display for pH readings, an 'On/Off' button, and a durable, waterproof design with red accents.

The meter's IP67 waterproof ABS housing ensures protection against dust and water ingress, making it suitable for wet conditions. An automatic shutdown feature helps conserve battery life.

3. Saita

  1. Cire kaya: Carefully remove the meter and all accessories from the packaging. Inspect for any damage.
  2. Shigar da Baturi: The meter typically comes with batteries pre-installed or requires simple installation. Refer to the battery compartment cover for instructions on opening and inserting batteries, ensuring correct polarity.
  3. Sensor Preparation: Remove the protective sensor cap. If the sensor appears dry, condition it according to standard pH electrode practices (e.g., soaking in storage solution or pH 7 buffer for a short period).
  4. Daidaitawar Farko: For optimal accuracy, perform an initial calibration using fresh pH buffer solutions (e.g., pH 4.01, 7.00, and 10.01). Follow the calibration procedure outlined in the meter's specific quick start guide or on-screen prompts.

4. Umarnin Aiki

  1. Kunnawa/Kashewa: Danna maɓallin Kunna/Kashe button located on the front of the meter to turn the device on or off.
  2. Ɗaukar Ma'auni:
    • Ensure the sensor cap is removed.
    • Rinse the sensor with distilled water before and after each measurement.
    • Nutsar da firikwensin cikin sample solution, ensuring the sensor tip is fully submerged.
    • Gently stir the solution to ensure homogeneity and allow the reading to stabilize.
    • Read the pH value displayed on the screen once it becomes stable.
  3. Rufewa ta atomatik: The meter is equipped with an automatic shutdown feature to conserve battery life. It will power off after a period of inactivity.

5. Kulawa

  • Cleaning the Sensor: After each use, rinse the sensor thoroughly with distilled or deionized water. Do not wipe the sensor bulb, as this can cause static charges and damage the sensitive glass.
  • Ajiya: Always replace the protective sensor cap after use. Ensure the cap contains a small amount of storage solution (or pH 7 buffer) to keep the sensor hydrated. Never store the sensor dry or in distilled water.
  • Madadin Baturi: When the battery indicator appears on the display, replace the batteries promptly. Refer to the battery compartment for the correct battery type and installation procedure.
  • Tsabtace Gabaɗaya: The meter's housing can be cleaned with a damp zane. Ka guji yin amfani da sinadarai masu tsauri ko goge goge.

6. Shirya matsala

MatsalaDalili mai yiwuwaMagani
Mita ba ta kunna ba.Matattu ko shigar batura ba daidai ba.Sauya batura, yana tabbatar da daidaitaccen polarity.
Karatu marasa daidaito ko marasa tabbas.
  • Sensor is dirty or dry.
  • Calibration is required or incorrect.
  • Temperature difference between sample and buffer.
  • Clean and rehydrate sensor.
  • Perform a fresh calibration with new buffer solutions.
  • Izin samples and buffers to reach the same temperature.
Lokacin amsawa a hankali.Sensor is old or contaminated.Clean the sensor. If problem persists, consider replacing the sensor.

7. Ƙayyadaddun bayanai

  • Samfura: Saukewa: ST10C-A
  • Alamar: Hausa
  • Gidaje: IP67 waterproof ABS
  • Siffofin: Protective sensor cap, automatic shutdown, wrist strap
  • Girma: Approximately 15 x 10 x 4 inches (Product dimensions as listed, note this might be packaging size)
  • Nauyi: Approximately 2 Pounds (Product weight as listed, might be shipping weight)

Note: Specific measurement ranges, accuracy, and resolution details should be confirmed with the official Ohaus product data sheet.

8. Garanti da Tallafawa

For detailed warranty information, technical support, or service inquiries, please refer to the official Ohaus website or contact your local Ohaus representative. Keep your purchase receipt for warranty claims.

Official Ohaus Website: www.ohaus.com

Takardu masu alaƙa - Saukewa: ST10C-A

Preview OHAUS ST10R & ST20R Pen ORP Meter Instruction Manual
Comprehensive instruction manual for OHAUS ST10R and ST20R waterproof pen ORP meters, detailing setup, operation, maintenance, specifications, and compliance information.
Preview OHAUS ST Series Pen Meter Instruction Manual - ST10 pH Meter Guide
Comprehensive instruction manual for the OHAUS ST Series Pen Meter, model ST10. Learn about pH measurement, accuracy, maintenance, and specifications for this waterproof pen pH meter.
Preview OHAUS ST Series Manual Umarnin Mita
Instruction manual for the OHAUS ST Series Pen Meter, specifically the ST20 waterproof pen pH meter. Covers first usage, calibration, maintenance, and specifications.
Preview OHAUS a-AB33M1 Analyzer Multi-parameter & Bench Mita: Shigarwa & Jagorar Aiki
Cikakken jagorar koyarwa na OHAUS a-AB33M1 Mai Analyzer Multi-parameter Analyzer, a-AB33PH pH Meter, a-AB41PH pH Mita, da a-AB33EC Mitar Ayyuka. Yana rufe shigarwa, aiki, kulawa, aminci, da ƙayyadaddun fasaha don amfani da dakin gwaje-gwaje.
Preview OHAUS AquaSearcher AP50MM Jagorar Jagorar Hoto Mai ɗaukar hoto
Cikakken jagorar koyarwa don OHAUS AquaSearcher AP50MM Mai ɗaukar hoto mai ɗaukar hoto, dalla-dalla shigarwa, aiki, da kiyayewa don ma'aunin launi da turbidity a fagen da aikace-aikacen dakin gwaje-gwaje.
Preview OHAUS ST400 & ST400M Portable pH and Multi-Parameter Meter Instruction Manual
This instruction manual provides detailed guidance for operating and maintaining the OHAUS ST400 portable pH meter and ST400M portable multi-parameter meter. Learn about installation, setup, measurement procedures, calibration, maintenance, and technical specifications for accurate and reliable results.