1. Gabatarwa
The SINOTIMER TM617 is a versatile digital programmable timer switch designed to automate the control of various electrical devices. It allows for precise scheduling of ON/OFF cycles over a 7-day period, making it suitable for a wide range of applications. This manual provides detailed instructions for the installation, operation, and maintenance of your TM617 timer switch.
Common applications include controlling street lights, neon signs, lamps, water heaters, air conditioners, billboards, electric ovens, boosters, sprayers, fillers, preheaters, agricultural equipment, and broadcasting equipment. The device features a built-in battery to preserve program settings during power interruptions, ensuring reliable operation. It is characterized by low power consumption, a high-precision CMOS chip, strong anti-interference capabilities, and user-friendly programming. The TM617 is IEC 60367 and CE certified.
2. Kayan Samfura
- Ideal for household and industrial applications, suitable for panel mounting.
- High load capacity: Supports up to 3500 Watts / 16 Amps with 1NO+1NC contact configuration.
- Flexible programming: Features 24-hour / 7-day weekly programming capabilities.
- Memory retention: Integrated rechargeable battery ensures program settings are saved during power outage.
- Accuracy: Automatic error correction of +/- 30 seconds per week.
- Multiple programs: Offers 16 ON/OFF program settings with repeat function.
- Manual control: Includes a manual ON/OFF override function.
- Clear display: Large LCD for easy viewing of time and program status.
3. Bayanan fasaha
| Samfura | TM-617 |
| Yanayin Zazzabi | -20 °C zuwa +50 °C |
| Tushen wutan lantarki | 100-130 V AC (Note: 220V variant also available) |
| Amfanin Wuta | 4.5 VA (MAX) |
| Nunawa | LCD |
| Switching Contact | 1 Changeover Switch (1NO+1NC) |
| Shirye-shirye | 16 ON/OFF settings per day or week |
| Ciwon ciki | 2 seconds/day (at 25°C) |
| Mafi qarancin tazara | Minti 1 |
| Ƙarfin Canjawa | 16 (8) A, 250 V AC |
| Ajiyayyen Ƙwaƙwalwa | 60 days (via internal battery) |
| Tsawon lokaci | Minti 1 zuwa 168 hours |
| Batirin ciki | 1.2V, 40mA |
| Average Error | ±1 second/24 hours (at 25°C) |
4. Saita da Shigarwa
Gargadin Tsaro: ƙwararren ma'aikacin lantarki ne kawai ya yi shigarwa. Tabbatar an katse wuta kafin shigarwa don hana girgiza wutar lantarki.
4.1 Cire kaya da dubawa
Carefully remove the TM617 timer switch from its packaging. Inspect the device for any signs of damage. The package should include the timer switch and mounting screws.

Figure 1: The SINOTIMER TM617 Digital Time Switch with its protective cover open, revealing the display and buttons. Two mounting screws are shown next to the device, indicating included accessories for installation.
4.2 Haɗawa
The TM617 is designed for panel mounting. Use the provided screws to secure the timer switch to a suitable panel or enclosure. Ensure adequate ventilation around the device.

Hoto 2: Na baya view of the SINOTIMER TM617 Digital Time Switch, illustrating the mounting points and terminal block for electrical connections. This view is crucial for proper installation.
4.3 Tsarin Waya
Refer to the wiring diagram below for correct electrical connections. Ensure all connections are secure and comply with local electrical codes.

Figure 3: Technical drawing of the SINOTIMER TM617 Digital Time Switch, showing its dimensions (72mm x 72mm x 48mm) and an exploded view. The diagram also includes a basic wiring schematic, indicating where to connect the power input and load output.
The diagram typically shows terminals for power input (L, N) and load output (L, N, or switched live). The TM617 has a 1NO+1NC contact, meaning it can switch between two states. Consult the markings on the device for specific terminal assignments.
5. Umarnin Aiki
The TM617 features an intuitive button layout for setting the time and programming schedules.

