1. Gabatarwa
This instruction manual provides essential information for the installation, operation, and maintenance of your ALDES EasyHome Auto Single Flow Self-Regulating Mechanical Ventilation System (VMC) kit. Please read this manual thoroughly before proceeding with installation or use to ensure proper functioning and safety.
2. Umarnin Tsaro
- Installation must be performed by a qualified professional in accordance with local electrical and building regulations.
- Always disconnect the power supply before performing any installation, maintenance, or repair work.
- Do not obstruct the air inlets or outlets of the VMC system.
- Ensure proper ventilation in the installation area during operation.
- Ajiye kayan tattarawa daga inda yara za su iya isa.
3. Abubuwan Kunshin
Tabbatar cewa duk abubuwan da aka lissafa a ƙasa suna cikin kayan aikin ku:
- 1 x ALDES EasyHome Auto VMC Unit
- Duct connection adapters
- Self-regulating extraction grilles (for humid rooms like bathrooms, kitchens, WCs)
- Mounting accessories (screws, plugs)
- Jagoran Jagora

Hoto na 1: Ƙarsheview of the ALDES EasyHome Auto VMC kit, showing the main ventilation unit with its multiple duct connections and three self-regulating extraction grilles.
4. Saita da Shigarwa
Bi waɗannan matakan don shigarwa da kyau:
- Wurin Wuri: Install the VMC unit in a dry, accessible location, typically in an attic, false ceiling, or utility room. Ensure sufficient space for maintenance and air circulation around the unit.
- hawa: Securely mount the VMC unit using the provided mounting accessories. Ensure it is level and stable to minimize vibration and noise.
- Haɗin Wuta: Connect the appropriate ducts to the VMC unit's inlets (from humid rooms) and outlet (to outside). Use flexible or rigid ducts of the correct diameter. Ensure all connections are airtight using clamps da sealant.
- Shigar da Grille: Install the self-regulating extraction grilles in the designated humid rooms (kitchen, bathroom, WC). Ensure they are securely fixed and not obstructed.
- Haɗin Wutar Lantarki: Connect the VMC unit to the main electrical supply via a dedicated circuit breaker, following the wiring diagram provided in the unit's specific installation guide (not included in this general manual). This step must be performed by a qualified electrician.
- Duba tsarin: Once installed, power on the unit and verify that air is being extracted from the humid rooms and expelled outside.
5. Umarnin Aiki
The ALDES EasyHome Auto VMC system is designed for continuous operation and self-regulation. It automatically adjusts the airflow based on the humidity levels in your home, ensuring optimal air quality without manual intervention.
- Ci gaba da Aiki: The system should operate 24/7 to effectively renew indoor air.
- Automatic Regulation: The self-regulating grilles and VMC unit automatically adapt the airflow to the needs of each room, extracting more air when humidity is high (e.g., during showering or cooking).
- Boost Function (if applicable): Some models may include a boost function for temporary increased ventilation. Refer to your specific unit's documentation if this feature is present.
6. Kulawa
Regular maintenance ensures the longevity and efficiency of your VMC system:
- Tsabtace Grille: Periodically clean the extraction grilles (every 3-6 months) to remove dust and debris. They can typically be unclipped and washed with warm soapy water. Ensure they are completely dry before reattaching.
- VMC Unit Cleaning: Annually, inspect the VMC unit for dust accumulation. If accessible, gently clean the fan blades and interior with a soft brush or vacuum cleaner. Always disconnect power before cleaning the unit.
- Duct Inspection: Every 3-5 years, inspect the ducts for blockages or damage. Professional cleaning may be required for heavily soiled ducts.
7. Shirya matsala
If you encounter issues with your VMC system, refer to the following common problems and solutions:
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| Babu iska ko raunin iska | Power supply disconnected, blocked grilles/ducts, fan malfunction. | Check power supply. Clean grilles. Inspect ducts for blockages. If fan malfunction, contact support. |
| Yawan surutu | Loose mounting, obstructed fan, dirty fan blades, duct vibration. | Ensure unit is securely mounted. Clean fan. Check duct connections for tightness. |
| Condensation in rooms | Insufficient airflow, blocked grilles, system off. | Ensure system is running continuously. Clean grilles. Check for duct blockages. |
If the problem persists after attempting these solutions, please contact ALDES customer support.
8. Ƙayyadaddun bayanai
| Siffar | Daki-daki |
|---|---|
| Alamar | ALDES |
| Maganar Samfura | 11026032 |
| Kayan abu | Filastik |
| Nauyi | 5 kilogiram |
| ASIN | B077MH6CPX |
| Ƙasar Asalin | Faransa |
9. Garanti da Tallafawa
For warranty information, technical support, or spare parts, please refer to the official ALDES website or contact your local ALDES distributor. Keep your proof of purchase for warranty claims.
ALDES Contact Information: Da fatan za a ziyarci www.aldes.com don samun cikakkun bayanai game da hulɗa da albarkatun tallafi na zamani.