Thank you for choosing the REPTITRIP Reptile Fogger. This device is designed to provide optimal humidity levels for amphibians, reptiles, and ecological rainforest terrariums. It features constant humidity control, a timer function, and a 4-liter capacity, ensuring a stable and healthy environment for your pets. Please read this manual thoroughly before operation to ensure proper use and maintenance.

REPTITRIP Reptile Fogger with remote control and flexible hose

Image 1: The REPTITRIP Reptile Fogger, showing the main unit, flexible hose, remote control, and external sensor.

2. Umarnin Tsaro

  • Always unplug the unit from the power outlet before filling, cleaning, or performing any maintenance.
  • Kada a nutsar da babban naúrar cikin ruwa ko wasu ruwaye.
  • Tabbatar cewa igiyar wutar lantarki ba ta lalace ba kuma an sanya ta a inda ba za a iya tuntuɓe ta ko ja ta ba.
  • Use only clean, distilled, or demineralized water to prevent mineral buildup and ensure optimal performance.
  • Ka kiyaye yara da dabbobin da ba za su iya isa ba.
  • Kada a toshe hanyar fitar da hazo ko hanyoyin shigar iska.
  • Operate the unit on a stable, flat surface to prevent tipping.
  • If the unit emits unusual sounds, smells, or smoke, unplug it immediately and discontinue use.

3. Abubuwan Kunshin

Da fatan za a duba kunshin don abubuwa masu zuwa:

  • REPTITRIP Reptile Fogger Main Unit (4L water tank)
  • Flexible Adjustable Hose
  • Ikon nesa
  • External Temperature & Humidity Sensor Probe
  • Jagorar mai amfani (wannan takaddar)

4. Abubuwan Samfur da Tsari

Familiarize yourself with the different parts of your REPTITRIP Reptile Fogger.

  1. Tankin ruwa (yawanci 4l)
  2. Base Unit with Control Panel (Touch Screen)
  3. Mist Outlet Nozzle
  4. Mai Haɗin Hose Mai Sauƙi
  5. Port Sensor Port
  6. Igiyar Wutar Lantarki
  7. Ikon nesa
REPTITRIP Reptile Fogger showing two operation modes: Time Setting and Humidity Control

Image 2: The fogger's display highlighting the two primary operation modes: Time Setting and Humidity Control.

5. Saita

5.1 Cire kaya da Sanyawa

  • Cire duk kayan marufi.
  • Place the fogger on a flat, stable surface near the terrarium. Ensure there is enough space around the unit for proper ventilation.

5.2 Cika Tankin Ruwa

  1. Lift the water tank from the base unit.
  2. Cire murfin a kasan tankin.
  3. Fill the tank with clean, distilled, or demineralized water. Do not exceed the maximum fill line.
  4. A sake manne murfin da kyau.
  5. Sanya tankin ruwan da aka cika a kan na'urar tushe, tabbatar da cewa an zaunar da shi daidai.

5.3 Connecting the Hose and Sensor

  • Connect one end of the flexible hose to the mist outlet nozzle on the top of the fogger.
  • Route the other end of the hose into your terrarium, positioning the mist outlet where desired.
  • Plug the external temperature and humidity sensor probe into its designated port on the base unit.
  • Place the sensor inside the terrarium, away from the direct mist path, to accurately measure ambient conditions.

5.4 Haɗin Wuta

  • Plug the power cord into a standard electrical outlet. The unit will beep, and the display will illuminate.

6. Aiki

6.1 Control Panel da Remote Control

The fogger can be operated via the touch screen control panel on the base unit or the included remote control. Both offer similar functionalities.

  • SET/ON/OFF Button: Powers the unit on/off and enters setting modes.
  • Ok Button: Confirms selections in setting modes.
  • Maɓallan '+' da '-': Adjust values (time, humidity, mist level) and navigate menus.

6.2 Hanyoyin Aiki

The REPTITRIP Fogger offers two main operating modes: Aikin Lokaci kuma Yanayin Humidity. These modes operate independently.

Multi-purpose use of REPTITRIP Reptile Fogger for indoor humidity control, reptile humidification, and plant growth

Image 3: The fogger's versatility for various applications, including terrarium humidification and indoor plant care.

6.2.1 Ayyukan Lokaci

This mode allows you to schedule humidification cycles based on specific intervals and durations.

  1. Danna maɓallin SET button to enter the timing settings.
  2. Yi amfani da '+' kuma '-' maballin don saita Yawanci (interval between humidification cycles, from 1 hour to 7 days). Press OK don tabbatarwa.
  3. Saita Tsawon lokaci (how long the fogger will mist during each cycle, from 10 seconds to 1 hour). Press OK don tabbatarwa.
  4. The display will show the next humidification time and current humidity.

6.2.2 Humidity Mode (Constant Humidity)

This mode maintains a desired humidity range by automatically turning the fogger on and off based on sensor readings.

  1. Danna maɓallin SET button until the humidity setting appears.
  2. Yi amfani da '+' kuma '-' maballin don saita Mafi qarancin Humidity kashi daritage. Latsa OK don tabbatarwa.
  3. Saita Matsakaicin Humidity kashi daritage. Latsa OK don tabbatarwa.
  4. The fogger will now automatically activate when humidity drops below the minimum and stop when it reaches the maximum. The current humidity value will be displayed.
Graph showing how Reptitrip humidifier maintains target humidity compared to traditional humidifiers

Image 4: A graphical representation demonstrating the REPTITRIP fogger's ability to maintain a consistent humidity range.

