1. Gabatarwa
This manual provides essential information for the safe and correct installation, operation, and maintenance of the Truma Ignition Safety Valve Set, designed for use with Truma S 3002 and S 5002 heaters. Please read these instructions thoroughly before installation and use to ensure proper function and safety.
2. Bayanin Tsaro
GARGADI: Shigarwa mara kyau, daidaitawa, canji, sabis, ko kulawa na iya haifar da lalacewar dukiya, rauni, ko mutuwa. Karanta shigarwa, aiki, da umarnin kulawa sosai kafin shigarwa ko yi wa wannan kayan aiki.
- Dole ne ƙwararren mai sakawa, hukumar sabis, ko mai samar da iskar gas ya yi shigarwa da sabis.
- Always shut off the gas supply before performing any maintenance or service.
- Ensure adequate ventilation when operating gas appliances.
- Check for gas leaks after installation or service using an approved leak detection solution.
- Kada a yi amfani da harshen wuta a buɗe don duba ɓullar iskar gas.
3. Abubuwan Kunshin
Tabbatar cewa dukkan sassan suna nan kuma ba su lalace ba kafin a ci gaba da shigarwa.
- Ignition protection valve
- O-ring
- Kwaya
- Yankan zobe
- Associated wiring and mounting brackets (as pictured)

Hoto na 1: Components of the Truma Ignition Safety Valve Set. This image displays the main valve assembly with attached wiring, a flexible hose, an O-ring, a nut, a cutting ring, and two metal mounting brackets.
4. Saita da Shigarwa
This ignition safety valve set is designed for specific Truma S 3002 and S 5002 heaters. Refer to your heater's primary manual for detailed instructions on accessing the valve area.
- Shiri: Ensure the gas supply to the heater is completely shut off and the system has cooled down. Disconnect any electrical power to the heater.
- Cire Old Valve (idan an zartar): Carefully disconnect the gas lines and electrical connections from the existing safety valve. Note the orientation and connections for proper reassembly.
- Sanya Sabon Valve:
- Attach the new ignition safety valve to the heater using the provided mounting brackets. Ensure it is securely fastened.
- Connect the gas inlet and outlet lines. Use the new O-ring, nut, and cutting ring for a secure, leak-free connection. Tighten connections to manufacturer specifications, but do not overtighten.
- Connect the electrical wiring from the valve to the heater's control system. Ensure correct polarity and secure connections.
- Gwajin Leak: After installation, slowly turn on the gas supply. Apply an approved gas leak detection solution to all gas connections. Bubbles indicate a leak. If a leak is detected, immediately shut off the gas supply and re-tighten the connection. Repeat the leak test until no bubbles appear.
- Electrical Test: Restore electrical power to the heater and perform a functional test according to the heater's operating instructions.
Lura: If you are unsure about any step of the installation process, consult a qualified gas appliance technician.
5. Aiki
The Truma Ignition Safety Valve is an integral component of your Truma S 3002/5002 heater's safety system. It operates automatically to ensure safe gas flow.
- When the heater is switched on and an ignition signal is present, the safety valve opens to allow gas to flow to the burner.
- If the flame extinguishes unexpectedly (e.g., due to wind or gas supply interruption), the safety valve will automatically close the gas supply within a specified timeframe, preventing unburnt gas from accumulating.
- This valve does not require manual operation during normal use. Its function is entirely automatic and safety-critical.
6. Kulawa
Regular maintenance of your Truma heater system, including the ignition safety valve, is crucial for safe and efficient operation. While the safety valve itself requires minimal direct user maintenance, periodic checks are recommended.
- Binciken Shekara-shekara: It is recommended to have your entire Truma heating system, including the gas lines and safety valve, inspected annually by a qualified technician.
- Duban gani: Periodically inspect the valve and its connections for any signs of corrosion, damage, or loose fittings.
- Tsaftacewa: Keep the area around the valve clean and free from dust or debris. Do not use harsh chemicals or abrasive cleaners.
- Maye gurbin sashi: If any part of the safety valve set appears damaged or worn, it must be replaced with genuine Truma spare parts by a qualified technician.
7. Shirya matsala
If your Truma heater is not functioning correctly, and you suspect an issue with the ignition safety valve, consider the following:
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| Heater does not ignite or repeatedly fails to ignite. | No gas supply, faulty ignition, or safety valve not opening. |
|
| Heater ignites but flame extinguishes quickly. | Insufficient gas pressure, faulty thermocouple/flame sensor, or safety valve closing prematurely. |
|
| Kamshin gas. | Iskar gas. |
|
Muhimmi: Do not attempt repairs on gas components unless you are a qualified and certified technician. Always prioritize safety.
8. Ƙayyadaddun bayanai
- Nau'in Samfur: Ignition Safety Valve Set
- Alamar: Truma
- Dacewar Samfura: Truma S 3002, Truma S 5002 heaters
- Lambar Sashe: Saukewa: FRA309492
- Abu: Plastic (valve body may contain metal components)
- Girma (L x W x H): Kusan 2.76 x 6.3 x 2.76 inci (7 x 16 x 7 cm)
- Nauyin Abu: Kimanin oz 14.8 (420 g)
- Ƙarshen Waje: Fentin
- Girman Haɗin Inlet: 1.6E+2 Millimeters (160mm)
- Nau'in Haɗin Shiga: Cutting Ring
- Girman Haɗin Fitar: 16 millimeters
- Nau'in Haɗin Wuta: Cutting Ring
- Adadin Tashoshi: 2
- Haɗuwa Takaice: CE
9. Garanti Bayani
Specific warranty terms for the Truma Ignition Safety Valve Set are provided by the manufacturer, Truma. Please refer to the warranty documentation included with your original purchase or visit the official Truma webshafin yanar gizo don cikakkun bayanai game da garantin garanti, tsawon lokaci, da kuma hanyoyin da'awa.
Ajiye takardar shaidar siyan ku don dalilai na garanti.
10. Tallafin Abokin Ciniki
For technical assistance, spare parts, or service inquiries, please contact Truma customer support or an authorized Truma service center.
You can find contact information and a list of authorized service partners on the official Truma website: www.truma.com
When contacting support, please have your product model number (FRA309492) and purchase details ready.