Gabatarwa
Thank you for choosing the Rebel POWER-800 RB-4012 Pure Sine Wave Inverter. This device is designed to convert 12V DC power from a battery into 230V AC pure sine wave power, suitable for a wide range of electronic appliances. It also features an integrated charging function, allowing it to act as an emergency power supply. Please read this manual thoroughly before installation and operation to ensure safe and efficient use of your inverter.
Umarnin Tsaro
- Always connect the inverter to a 12V DC battery system. Connecting to other voltages na iya haifar da lalacewa.
- Ensure proper ventilation around the inverter to prevent overheating. Do not block ventilation openings.
- Keep the inverter away from water, moisture, flammable materials, and direct sunlight.
- Kada a buɗe inverter casing. Babu kayan aikin da za a iya amfani da su a ciki. A miƙa duk kayan aikin ga ma'aikata masu ƙwarewa.
- Ensure all connections are secure and correctly polarized to avoid electrical hazards.
- Disconnect the battery before performing any maintenance or cleaning.
- This device is equipped with built-in protection against overload, short circuit, overvoltage, ƙiratage, and overheating. However, always operate within specified limits.
Samfurin Ƙarsheview
Familiarize yourself with the components of your Rebel POWER-800 RB-4012 inverter.

Hoto 1: Gaban Gaba
This image shows the front of the Rebel POWER-800 inverter, featuring the digital LED display, two AC output sockets, and the DC input cables (red and black) for battery connection. The display provides real-time status information.

Hoto 2: Rear Panel
This image displays the rear of the Rebel POWER-800 inverter. It includes a cooling fan for heat dissipation, two AC output sockets, the AC input port for grid connection, and a circuit breaker for protection.
Ƙayyadaddun bayanai
| Siffar | Ƙayyadaddun bayanai |
|---|---|
| Ƙarfin Ƙarfi | 500 W |
| Nau'in Baturi | 12 V DC |
| Matsakaicin Baturi Voltage | 15 V DC |
| Shigar da Voltage Range (AC) | 180 ~ 275V AC |
| Mitar shigarwa | 45 ~ 60 Hz |
| Fitarwa Voltage Range (AC) | 230 V AC +/-8% |
| Yawan fitarwa | 50/60 Hz +/- 0.5 Hz |
| Fitar Waveform | Tsarkakakken Sine Sine |
| Output Efficiency (DC to AC) | >> 85% |
| Cajin Baturi Yanzu | Max. 10 A ba |
| Lokacin Canjawa | <= 4 ms |
| Siffofin Kariya | Overload, Short Circuit, Overvoltage, Undervoltage, Yawan zafi |
| Yanayin Aiki | 0-40 ° C |
| Danshi | 10-90% |
| Girma (L x W x H) | 215 x 265 x 100 mm |
| Nauyi | 4.7 kg |
Saita
- Haɗin baturi: Connect the red DC cable from the inverter to the positive (+) terminal of your 12V battery. Connect the black DC cable to the negative (-) terminal. Ensure connections are tight and secure. Incorrect polarity will damage the unit.
- AC Input (Grid Connection): If you intend to use the charging function or have the inverter act as an emergency power supply, connect the AC input cable to a standard 230V AC wall outlet.
- AC Output (Device Connection): Plug your 230V AC appliances into the output sockets on the inverter's front or rear panel. Ensure the total power consumption of connected devices does not exceed the inverter's rated power of 500W.
- Wuri: Place the inverter on a stable, flat surface in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure there is adequate space around the cooling fan.
Umarnin Aiki
- Kunna Wuta: After all connections are made, switch on the inverter. The LED display will illuminate, showing the current status, including input voltage, fitarwa voltage, and battery charge level.
- Sa Ido Kan Nuni: The LED display provides real-time information. Monitor it for battery status, AC input/output voltage, da kuma duk wani alamar kuskure.
- Aikin Caji: When the inverter is connected to both a battery and an AC grid source, it will automatically charge the connected 12V battery. The display will indicate the charging status.
- Samar da Wutar Gaggawa: Idan akwai iko kutage (loss of AC grid input), the inverter will automatically switch to battery power, providing continuous 230V AC output to connected devices within 4ms.
- Kashe Wuta: To turn off the inverter, first disconnect all AC appliances, then switch off the inverter, and finally disconnect the AC input cable (if connected) and battery cables.
Kulawa
- Tsaftacewa: Regularly clean the exterior of the inverter with a soft, dry cloth. Do not use liquid cleaners or solvents. Ensure ventilation openings are free from dust and debris.
- Kulawar Baturi: Ensure your 12V battery is well-maintained and charged. The inverter's charging function helps maintain battery health when connected to the grid.
- Duban haɗi: Periodically check all electrical connections (DC and AC) to ensure they remain tight and free from corrosion.
- Ajiya: If storing the inverter for an extended period, disconnect it from the battery and AC power. Store in a cool, dry place.
Shirya matsala
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| Babu fitarwar wuta | Batirin bai haɗa ba ko kuma ƙaramin voltage; Inverter switched off; Blown fuse/circuit breaker. | Check battery connections and charge level; Ensure inverter is switched on; Reset circuit breaker or check internal fuse (if accessible and safe). |
| Gargadi mai yawa | Connected appliances exceed 500W rated power. | Reduce the load by disconnecting some appliances. |
| Gargadi mai zafi fiye da kima | Rashin samun iska mai kyau; Yawan kaya. | Ensure adequate airflow around the inverter; Reduce load. Allow unit to cool down. |
| An kunna kariyar gajeriyar kewayawa | Short circuit in connected appliance or wiring. | Disconnect all appliances and check for faulty wiring or devices. Reconnect one by one to identify the faulty item. |
| Baturi baya caji | AC input not connected; AC input voltage too low/high; Faulty battery. | Ensure AC input cable is securely connected to a live outlet; Check AC input voltage; Test battery condition. |
Garanti da Taimako
Rebel products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or contact your retailer. Keep your purchase receipt as proof of purchase.