1. Gabatarwa
This manual provides essential information for the safe and efficient operation of your Voltcraft VLP-1602 USB Laboratory Power Supply. The VLP-1602 is a versatile, adjustable power supply designed for laboratory and development applications, offering precise control over voltage da halin yanzu.
Babban fasali sun haɗa da:
- Electronic linear regulation for stable output without ripple.
- Three independent outputs.
- Ƙarfafawatage Kariya (OVP).
- Integrated USB test and development socket for stressing connected USB devices.
- Daidaitacce voltage from 0 to 60 V and current from 0.01 to 1.5 A.
2. Bayanin Tsaro
Da fatan za a karanta kuma a fahimci duk umarnin aminci kafin a yi amfani da na'urar. Rashin bin waɗannan umarnin na iya haifar da girgizar lantarki, gobara, ko mummunan rauni.
- Tsaron Wutar Lantarki: Always connect the power supply to a grounded outlet. Do not operate the device with damaged power cords or if the casing is open.
- Samun iska: Tabbatar da isasshen iska a kusa da naúrar. Kar a toshe buɗewar samun iska.
- Muhalli: Use the device in a dry environment, away from moisture, dust, and direct sunlight.
- Kariya fiye da kima: Kada ku wuce ƙayyadadden ƙarartage and current ratings. The device includes Overvoltage Kariya (OVP).
- Hidima: Refer all servicing to qualified personnel. Do not attempt to repair the unit yourself.
- Yara: A kiyaye na'urar daga wurin yara.
3. Saita
3.1 Cire kaya da dubawa
Carefully remove the power supply from its packaging. Inspect the unit for any signs of damage that may have occurred during transit. If any damage is found, do not operate the device and contact your supplier.
3.2 Haɗa zuwa Ƙarfi
- Ensure the power switch on the front panel is in the "OFF" position.
- Connect the provided power cord to the AC inlet on the rear panel of the power supply.
- Plug the other end of the power cord into a standard 230V AC, 50Hz grounded electrical outlet.

3.3 Ƙarfin Farko Kunna
After connecting the power cord, switch the power supply ON using the main power switch on the front panel. The display should illuminate, indicating the device is ready for operation.
4. Umarnin Aiki
4.1 Gabatarwar Gabaview

The front panel features digital displays for voltage and current, control knobs for precise adjustment, and multiple output terminals.
4.2 Adjusting Voltage and Current (Output A)
- Connect your load to the main output terminals (Output A). Use the red terminal for positive (+) and the black terminal for negative (-). The yellow terminal is for ground.
- Turn the "VOLT" knob to set the desired output voltage. The digital display will show the set voltage.
- Turn the "AMPERE" knob to set the desired current limit. This acts as a current limiter to protect your circuit.
- The "C-LIMIT" indicator will illuminate if the current limit is reached.
- The "OVP" (Overvoltage Protection) indicator will illuminate if an overvoltage condition occurs.

4.3 Using the USB Outputs (Output B-USB)
The VLP-1602 includes dedicated USB outputs for testing and development purposes. These outputs can be used to stress connected USB devices.
- Connect your USB device to one of the USB-B1 or USB-B2 ports.
- Use the "MODE" switch to select the desired USB output mode (e.g., 4.8-5.2V, 4.5-4.7V, Normal).
- The "ADJ" knob allows for fine adjustment of the USB output voltage within the selected mode.
- Refer to the labels near the USB ports for specific voltage and current ratings (e.g., USB-B1: 5V/2A, USB-B2: 12V/0.5A).
5. Kulawa
5.1 Tsaftacewa
To clean the exterior of the power supply, use a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the device is powered off and unplugged before cleaning.
5.2 Sauya Fuse
If the power supply does not turn on, check the fuse located on the rear panel near the AC inlet.
- Cire haɗin wutar lantarki daga tashar AC.
- Use a flat-head screwdriver to open the fuse holder.
- Replace the blown fuse with a new fuse of the same type and rating (T 1.6A / 250V).
- Close the fuse holder securely.
Gargadi: Always replace fuses with the specified type and rating to prevent damage to the unit or risk of fire.
6. Shirya matsala
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| Na'urar baya kunnawa. | No power from outlet, power cord disconnected, blown fuse. | Check power outlet, ensure power cord is securely connected, replace fuse (see Section 5.2). |
| Babu fitarwa voltage/yanzu. | Output terminals not connected, voltage/current knobs set to zero, OVP/OCP triggered. | Ensure load is properly connected, adjust voltage/current knobs, check for OVP/OCP indicators and reset if necessary. |
| Fitarwa voltage/current is unstable. | Poor connection, faulty load, internal issue. | Check all connections, test with a different load. If problem persists, contact support. |
| Ƙarfafawatage Protection (OVP) indicator is on. | Fitarwa voltage exceeded a safe limit. | Reduce the set voltage or check the load for issues. Power cycle the unit to reset OVP. |
7. Ƙayyadaddun bayanai
| Siga | Daraja |
|---|---|
| Lambar Samfura | Saukewa: VLP-1602 |
| Mai ƙira | GASKIYA |
| Fitarwa Voltage (Main) | 0-60 V |
| Output Current (Main) | 0.01 - 1.5 A |
| Adadin abubuwan da aka fitar | 3 (Main + 2 USB) |
| Ƙarfin fitarwa | 123 W |
| Shigar da Voltage | 230 Volts |
| Girma (L x W x H) | 27 x 26 x 11.5 cm |
| Nauyi | 6.6 kilogiram |
| Siffofin Musamman | High-precision multi-speed potentiometer, USB development port |
| Nau'in Haɗawa | USB |
8. Garanti da Tallafawa
8.1 Bayanin Garanti
The Voltcraft VLP-1602 USB Laboratory Power Supply comes with a 1-year availability of spare parts. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact your retailer.
8.2 Tallafin Abokin Ciniki
For technical assistance, troubleshooting, or service inquiries, please contact Voltcraft customer support or your authorized dealer. Please have your model number (VLP-1602) and purchase information ready when contacting support.