RCYAGO BLE-9909

Manual mai amfani

RCYAGO BLE-9909 Smart Bluetooth pH/TDS/EC/Salinity/Temperature Tester

Model: BLE-9909 | Brand: RCYAGO

1. Gabatarwa

The RCYAGO BLE-9909 is a multi-parameter smart tester designed for precise measurement of pH, Total Dissolved Solids (TDS), Electrical Conductivity (EC), Salinity, and Temperature. This device integrates Bluetooth connectivity, allowing seamless data synchronization with the YINMIK mobile application for enhanced data management and analysis. It is suitable for various applications including domestic drinking water, hydroponics, laboratory testing, and aquariums.

RCYAGO BLE-9909 Smart Tester in use, measuring water in a glass.

Figure 1: RCYAGO BLE-9909 Smart Tester in operation.

2. Kayan Samfura

  • Multi-Parameter Measurement: Measures pH, TDS (ppm), EC (conductivity), Salinity (ppt), and Temperature.
  • Haɗin Bluetooth: Compatible with the YINMIK mobile application for real-time data transmission and control.
  • Cloud-Based Data Management: Enables easy saving, management, and sharing of test data, preventing data loss.
  • Daidaitawa ta atomatik: Features a 5-point calibration method for pH (Asian standard: pH 4.00, pH 6.86, pH 9.18; EU standard: pH 7.00, pH 10.01) ensuring high accuracy.
  • High Sensitivity Glass Probe: Provides a full measurement range of 0-14 pH with 0.01 pH resolution.
  • Cikakken Nuni: Large LCD screen displays multiple parameters simultaneously. App control allows for backlight adjustment.
  • Customizable Limits: The mobile application allows setting upper and lower limits for pH and EC. Abnormal values are highlighted in red.

3. Abubuwan Samfur

Familiarize yourself with the components of your BLE-9909 tester:

Fashe view of RCYAGO BLE-9909 showing components like battery, display, keys, immersion line, protective cap, and high-precision probe.

Hoto na 2: Fashe view of the BLE-9909 tester and its components.

  • 3*1.5V Button Battery: Tushen wuta don na'urar.
  • Nuni na baya: LCD screen for reading measurements.
  • Data Hold/Temperature Unit Conversion Key: Button to hold readings or switch temperature units.
  • Function Conversion/Calibration Key: Button to switch measurement modes or initiate calibration.
  • Maɓallin KUNNA/KASHE: Maɓallin wuta.
  • Immersion Line: Indicates the minimum immersion depth for accurate readings.
  • Tafiyar Kariya: Covers and protects the electrodes when not in use.
  • High-Precision Probe: Contains the sensors for measurement.
Close-up of the BLE-9909 electrodes, showing TDS/EC/Salinity sensor, External Reference, Temperature Sensor, and Glass PH Sensor.

Hoto 3: Cikakken bayani view of the BLE-9909 electrodes.

  • TDS/EC/Salinity Sensor: Measures Total Dissolved Solids, Electrical Conductivity, and Salinity.
  • External Reference: Reference electrode for stable measurements.
  • Sensor Zazzabi: Measures the temperature of the solution.
  • Glass PH Sensor: High-sensitivity sensor for pH measurements.

4. Saita

4.1 Shigar da Baturi

  1. Unscrew the battery compartment cap at the top of the device (refer to Figure 2).
  2. Insert three 1.5V button batteries, ensuring correct polarity.
  3. Securely screw the battery compartment cap back on.

4.2 Mobile App Connection (YINMIK App)

The BLE-9909 connects to your smartphone via Bluetooth for advanced features and data management.

  1. Download the "YINMIK" mobile application from your device's app store (iOS App Store or Google Play Store).
  2. Tabbatar cewa an kunna Bluetooth akan wayoyin ku.
  3. Turn on the BLE-9909 tester by pressing the "ON/OFF" key.
  4. Open the YINMIK app. The app will automatically search for and connect to the BLE-9909 device.
  5. Once connected, the app will display real-time measurement data.
RCYAGO BLE-9909 connected via Bluetooth to a smartphone displaying the YINMIK app interface.