6.3 Fog Adjustment

The fogger offers three levels of mist output, allowing you to control the rate of humidification.

  • In either Timing or Humidity mode, use the '+' kuma '-' buttons on the control panel or remote to cycle through the three mist levels.
  • Mist levels correspond to approximately 100ml/hr, 200ml/hr, and 300ml/hr water consumption.
Three Reptitrip humidifiers showing different mist output levels

Image 5: Visual representation of the three adjustable mist output levels.

6.4 Kashewa ta atomatik

The REPTITRIP Fogger is equipped with an automatic shut-off feature. When the water level in the tank is too low, an icon will appear on the display, and the atomizer will automatically power down to prevent damage and ensure safety.

7. Kulawa

Regular cleaning is essential for optimal performance and longevity of your fogger.

7.1 Cleaning the Water Tank and Base Unit

  1. Cire na'urar sannan ka cire tankin ruwa.
  2. Empty any remaining water from the tank and the base unit.
  3. Wipe the inside of the water tank and the base unit (especially the transducer/atomizer disc) with a soft cloth.
  4. For mineral buildup, use a solution of white vinegar and water (1:1 ratio). Let it soak for 15-20 minutes, then gently scrub with a soft brush and rinse thoroughly.
  5. Tabbatar cewa duk sassan sun bushe gaba ɗaya kafin sake haɗawa.

7.2 Cleaning the Hose and Sensor

  • Periodically check the flexible hose for any condensation or debris. Clean with a mild soap and water solution if necessary, and rinse thoroughly.
  • Wipe the external sensor probe with a dry, soft cloth. Do not use harsh chemicals or immerse the sensor in water.

8. Shirya matsala

If you encounter issues with your REPTITRIP Fogger, please refer to the following common problems and solutions:

MatsalaDalili mai yiwuwaMagani
No mist is being produced.Low water level; Unit not powered on; Atomizer disc dirty or damaged.Refill water tank; Ensure unit is plugged in and powered on; Clean atomizer disc (refer to Maintenance).
Display is flashing or unit is beeping.Low water warning; Sensor error; Internal malfunction.Check water level and refill if necessary. Ensure sensor is properly connected. If problem persists after refilling and checking sensor, unplug and plug back in. If still flashing/beeping, contact customer support.
Humidity levels are not increasing sufficiently.Mist output too low; Terrarium too large/leaky; Sensor placement.Increase mist output level; Check terrarium for excessive ventilation; Reposition sensor away from direct mist.
White dust around the unit.Using hard water.Use only distilled or demineralized water. Clean the unit regularly to remove mineral buildup.

9. Ƙayyadaddun bayanai

SiffarDaki-daki
AlamarJAWABI
Lambar SamfuraDA-168
LauniBaki
Girman samfur18.54 x 18.54 x 26.67 cm
Nauyin Abu1.47 kg
Iyawa4 lita (galan 1.06)
Kayan abuFilastik
Lokacin guduHar zuwa awanni 20 (a mafi ƙarancin saitin hazo)
Siffofin MusammanAuto Shut Off, Constant Humidity, Timer Function, Remote Control, Touch Screen, Temperature & Humidity Display
Mist Output Levels3 (approx. 100/200/300 ml/hr)

10. Garanti da Tallafawa

This product typically comes with a limited warranty. Please refer to your purchase documentation for specific warranty terms and duration. For technical support, troubleshooting assistance beyond this manual, or warranty claims, please contact the seller or REPTITRIP customer service through the platform where the product was purchased.

Manufar Komawa: The standard return policy for this product is 30 days from the date of purchase for refund or replacement.

Takardu masu alaƙa - DA-168

Preview Reptitrip Reptile Heat Mat with Digital Thermostat User Manual and Specifications
Comprehensive user manual for the Reptitrip Reptile Heat Mat with Digital Thermostat, covering setup, programming, specifications, safety instructions, and warranty information. Includes details on various Reptitrip products.
Preview ReptiTrip Digital Temp-Time Controller User Manual
User manual for the ReptiTrip Digital Temp-Time Controller (SOP24), detailing its features, specifications, setup, programming, and warranty information. This device is a dual-relay output temperature controller suitable for various applications like aquariums, pet breeding, and incubation.
Preview Klipsch Reference Premiere Series Manual Mai Amfani - Saita, Wuri, da Haɗi
Cikakken jagorar mai amfani don masu magana da Klipsch Reference Premiere Series, saitin rufewa, sanya ɗaki, jagororin haɗi, Haɗin Dolby Atmos, kulawa, da rajistar samfur. Ya haɗa da cikakkun bayanai na ƙira don RP-8060FA, RP-8000F, RP-6000F, RP-5000F, RP-4000F, RP-600M, RP-500M, RP-400M, RP-502S, RP-402S, RP-500C, RP-500C RP-600C, RP-500C, RP-400C, da RP-160M.
Preview Klipsch Reference Preferences Premier User Manual
Littafin mai amfani don Klipsch Reference Preference speakers, rufe saitin, jeri, haɗi, kulawa, da bayanin garanti. Yana da cikakkun bayanai dalla-dalla da zane-zane don samfura daban-daban ciki har da RP-8060FA, RP-8000F, RP-6000F, RP-5000F, RP-4000F, RP-600M, RP-500M, RP-400M, RP-502S, 402RP-504RP, RP-500S RP-404C, RP-600C, RP-500C, da RP-400C.