1. Gabatarwa
This manual provides essential information for the safe and efficient operation, setup, maintenance, and troubleshooting of the Keba KeTop T50-xxx/67641/06 industrial control panel. The KeTop T50-xxx/67641/06 is designed for robust performance in industrial environments, serving as a human-machine interface (HMI) for various control applications.
Please read this manual thoroughly before operating the device to ensure proper usage and to prevent damage or injury.
2. Bayanin Tsaro
Koyaushe kiyaye matakan tsaro masu zuwa don hana rauni ko lalacewa ga kayan aiki:
- Ma'aikata Masu cancanta: Installation, operation, and maintenance should only be performed by qualified and authorized personnel.
- Kashe Haɗin Wuta: Always disconnect power before performing any installation, maintenance, or repair work.
- Yanayin Muhalli: Operate the device within specified environmental limits (temperature, humidity, etc.).
- Tsaida Gaggawa: Familiarize yourself with the location and operation of the emergency stop button on the device and the connected system.
- Na'urar USB: Ensure all cables are properly routed and secured to prevent tripping hazards or damage.
3. Samfurin Ya Ƙareview
The Keba KeTop T50-xxx/67641/06 is a robust handheld control panel designed for industrial applications. It features a display screen, various control buttons, and an emergency stop button, all integrated into an ergonomic housing.

Hoto 1: Gaba view of the KeTop T50-xxx/67641/06 control panel, showing the display, control buttons, and the attached red connection cable.

Figure 2: Rear label of the KeTop T50-xxx/67641/06, indicating model details and power requirements.
4. Saita da Shigarwa
Before connecting the KeTop T50-xxx/67641/06, ensure the host system is powered off and secured.
- Duba Na'urar: Unpack the control panel and inspect it for any visible damage during transit.
- Haɗa Kebul: Connect the red multi-pin cable from the KeTop T50-xxx/67641/06 to the corresponding port on your industrial control system. Ensure the connection is secure and properly seated.
- Tushen wutan lantarki: Verify that the power supply for the control system meets the specifications required by the KeTop T50-xxx/67641/06 (24 VDC/0.25 A).
- Hawa (Na zaɓi): If applicable, use the integrated mounting points to secure the panel in a convenient location, or ensure it is placed on a stable surface when not handheld.
- Ƙarfin Farko: Once all connections are secure, power on the host system. The KeTop T50-xxx/67641/06 display should illuminate, indicating successful power-up.
5. Umarnin Aiki
The KeTop T50-xxx/67641/06 serves as an interface for controlling industrial machinery. Specific operations will depend on the programming of the connected system.
- Nuna Kewayawa: Use the directional buttons (if present) or touch screen (if applicable) to navigate through menus and display information.
- Maɓallan Ayyuka: The various buttons around the display are typically assigned specific functions by the system integrator. Refer to your system's documentation for button assignments.
- Tsaida Gaggawa: In case of an emergency, press the large red emergency stop button immediately. This will typically halt all connected machine operations. Ensure the button is reset before resuming operations.
- Shigar da Bayanai: Use the integrated keypad or on-screen keyboard for data entry as required by the application.
- Jawabin: Pay attention to visual cues on the display and any audible signals from the device or connected system.
6. Kulawa
Regular maintenance ensures the longevity and reliable operation of your KeTop T50-xxx/67641/06.
- Tsaftacewa:
- Cire haɗin wuta kafin tsaftacewa.
- Shafa saman waje da taushi, damp zane.
- Do not use abrasive cleaners, solvents, or excessive moisture.
- Tabbatar babu ruwa da zai shiga na'urar.
- Duban Kebul: Periodically inspect the connection cable for signs of wear, cuts, or damage. Replace damaged cables immediately.
- Ayyukan Button: Regularly test all buttons, including the emergency stop, to ensure they respond correctly.
- Ajiya: When not in use, store the device in a clean, dry environment, away from extreme temperatures and direct sunlight.
7. Shirya matsala
This section provides solutions to common issues. For more complex problems, contact qualified service personnel.
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| Na'urar baya kunnawa. | No power from host system; loose cable connection; faulty power supply. | Check host system power; ensure cable is securely connected; verify power supply output. |
| Nuni babu komai ko kyalkyali. | Insufficient power; cable issue; internal fault. | Verify power supply; check cable integrity; if problem persists, contact support. |
| Buttons ba su da amsa. | Software issue on host system; physical button damage. | Restart the host system; inspect buttons for physical damage. |
| Emergency Stop button is stuck. | Button mechanism issue. | Do not force. Contact qualified service personnel immediately. |
8. Ƙayyadaddun bayanai
| Siffar | Daki-daki |
|---|---|
| Samfura | KeTop T50-xxx/67641/06 |
| Alamar | Keba |
| Shigar da Wuta | 24 VDC / 0.25 A (as per device label) |
| ASIN | B07NSF65HM |
| Maganar Mai ƙira | 2186 |
| Kwanan Watan Farko | Mayu 10, 2019 |
| Samuwar kayan gyara | Babu bayanin |
9. Garanti da Tallafawa
Information regarding specific warranty terms and conditions for the Keba KeTop T50-xxx/67641/06 is not provided in the product details. Please refer to the original purchase documentation or contact your supplier for warranty details.
For technical support or service inquiries, please contact the manufacturer, Keba, or your authorized distributor. Ensure you have the model number (KeTop T50-xxx/67641/06) and serial number (if applicable) ready when contacting support.