Figure 4: Bluetooth data synchronization with the YINMIK mobile app.

5. Umarnin Aiki

5.1 Daukar Ma'auni

  1. Cire hular kariya daga lantarki.
  2. Kurkura da na'urar lantarki da ruwan da aka tace sannan a goge ta da kyallen takarda mai tsabta.
  3. Immerse the electrode into the solution to be tested, ensuring the immersion line is covered.
  4. Gently stir the solution and wait for the reading to stabilize on the LCD screen.
  5. Read the displayed values. The device will show pH, TDS/EC/Salinity, and Temperature.
  6. After measurement, rinse the electrode thoroughly with distilled water and replace the protective cap.

5.2 Switching Measurement Modes

Press the "MODE/CAL" key to cycle through different measurement parameters (pH, TDS, EC, Salinity). The active parameter will be indicated on the display.

5.3 Data Hold and Temperature Unit Conversion

Press the "HOLD/TEMP" key to hold the current reading on the display. Press it again to release. Long-press the "HOLD/TEMP" key to switch between Celsius (°C) and Fahrenheit (°F) temperature units.

6. Daidaitawa

Regular calibration ensures the accuracy of your pH measurements. The BLE-9909 supports a 5-point pH calibration.

6.1 Required Calibration Solutions

  • Asian Standard: pH 4.00, pH 6.86, pH 9.18
  • Matsayin EU: pH 7.00, pH 10.01

6.2 Tsarin daidaitawa

  1. Prepare the calibration buffer solutions (e.g., pH 6.86, pH 4.00, pH 9.18 for Asian standard).
  2. Turn on the tester and ensure it is in pH measurement mode.
  3. Kurkura wutar lantarki da ruwa mai narkewa sannan a bushe.
  4. Immerse the electrode into the first calibration solution (e.g., pH 6.86).
  5. Press and hold the "MODE/CAL" key until "CAL" appears on the display. The device will automatically recognize the buffer solution.
  6. Wait for the reading to stabilize and for the device to confirm calibration for that point.
  7. Remove the electrode, rinse with distilled water, and blot dry.
  8. Repeat steps 4-6 for the remaining calibration solutions in sequence.
  9. Once all points are calibrated, the device will automatically exit calibration mode.

Lura: For best accuracy, calibrate regularly, especially after prolonged storage or if readings appear inconsistent.

7. Data Management and App Features

The YINMIK mobile application provides comprehensive data management and additional control features.

  • Nunin Bayanai na Ainihin: View all measured parameters simultaneously on your phone screen.
  • Shigar Bayanai: Automatically save measurement data to the cloud, accessible anytime.
  • Bayanan Tarihi Review: Browse past measurements, including time and date stamps.
  • Ƙararrawa masu iya canzawa: Set upper and lower limits for pH and EC. The app will display values in red if they exceed these limits (see Figure 5).
  • Ikon Hasken Baya: Adjust the backlight of the device's LCD screen directly from the app.
  • Raba bayanai: Easily share your test results.
YINMIK app interface showing customizable pH and EC limits, with a red indicator for values exceeding the set range.

Figure 5: Setting custom measurement limits within the YINMIK app.

Multiple screenshots of the YINMIK app showing full display of readings, product parameter settings, calibration records, and automatic data storage.

Hoto 6: Samaview of YINMIK app features including data display, settings, and historical records.

8. Kulawa

8.1 Tsaftace Wutar Lantarki

After each use, rinse the electrode thoroughly with distilled or deionized water to prevent contamination and buildup. Do not wipe the glass bulb, as this can cause static electricity and damage the sensor. Gently blot dry with a lint-free tissue.

8.2 Adana

Always replace the protective cap after use. Ensure the sponge inside the cap remains moist with a few drops of pH storage solution or 3M KCl solution to keep the electrode hydrated. Never store the electrode dry or in distilled water, as this can shorten its lifespan.

8.3 Sauya Baturi

When the display becomes dim or the device fails to power on, replace the batteries as described in Section 4.1.

