1. Gabatarwa

The RCYAGO Dissolved Oxygen Meter is a high-precision instrument designed for accurate measurement of dissolved oxygen (DO) and temperature in various water bodies. It utilizes a polarographic sensor with a thermistor for automatic temperature compensation, ensuring reliable readings across different conditions. This manual provides comprehensive instructions for setup, operation, and maintenance of your DO meter.

RCYAGO Dissolved Oxygen Meter with probe

Figure 1: RCYAGO Dissolved Oxygen Meter and Probe

2. Abin da ke cikin Akwatin

Da fatan za a duba abubuwan da ke cikin kunshin don tabbatar da duk abubuwa suna nan:

  • 1 x RCYAGO Dissolved Oxygen Meter (Model: DO9100)
  • 1 x Electrode Probe
  • 6 x Probe Protective Covers (Membrane Sleeves)
  • 1 x Electrode Filling Solution
  • 1 x Anaerobic Water Powder (for calibration)
  • 1 x Manhajar mai amfani

3. Saita

3.1 Shigar da Baturi

The meter requires 3 x 1.5V button batteries. These are typically pre-installed or included in the top cap of the device. Ensure they are correctly oriented before use.

3.2 Haɗin Lantarki

Connect the electrode probe to the main meter unit by screwing the metal knob securely. Ensure a firm connection to prevent inaccurate readings.

Diagram showing dimensions, LCD display, power button, lock/temperature switch key, mode/calibration key, and electrode interface.

Figure 2: Meter Components and Dimensions

3.3 Filling the Probe Protective Cover

The probe protective cover contains a permeable membrane. Before first use, or when replacing the membrane sleeve, fill it with the provided electrode filling solution. This solution is crucial for the sensor's proper function. Do not press on the membrane itself.

Close-up of the highly sensitive probe with multiple probe protective covers shown. The image highlights the detachable nature of the probe and the included covers.

Figure 3: Highly Sensitive Probe and Protective Covers

4. Aiki

4.1 Kunnawa/Kashewa da Nuni

Latsa maɓallin wuta () to turn the meter on. The digital screen will illuminate with a backlight, displaying DO readings and temperature. The backlight improves readability in low-light conditions. The device features an auto-power-off function after 8 minutes of inactivity to conserve battery life.

Close-up of the meter's HD backlight display showing readings, and an open battery compartment.

Figure 4: HD Backlight Display and Battery Compartment

4.2 Hanyoyin Aunawa

The meter can display dissolved oxygen in mg/L (parts per million, ppm) or as a saturation percentage (%). Press the MODE/CAL button to toggle between these modes.

4.3 Adadin Zazzabi

The meter features automatic temperature compensation (ATC) within the range of 0-50°C (32-122°F). This ensures that dissolved oxygen readings are accurate despite variations in water temperature, as oxygen solubility is affected by temperature.

Dissolved oxygen meter probe submerged in an aquarium, illustrating automatic temperature compensation.

Figure 5: Automatic Temperature Compensation in action

4.4 Calibration

Regular calibration is essential for accurate measurements. The meter supports two-point calibration: 100% air calibration and 0% anaerobic water calibration.

4.4.1 100% Air Calibration

  1. Ensure the probe is exposed to air.
  2. Dogon danna MODE/CAL button don 5 seconds.
  3. Release the button. The screen will flash 3 times at 100%. Calibration is complete.

4.4.2 0% Anaerobic Water Calibration

  1. Prepare anaerobic water: Pour 1 packet of anaerobic powder into the attached calibration bottle, add 30ml of purified water or tap water, and wait 5-10 minutes for the powder to fully dissolve.
  2. Submerge the electrode in the anaerobic water.
  3. Danna maɓallin MODE/CAL key to switch to mg/L mode.
  4. Wait for the value to drop to 0.
  5. Dogon danna MODE/CAL button don 5 seconds.
  6. Release the button. The screen will flash 3 times at 0%. Calibration is complete.
Diagram illustrating the steps for 0% anaerobic water calibration and 100% air calibration.

Figure 6: Calibration Procedures

4.5 Daukar Ma'auni

Once calibrated, submerge the electrode probe into the water sample you wish to measure. The meter will display the dissolved oxygen and temperature readings. Allow a few moments for the readings to stabilize.

Person holding the dissolved oxygen meter, with the probe submerged in a pond with fish, showing a real-world application.

Figure 7: Measuring Dissolved Oxygen in a Pond

4.6 Raka'o'in Zafin Canjawa

To switch between Celsius (°C) and Fahrenheit (°F), long press the RIKO/TEMP maballin.

