1. Gabatarwa
This manual provides essential information for the proper installation, operation, and maintenance of your RISCO RK150DTG300B Dual Technology Ceiling Detector. This advanced security device offers 360° coverage, combining passive infrared (PIR) and microwave (MW) technologies for reliable motion detection in various environments.
For optimal performance and safety, please read this manual thoroughly before installation and use. Keep it for future reference.
2. Bayanin Tsaro
WARNING: Risk of electric shock. Installation should only be performed by qualified personnel.
- Disconnect power before performing any installation or maintenance.
- Ensure all wiring complies with local electrical codes and regulations.
- Kada a bijirar da na'urar ga danshi, matsanancin zafi, ko hasken rana kai tsaye.
- An tsara wannan na'urar don amfanin cikin gida kawai.
- Tampering with the device may void the warranty and compromise security.
3. Abubuwan Kunshin
Tabbatar cewa duk abubuwa suna nan a cikin kunshin:
- RISCO RK150DTG300B Dual Technology Ceiling Detector Unit
- Hardware mai hawa (skru, anchors)
- Jagorar mai amfani (wannan takaddar)

Hoto 1: Gaba view of the RISCO RK150DTG300B Dual Technology Ceiling Detector.
4. Saita da Shigarwa
The RK150DTG300B is designed for ceiling mounting to provide optimal 360° detection coverage.
4.1. Zaɓin Yanar Gizo
- Choose a central location on the ceiling within the area to be protected.
- Avoid mounting near heat sources, air conditioning vents, or areas with significant air drafts that could cause false alarms.
- Ensure the detection area is clear of large obstructions.
4.2. Mounting the Detector
- Carefully separate the detector's base from its cover.
- Position the base on the chosen ceiling location and mark the drilling points.
- Haɗa ramuka kuma saka anka masu dacewa idan ya cancanta.
- Secure the detector base to the ceiling using the provided screws.

Hoto na 2: Example of detector mounting points and internal components.
4.3. Wayoyi
The RK150DTG300B is powered by an electrical cable. Connect the detector to your security system's control panel according to the panel's instructions and the detector's terminal markings.
- Haɗin Wuta: Connect the power supply wires to the designated terminals.
- Alamar Aararrawa: Connect the alarm output to the appropriate zone input on your control panel.
- Tampko Fitowa: Haɗa tamper output to a 24-hour tamper zone on your control panel. The detector features anti-removal and anti-opening tampkare kariya.
- EOL Resistors: Integrated End-Of-Line (EOL) resistors are selectable via jumpers. Refer to your control panel's manual for the required EOL resistor values and configure the detector accordingly.
4.4. Configuration and Testing
- Anti-Cloak Technology (ACT): This feature enhances detection capabilities by identifying attempts to mask the infrared signal.
- Green Line Feature: Allows for the deactivation of the microwave (MW) channel when the security system is disarmed, reducing power consumption and potential interference. This is typically configured during installation.
- Gwajin Tafiya: After installation, perform a walk test to verify the detector's coverage and sensitivity. Walk through the entire protected area to ensure the detector triggers an alarm. Adjust sensitivity if necessary (refer to specific jumper settings or potentiometers if available on the device, though not explicitly detailed in product description).
5. Yin aiki da Mai ganowa
The RISCO RK150DTG300B operates automatically once properly installed and powered. It continuously monitors the protected area using its dual technology sensors.
- Fasaha Biyu: The detector combines Passive Infrared (PIR) and Microwave (MW) detection. Both technologies must typically be triggered simultaneously to generate an alarm, significantly reducing false alarms.
- 360° Rufewa: The ceiling mount design provides a full 360-degree detection pattern, covering an area up to 13 meters in diameter.
- TampKariya: The integrated anti-removal and anti-opening tamper switches will trigger an alarm if the detector is tampered with or forcibly removed from its mounting location.
6. Kulawa
To ensure the long-term reliability and performance of your detector, follow these maintenance guidelines:
- Tsaftacewa: Periodically clean the detector's lens and housing with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Gwaji na yau da kullun: Perform a walk test at least once a year, or as recommended by your security system provider, to confirm proper operation.
- Dubawa: Visually inspect the detector for any signs of damage or loose connections.
7. Shirya matsala
If you experience issues with your RK150DTG300B detector, refer to the following common problems and solutions:
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| Ƙararrawar Ƙarya | Heat sources, air drafts, small animals, improper sensitivity settings. | Relocate detector, eliminate drafts, adjust sensitivity (if applicable), ensure proper mounting. |
| Babu Ganewa | Power loss, incorrect wiring, obstructed view, detector malfunction. | Check power supply, verify wiring, clear obstructions, perform walk test. If problem persists, contact support. |
| Tampda Ƙararrawa | Detector cover open, unit removed from mounting, loose connections. | Ensure cover is securely closed, unit is firmly mounted, check tampina waya. |
If troubleshooting steps do not resolve the issue, contact your security system installer or RISCO technical support.
8. Ƙayyadaddun bayanai
| Mai ƙira | RISCO |
| Samfura | RK150DTG300B |
| Launi | Grey |
| Nau'in Wuta | Kebul na lantarki |
| Nau'in hawa | Rufin Dutsen |
| Matsakaicin Rage | 13 Meters (360° coverage) |
| Na'urori masu jituwa | Tsarin Tsaro |
| An Shawarar Amfani | Home and Business Security and Automation |
| Fasahar Ganewa | Dual Technology (Passive Infrared & Microwave) |
| Siffofin Musamman | Anti-Cloak Technology (ACT), Green Line (MW deactivation), Integrated EOL resistors, Anti-removal and anti-opening tamper. |
| UPC | 712073721507 |
9. Garanti da Tallafawa
For warranty information, please refer to the terms and conditions provided by your point of purchase or contact RISCO Group directly. RISCO Group products are typically covered by a limited warranty against defects in materials and workmanship.
For technical support, installation assistance, or further inquiries, please contact your authorized RISCO installer or visit the official RISCO Group website don albarkatun tallafi.
Mai ƙira: Ƙungiyar RISCO
Website: www.riscogroup.com