9. Shirya matsala

Matsala Dalili mai yiwuwa Magani
Karatuttuka mara inganci Electrode not calibrated; dirty electrode; expired calibration solution; damaged electrode. Calibrate the device (Section 6); clean the electrode (Section 8.1); use fresh calibration solutions; replace electrode if damaged.
Na'urar baya kunna Ƙananan batura ko matattu; shigarwar baturi ba daidai ba. Replace batteries (Section 8.3); ensure correct battery polarity (Section 4.1).
Matsalolin haɗin Bluetooth Bluetooth off on phone; app not open; device too far from phone; interference. Ensure Bluetooth is on; open YINMIK app; bring device closer to phone; restart both device and app.
Readings fluctuate excessively Electrode not fully immersed; air bubbles on electrode; solution not stable; damaged electrode. Ensure immersion line is covered; gently tap electrode to remove bubbles; wait for solution to stabilize; replace electrode if necessary.

10. Ƙayyadaddun bayanai

Siga Daraja
Lambar Samfura BLE-9909
Alamar RCYAGO
Girma 23.8 x 8 x 5.21 cm
Nauyi 168g ku
pH Measurement Range 0.00 - 14.00 pH
Tsarin pH 0.01 pH
Rage Ma'aunin Zazzabi Typically 0-60°C
Tushen wutar lantarki 3 x 1.5V Button Batteries
Haɗuwa Bluetooth (YINMIK Mobile App)

11. Garanti da Tallafawa

For warranty information, technical support, or service inquiries, please contact RCYAGO customer service through the official website or your point of purchase. Please have your model number (BLE-9909) and purchase date available when contacting support.

Mai ƙira: RCYAGO

First Available Date on Amazon.es: Disamba 24, 2021

Takardu masu alaƙa - BLE-9909

Preview DO-9100 Pen Type Intelligent Dissolved Oxygen Analyzer Instruction Manual
This document provides instructions for the DO-9100 pen type intelligent dissolved oxygen analyzer, covering its features, technical parameters, operation, maintenance, and troubleshooting.
Preview RCYAGO SGW07 Mai Amfani da Mai ƙidayar Ruwa Dual Water Timer
Cikakken jagorar mai amfani don RCYAGO SGW07 Dual Water Timer. Koyi game da samfurin ya ƙareview, ƙayyadaddun bayanai, shigarwa, shirye-shiryen shayarwa ta atomatik, shayarwar hannu, jinkirin ruwan sama, magance matsala, da matsayin baturi don tsarin ban ruwa na lambun ku.
Preview YINNIK BLE-9909 Bluetooth Water Quality Tester Instruction Manual
Comprehensive instruction manual for the YINNIK BLE-9909 Bluetooth 5-in-1 Water Quality Tester, covering operation, calibration, features, and specifications.
Preview Multiparamètre Portable YINMIK BLE-9909 Bluetooth 5*1 : Dabarun Bayani
Don YINMIK BLE-9909 est un testeur multiparamètre šaukuwa avec connectivité Bluetooth, conçu zuba mesurer avec pricision da pH, da conductivité, da TDS, da salinity da kuma yanayin zafi. Idéal pour les secteurs pharmaceutique, agroalimentaire et environnemental, il garantit des résultats fiables. Ce document détaille ses specifications techniques et son contenu d'emballage.
Preview YINMIK BLE-C600 Bluetooth 7-in-1 Mai gwada ingancin Ruwa: Umarni da ƙayyadaddun bayanai
Cikakken jagora don YINMIK BLE-C600 Bluetooth 7-in-1 Mai gwada ingancin Ruwa, saitin aiki, daidaitawa, fasali, da bayanin garanti.
Preview BLE-YC01 Bluetooth 6-in-1 Manual Mai amfani da Gwajin Pool
Cikakken jagorar mai amfani don BLE-YC01 Bluetooth 6-in-1 Pool Tester, mai rufe pH, EC, TDS, CL, ORP, da ma'aunin zafi. Ya ƙunshi cikakkun bayanai dalla-dalla, hanyoyin daidaitawa, sarrafa bayanai, da umarnin aiki don ingantaccen gwajin ingancin ruwa.