Apogee MQ-210

Apogee MQ-210 Underwater Quantum Light PAR Meter User Manual

Model: MQ-210

1. Gabatarwa

The Apogee MQ-210 Quantum Light PAR Meter is designed for precise measurement of Photosynthetic Active Radiation (PAR) in underwater environments. This device features a waterproof quantum sensor connected to a handheld meter. The MQ-210 is specifically engineered to apply an immersion effect correction factor directly through its firmware, ensuring accurate readings in aquatic settings. It is suitable for various light sources, though specific post-measurement correction factors may be required for LED light sources to achieve optimal accuracy.

Important Note: While the sensor and its cable are fully waterproof, the handheld meter unit is NOT waterproof and must be kept dry.

2. Bayanin Tsaro

  • Always ensure the handheld meter remains dry. Exposure to water will damage the unit and void the warranty.
  • Do not attempt to open or modify the handheld meter or the sensor. This can lead to damage and inaccurate readings.
  • Handle the sensor cable with care to prevent kinks or damage, which could compromise its waterproof integrity.
  • Keep the device away from extreme temperatures and direct sunlight when not in use.
  • Use only specified batteries (if applicable, refer to product packaging or Apogee documentation).

3. Abubuwan Kunshin

Bayan cire kayan, da fatan za a tabbatar da cewa duk abubuwan da aka gyara suna nan:

  • Apogee MQ-210 Handheld Meter
  • Waterproof Quantum Sensor (attached via cable)
  • Jagorar mai amfani (wannan takaddar)

4. Samfurin Ya Ƙareview

The MQ-210 system comprises two main parts: the handheld display unit and the waterproof quantum sensor.

Apogee MQ-210 Underwater Quantum Light PAR Meter with handheld unit and sensor

Hoto na 1: Apogee MQ-210 Underwater Quantum Light PAR Meter. This image displays the complete MQ-210 unit, featuring the handheld meter with its digital display and control buttons, connected by a cable to the compact, black waterproof quantum sensor. The sensor is designed for submersion, while the handheld unit is for dry use.

4.1 Handheld Meter

The handheld meter features a digital display for showing PAR readings in µmol m⁻² s⁻¹. It includes control buttons for power, sampling, and mode selection. The meter processes the raw sensor data and applies the immersion effect correction factor.

4.2 Waterproof Quantum Sensor

Close-up of Apogee waterproof quantum sensor

Hoto na 2: Kusa view of the Apogee waterproof quantum sensor. This image highlights the robust, anodized aluminum body and the acrylic diffuser of the sensor head. The sensor contains a blue-enhanced silicon photodiode and custom optical filters, designed for accurate underwater PAR measurements.

The sensor incorporates a blue-enhanced silicon photodiode and custom optical filters housed within a rugged, anodized aluminum body with an acrylic diffuser. It is designed for full submersion in water, making it ideal for applications such as saltwater aquariums.

5. Saita

  1. Cire na'urar: Carefully remove the handheld meter and sensor from its packaging.
  2. Duba Lalacewar: Check the handheld meter, sensor, and cable for any visible signs of damage. If damage is found, do not proceed with setup and contact support.
  3. Shigar da Baturi (idan ya dace): If the meter requires user-installed batteries (not specified, but common for handheld devices), open the battery compartment (usually on the back) and insert the correct type and number of batteries, observing polarity.
  4. Haɗin Sensor: The quantum sensor is permanently attached to the handheld meter via a waterproof cable. Ensure the cable connection point to the sensor is secure and undamaged.
  5. Ƙarfin Farko A Kunna: Press the power button on the handheld meter to turn it on. The display should illuminate and show a reading.

6. Umarnin Aiki

6.1 Kunnawa / Kashewa

  • To power on the meter, press the Ƙarfi button (usually marked with a circle and vertical line symbol).
  • Don kashe wuta, latsa ka riƙe Ƙarfi button har sai nuni ya kashe.

6.2 Daukar Ma'auni

  1. Sanya Sensor: Carefully submerge the waterproof quantum sensor into the water at the desired depth and location for measurement. Ensure the sensor's acrylic diffuser is clean and unobstructed.
  2. Observe Readings: The handheld meter's display will show the real-time PAR reading in µmol m⁻² s⁻¹. The MQ-210 automatically applies the immersion effect correction factor in its firmware for underwater measurements.
  3. Sampling (if applicable): If the meter has a "sample" button, pressing it may log the current reading or provide a stable reading. Refer to the on-screen indicators for specific sampling ayyuka.
  4. Mode Selection (if applicable): Use the "mode" button to cycle through different display modes or settings if available.

