Ortis KJ-027

Ortis Automatic Water Level Controller KJ-027 Instruction Manual

Saukewa: KJ-027

1. Gabatarwa

This manual provides detailed instructions for the installation, operation, and maintenance of your Ortis Automatic Water Level Controller, Model KJ-027. This device is designed to manage water levels in various applications, including aquariums, fish tanks, swimming pools, and sump pump pits, offering automatic water refilling, draining, and water change functionalities.

2. Bayanin Tsaro

3. Samfurin Ya Ƙareview da kuma abubuwan da aka gyara

The Ortis Automatic Water Level Controller KJ-027 consists of a main control unit, two water level sensors (HI and LO), and power cords. The control unit features power outlets for connecting pumps, control buttons, and an LED display.

Ortis Automatic Water Level Controller main unit with sensors

Figure 3.1: Main components of the Ortis Automatic Water Level Controller, including the control unit, HI and LO sensors, and power plug.

Dalla-dalla view of Ortis Water Level Controller buttons and LED display

Figure 3.2: Close-up of the control unit showing the MUTE, MANUAL, FILL, DRAIN, AUTO buttons, and the LED display. Also highlights the adjustable sensors and 304 stainless steel sensor material.

4. Saita da Shigarwa

The Ortis Automatic Water Level Controller is designed for easy installation without plumbing modifications. All necessary installation tools are included.

4.1 Mounting the Control Unit

Ortis Water Level Controller mounting options

Figure 4.1: Illustration of mounting the control unit using screws or adhesive pads.

4.2 Sanya Sensor

The HI and LO sensors detect water levels. Their placement determines the operating range for filling and draining. The sensors are adjustable from 1/4 inch to 20 inches.

HI and LO water level sensors installed in an aquarium

Hoto na 4.2: Example of HI and LO sensors installed within an aquarium to monitor water levels.

Ortis Water Level Controller features including adjustable sensors

Hoto 4.3: Samaview of product features, highlighting the adjustable range of the sensors.

4.3 Connecting Pumps

5. Umarnin Aiki

The controller offers four operating modes: Automatic Water Change, Fill, Drain, and Manual.

5.1 Zaɓin Yanayin

Use the buttons on the control unit to select the desired mode:

5.2 Automatic Water Change Mode

In AUTO mode, the controller manages both draining and refilling to perform a water change. The system will drain water until the LO sensor is exposed, then refill until the HI sensor is reached.

Diagram of Auto Mode for Automatic Water Change in an aquarium setup

Figure 5.1: Illustration of the automatic water change process using the AUTO mode, showing the controller connected to both drain and fill pumps.

5.3 Fill Mode

In FILL mode, the controller maintains the water level by activating the refill pump when the water drops below the LO sensor and deactivating it when the water reaches the HI sensor.

Diagram showing how the HI-LO pump switch works for filling a fish tank

Figure 5.2: Illustration of the fill operation. The pump turns on when water is below the LO sensor and turns off when it reaches the HI sensor.

5.4 Drain Mode

In DRAIN mode, the controller activates the drain pump when the water level reaches the HI sensor and deactivates it when the water drops below the LO sensor. This mode is also suitable for sump pump applications.

Diagram showing how the HI-LO pump switch works in sewage pits for draining

Figure 5.3: Illustration of the drain operation in a sump pit. The pump turns on when water reaches the HI sensor and turns off when it drops below the LO sensor.

5.5 Manual Control Mode

The MANUAL mode allows you to manually activate or deactivate the connected pumps.

5.6 Alarm and Mute Function

The controller includes a built-in alarm to notify you of potential issues such as pump failure or blockage. The LED display provides clear indications.

6. Kulawa

7. Shirya matsala

MatsalaDalili mai yiwuwaMagani
Mai sarrafawa bai kunna ba.Babu wutar lantarki; sako-sako da haɗi.Check power plug connection; ensure outlet is functional.
Pump not activating in automatic mode.Incorrect mode selected; sensor not triggered; pump malfunction; clogged hose.Verify mode (FILL/DRAIN/AUTO); check sensor placement and water level; test pump manually; inspect hoses for blockages.
Alarm sounding.Pump failure; discharge pipe blockage; water level not changing as expected.Inspect pumps and plumbing; clear any blockages; verify sensor function. Press MUTE to silence.
Water level not maintained accurately.Improper sensor placement; sensor malfunction.Adjust HI/LO sensor positions; ensure sensors are clean and unobstructed.

8. Ƙayyadaddun bayanai

AlamarOrtis
Lambar SamfuraKJ-027
Kayan abuStainless Steel (Sensors)
Tushen wutar lantarkiCorded Electric
Max Pump Capacity2 Hp, 16A
Nauyin AbuKilogram 0.65 (kilo 1.42)
Girman Kunshin9.61 x 3.78 x 3.23 inci
Sensor Adjustment Range1/4 inch to 20 inches

9. Garanti da Tallafawa

For warranty information and technical support, please refer to the product packaging or contact the manufacturer directly. Details regarding specific warranty periods and support channels are typically provided at the point of purchase or on the manufacturer's official website.