Hoto 4: Gaba view of the SINOTIMER TM617 Digital Time Switch, highlighting the LCD display and the various control buttons for setting time and programming functions.
5.1 Ayyukan Maɓalli
- Alamar agogo: Used to set the current time and day.
- P: Program button, used to enter and navigate through programming modes.
- D+: Day button, used to adjust the day of the week.
- H+: Hour button, used to adjust the hour.
- M+: Minute button, used to adjust the minute.
- C/R: Cancel/Recall or Reset button. Press to clear settings or reset the device.
- Ikon hannun hannu: Manual override button, to switch the output ON/OFF manually, overriding current program.
5.2 Initial Setup and Reset
Upon first use or after a prolonged power outage, the display may be blank or show incorrect time. Press the C/R button (often recessed, requiring a pointed object) to reset the device. The internal battery will charge once power is supplied to the unit.
5.3 Saita Lokacin Yanzu da Ranar
- Latsa ka riƙe Alamar agogo maballin.
- Yayin rike da Alamar agogo maballin, latsa D+ don saita ranar mako na yanzu.
- Yayin rike da Alamar agogo maballin, latsa H+ don saita lokaci na yanzu.
- Yayin rike da Alamar agogo maballin, latsa M+ don saita minti na yanzu.
- Saki da Alamar agogo Maɓalli. Lokaci ya yi yanzu.
5.4 Shirye-shirye Zagaye na Kunnawa/Kashewa
The TM617 allows for up to 16 ON/OFF programs. Each program consists of an ON time and an OFF time, and can be set for specific days or groups of days.
- Danna maɓallin P button once to enter program setting mode. The display will show "1 ON".
- Latsa D+ to select the desired day(s) for this program. Options typically include individual days (MO, TU, WE, etc.), weekdays (MO TU WE TH FR), weekends (SA SU), or all days (MO TU WE TH FR SA SU).
- Latsa H+ don saita sa'ar ON.
- Latsa M+ don saita minti na ON.
- Danna maɓallin P button again. The display will show "1 OFF".
- Repeat steps 2-4 to set the OFF time for the first program.
- Danna maɓallin P button again to move to the next program ("2 ON"). Repeat the process for up to 16 programs.
- To exit program setting mode and return to the current time display, press the Alamar agogo maballin.
5.5 Sauke Manual
Danna maɓallin Ikon hannun hannu button to manually switch the output state (ON/OFF) without affecting the programmed schedule. This is useful for temporary control. The display will indicate the manual override status (e.g., "ON" or "OFF" with a hand icon).
6. Kulawa
The SINOTIMER TM617 is designed for low maintenance. Follow these guidelines to ensure optimal performance:
- Tsaftacewa: Shafa na'urar tare da laushi, bushe bushe. Kada a yi amfani da masu tsabtace abrasive ko kaushi.
- Baturi: The internal rechargeable battery is designed for long life and typically does not require replacement. It charges automatically when the device is powered. If the display remains blank after power is restored, allow some time for the battery to charge.
- Muhalli: Ensure the operating environment stays within the specified temperature range (-20 °C to +50 °C) and is free from excessive dust or moisture.
7. Shirya matsala
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| Nuni babu komai. | No power supply; internal battery discharged. | Check power connections. Ensure the device is receiving power. Allow time for the internal battery to charge. Press the C/R button to reset. |
| Timer does not switch ON/OFF as programmed. | Incorrect program settings; manual override active; incorrect current time/day. | Verify program settings (ON/OFF times, days). Check if manual override is active and switch to AUTO mode if necessary. Ensure current time and day are set correctly. |
| Lokaci bai yi daidai ba. | Minor drift (normal for electronic timers); device needs reset. | The device has an automatic error correction of +/- 30 seconds per week. If significantly off, reset the device using the C/R button and re-set the current time. |
| Load does not turn ON/OFF. | Incorrect wiring; faulty load; timer malfunction. | Check wiring according to the diagram. Test the load directly to ensure it is functional. If all else fails, the timer may be faulty and require replacement. |
8. Bayanin Tsaro
- Always disconnect power before installing, wiring, or servicing the device.
- Do not exceed the maximum load capacity of 16A / 3500W.
- Ensure proper grounding and adherence to all local electrical codes.
- Do not expose the device to water or extreme humidity.
- Do not attempt to open or repair the device yourself. Refer to qualified personnel.
- A kiyaye nesa da yara.
9. Garanti da Tallafawa
For warranty information and technical support, please refer to the purchase documentation or contact your retailer. SINOTIMER products are designed for reliability, and support is available for any operational issues or defects.
Don ƙarin taimako, zaku iya ziyartar shafin SINOTIMER Brand Store on Amazon.