6.3 LED Light Source Considerations

While the MQ-210 is excellent for most light sources, when measuring PAR from LED light sources, post-measurement correction factors may need to be applied for the most accurate results. Consult Apogee Instruments' official documentation or website for specific correction factors pertaining to various LED types.

7. Kulawa

7.1 Tsaftacewa

  • Sensor: After each use in water, rinse the sensor with fresh water to remove any salt, debris, or biological film. Gently wipe the acrylic diffuser with a soft, non-abrasive cloth. Avoid using harsh chemicals or abrasive materials that could scratch the diffuser.
  • Handheld Meter: Clean the handheld meter with a dry, soft cloth. Do not use liquid cleaners or immerse the meter in water.

7.2 Adana

  • Store the MQ-210 in a cool, dry place away from direct sunlight and extreme temperatures.
  • If storing for extended periods, remove batteries from the handheld meter to prevent leakage (if applicable).
  • Keep the sensor and cable free from kinks or sharp bends during storage.

8. Shirya matsala

MatsalaDalili mai yiwuwaMagani
Mita baya kunnawa.Matattu ko shigar batura ba daidai ba.Maye gurbin batura da sababbi, yana tabbatar da daidaitaccen polarity.
Inaccurate or erratic readings.
  • Dirty sensor diffuser.
  • Na'urar firikwensin ko kebul da ta lalace.
  • Incorrect application of LED correction factor (for LED sources).
  • Clean the sensor diffuser gently.
  • Inspect sensor and cable for damage. If damaged, contact support.
  • Refer to Apogee documentation for LED correction factors.
Display shows "Error" or unusual characters.Matsalar ciki ko matsalar firikwensin.Try powering off and on again. If the error persists, contact Apogee Instruments support.
Buttons ba su da amsa.Internal button malfunction or software issue.Power cycle the device. If buttons remain unresponsive, contact Apogee Instruments support.

9. Ƙayyadaddun bayanai

SiffarDaki-daki
SamfuraMQ-210
Nau'in Ma'auniUnderwater Photosynthetic Active Radiation (PAR)
Nau'in SensorBlue-enhanced silicon photodiode with custom optical filters
Sensor Jikin MaterialRugged, anodized aluminum with acrylic diffuser
Immersion Effect CorrectionAutomatically applied via firmware
Handheld Meter Water ResistanceBa mai hana ruwa ba
Sensor Water ResistanceCikakken mai hana ruwa
Mai ƙiraApogee Instruments

10. Garanti da Tallafawa

For detailed warranty information, technical support, or service inquiries, please contact Apogee Instruments directly. Refer to their official webshafin yanar gizo don cikakkun bayanai na yanzu game da hulɗa da manufofin garanti.

It is recommended to register your product with Apogee Instruments to ensure you receive updates and support.

Takardu masu alaƙa - MQ-210

Preview Apogee Duet 2 User Guide: Setup, Operation, and Applications
This user guide provides comprehensive instructions for the Apogee Duet 2 audio interface, covering setup, connection, operation, integration with DAWs like Logic Pro and GarageBand, and troubleshooting for Mac users.
Preview Apogee Symphony I/O Troubleshooting: No Power On Issues
A technical bulletin from Apogee Electronics providing troubleshooting steps for resolving 'no power on' issues with the Symphony I/O audio interface. Covers common symptoms and guides users through checking firmware, cables, power supply, and circuit boards.
Preview Apogee Duet 3 User's Guide
Comprehensive user guide for the Apogee Duet 3 audio interface, covering setup, software installation, connectivity, configuration with DAWs, advanced features, and troubleshooting.
Preview Apogee Clearmountain's Dance User's Guide: Delay Plugin Features and Setup
Comprehensive user guide for Apogee's Clearmountain's Dance delay plugin. Learn about its analog tape emulation, ping pong delay, installation, signal routing, and troubleshooting.
Preview Jagorar mai amfani na Apogee Symphony Studio: Maɗaukakin Maɗaukaki Mai Sauti
Cikakken jagorar mai amfani ga Apogee Symphony Studio Series audio interface, rufe saitin, aiki, sarrafa software, saka idanu ayyukan aiki, da ƙayyadaddun fasaha don samar da sauti na ƙwararru.
Preview Tsarin Subwoofer na Apogee AFI-118: Babban Ayyuka 18-inch Subwoofer Audio Subwoofer
Cikakkun bayanai da fasalulluka na Apogee AFI-118 Subwoofer System, 18-inch (460mm) babban subwoofer mai ƙarfi wanda aka ƙera don aikace-aikacen sauti na ƙwararru, gami da sauti mai rai, kulake, da gidajen wasan kwaikwayo. Koyi game da direbanta, bayanan injiniyanci, da kuma dacewa.