4.7 Understanding Oxygen Solubility

Oxygen solubility in water is influenced by temperature, atmospheric pressure, and salinity. The provided table illustrates the saturation concentration of oxygen at different temperatures:

Table showing saturation concentration of oxygen in mg/L and percentage at various temperatures in Celsius and Fahrenheit.

Figure 8: Oxygen Saturation Concentration at Different Temperatures

5. Kulawa

5.1 Probe Protective Cover (Membrane Sleeve)

The film inside the protective cover cannot be taken apart. If test values become inaccurate even after calibration, the membrane sleeve needs to be replaced. The meter comes with 6 spare covers.

5.2 Tsaftacewa

The meter unit and probe should be cleaned with care. The product care instructions specify 'Hand Wash Only'. Avoid harsh chemicals or abrasive materials.

5.3 Adana

When not in use, ensure the probe protective cover is properly filled with solution and securely attached to protect the sensor. Store the meter in a cool, dry place.

6. Shirya matsala

  • Karatuttukan da ba daidai ba: Ensure the electrode is properly connected and the membrane sleeve is filled with the electrode filling fluid. Perform calibration regularly (both air and anaerobic water calibration) as described in Section 4.4.
  • Abubuwan Nuni: Check battery levels. If the display is dim or erratic, replace the batteries.
  • No Reading: Verify the electrode is fully submerged in the sample and that the connection to the meter is secure.
  • gazawar daidaitawa: Ensure the anaerobic water powder is fully dissolved for 0% calibration. For air calibration, ensure the probe is exposed to stable ambient air. If issues persist, the membrane sleeve might need replacement.

7. Ƙayyadaddun bayanai

SiffarDaki-daki
Girman samfur6.1 x 0.01 x 0.01 inci
Lambar Samfurin AbuDO9100
Nauyi12.56 oz
AlamarRCYAGO
Siffa ta MusammanBabban Daidaito
LauniBaki
Kayan WajeFilastik
Nau'in NuniHasken Baya na Dijital
Dissolved Oxygen Range0.0-40.0mg/L
Dissolved Oxygen Saturation0.0-300.0%
Yanayin Zazzabi0.0-40.0°C (32.0-104.0°F)
Matsakaicin Zazzabi ta atomatik0-50 ° C
Tushen wutar lantarki3 x 1.5V Button Batteries
Kashewa ta atomatik8 minutes

8. Bidiyon Samfura

8.1 Digital Dissolved Oxygen Meter - Basic Operation & Calibration

This video provides a quick overview of the RCYAGO Dissolved Oxygen Meter, demonstrating how to power it on, install the electrode, and perform both air and oxygen-free water calibrations. It highlights the key steps for initial setup and ensuring accurate readings.

8.2 Portable Dissolved Oxygen Meter - Detailed Review & Usage

This comprehensive video offers a detailed review of the portable dissolved oxygen meter. It covers unboxing, battery installation, electrode setup, and practical demonstrations of measuring dissolved oxygen in different water samples (tap water vs. boiled water). The video also discusses the included accessories like membrane caps and electrolyte solution, and explains the temperature conversion chart.

9. Garanti da Tallafawa

For warranty information, technical support, or to purchase replacement parts (such as probe protective covers or electrode filling solution), please contact RCYAGO customer service. Refer to the product packaging or the official RCYAGO webshafin don cikakkun bayanai.

Takardu masu alaƙa - DO9100

Preview DO-9100 Pen Type Intelligent Dissolved Oxygen Analyzer Instruction Manual
This document provides instructions for the DO-9100 pen type intelligent dissolved oxygen analyzer, covering its features, technical parameters, operation, maintenance, and troubleshooting.
Preview RCYAGO SGW07 Mai Amfani da Mai ƙidayar Ruwa Dual Water Timer
Cikakken jagorar mai amfani don RCYAGO SGW07 Dual Water Timer. Koyi game da samfurin ya ƙareview, ƙayyadaddun bayanai, shigarwa, shirye-shiryen shayarwa ta atomatik, shayarwar hannu, jinkirin ruwan sama, magance matsala, da matsayin baturi don tsarin ban ruwa na lambun ku.
Preview Портативный оксиметр Yinmik DO9100, BLE9100: Руководство пользователя
Полное руководство пользователя для портативного оксиметра Yinmik моделей DO9100 и BLE9100. Охватывает технические характеристики, калибровку, эксплуатацию, обслуживание и гарантию.