POTTER SL 5A C

POTTER 12/24 VDC 4-Wire Strobe Light User Manual

Model: SL 5A C

1. Gabatarwa

This user manual provides detailed instructions for the installation, operation, and maintenance of the POTTER 12/24 VDC 4-Wire Strobe Light, Model SL 5A C. This device is designed to provide visual signaling in various applications, particularly in fire safety and alarm systems. Please read this manual thoroughly before installation and operation to ensure proper function and safety.

2. Bayanin Tsaro

Koyaushe riko da lambobi da ƙa'idodi na gida lokacin shigarwa da aiki da wannan na'urar. Rashin yin hakan na iya haifar da hasarar dukiya, rauni, ko mutuwa.

3. Samfurin Ya Ƙareview

The POTTER SL 5A C is a robust 12/24 VDC 4-wire cylindrical strobe light designed for clear visual signaling. It features a durable metal construction with a powder-coated finish and utilizes a Light Emitting Diode (LED) as its light source. Available in clear, red, orange, and yellow lens options.

3.1. Aka gyara

3.2. Hoton Samfur

Four POTTER cylindrical strobe lights in orange, blue, clear, and red.

Image: A visual representation of four POTTER cylindrical strobe lights. From left to right, the lights are shown with orange, blue, clear, and red lenses. Each unit consists of a black base and a ribbed, translucent cylindrical lens, illustrating the design and color variations of the product line.

4. Saita da Shigarwa

Follow these steps for proper installation of the POTTER SL 5A C strobe light:

  1. Kashe Haɗin Wuta: Ensure all power to the installation area is disconnected at the circuit breaker or fuse box before beginning any wiring.
  2. Wurin Hauwa: Select a suitable mounting location that is stable, dry, and provides clear visibility for the strobe light. The device is designed for surface mounting.
  3. Hawan Tushen: Secure the mounting base to the chosen surface using appropriate fasteners (not included). Ensure the base is firmly attached.
  4. Waya: Connect the 4-wire power source to the terminals on the strobe light unit. Pay close attention to polarity (positive and negative) and ensure connections are secure. Refer to the wiring diagram provided with the product packaging for specific terminal assignments.
  5. Attach Strobe Unit: Once wiring is complete and verified, carefully attach the strobe light unit to its mounted base. Ensure it clicks or locks securely into place.
  6. Maido da Wuta: Restore power to the circuit and test the strobe light for proper operation.

5. Umarnin Aiki

The POTTER SL 5A C strobe light operates automatically when power is supplied to its 4-wire connection. It is designed to provide a continuous visual strobe signal when activated by the connected alarm or control panel.

6. Kulawa

The POTTER SL 5A C strobe light requires minimal maintenance. Regular inspection and cleaning will help ensure its longevity and reliable operation.

7. Shirya matsala

If the strobe light is not functioning as expected, refer to the following table for common issues and solutions:

MatsalaDalili mai yiwuwaMagani
Strobe light does not flash.Babu wutar lantarki.
Incorrect wiring/polarity.
Naúrar mara kyau.
Verify power is supplied to the unit.
Check all wiring connections for correctness and tightness, ensuring correct polarity.
If power and wiring are correct, the unit may be faulty and require replacement.
Strobe light flashes intermittently.Sako da wayoyi.
Rashin isasshen iko.
Bincika kuma ƙara duk hanyoyin haɗin waya.
Ensure the power supply is stable and within the 12/24 VDC range.
Fitowar haske ba ta da ƙarfi.ruwan tabarau mai datti.
Ƙara girmatage.
Tsaftace ruwan tabarau da taushi, damp zane.
Tabbatar da shigarwar voltage is within the specified range (12/24 VDC).

8. Ƙayyadaddun bayanai

SiffarDaki-daki
Lambar SamfuraSL 5A C
Lambar SashePSL5AC
UPC742779300874
Voltage12/24 VDC
Waya4-Haɗin Waya
Nau'in Tushen HaskeHaske Emitting Diode (LED)
Zaɓuɓɓukan launiClear, Red, Orange, Yellow (lens)
SiffarSilindrical
Kayan abuKarfe
Nau'in ƘarsheFoda Mai Rufe
Nau'in hawaDutsen Surface
Mai ƙiraPOTTER

9. Garanti da Tallafawa

For information regarding the product warranty, please refer to the warranty card included with your purchase or visit the official POTTER website. For technical support, troubleshooting assistance beyond this manual, or replacement parts, please contact POTTER customer service through their official channels.

Note: Unauthorized modifications or repairs may void the product warranty.

Takardu masu alaƙa - SL 5A C

Preview Potter PS120 Series Supervisory Pressure Switch Installation and Specifications
Detailed installation guide, technical specifications, and wiring instructions for the Potter PS120 Series Supervisory Pressure Switch used in fire sprinkler systems.
Preview Potter PS120 (VdS) Supervisory Pressure Switch - Technical Specifications and Installation Guide
Detailed technical specifications, installation instructions, and wiring diagrams for the Potter PS120 (VdS) Supervisory Pressure Switch, designed for automatic fire sprinkler systems. Includes features, certifications, and ordering information.
Preview Potter IS-24 Mai Gano Hayaki na Ionization: Ƙayyadaddun Fassara da Fasaloli
Cikakkun bayanai na fasaha, fasali, aikace-aikace, da jagorar aiki don Potter IS-24 Ionization Smoke Detector. Koyi game da aikin sa, shigarwa, da hanyoyin gwaji don ingantaccen gano hayaki.
Preview Potter FSB-24 FFT-1000 Canja wurin Shigar Banki
Wannan jagorar tana ba da umarnin shigarwa da ƙayyadaddun fasaha don tukwane FSB-24 Switch Bank module, wanda aka ƙera don amfani tare da tsarin FFT-1000. Yana ba da cikakken bayanin kwatancen, bayanan fasaha, da hanyoyin shigarwa.
Preview Potter RA-6075R LCD Annunciator Installation Guide
Installation and configuration guide for the Potter RA-6075R LCD Remote Annunciator, detailing features, wiring, and address settings for the PFC-6075R fire alarm control panel.
Preview Potter PAD100-SLCE Addressable Loop Expander - Technical Specifications and Installation Guide
Detailed technical specifications, features, and installation instructions for the Potter PAD100-SLCE Addressable Loop Expander, a signaling line circuit expander designed for fire alarm systems.