1. Gabatarwa
This instruction manual provides essential information for the safe and effective use of the UNI-T UPO1102 100MHz 2-Channel Digital Oscilloscope. The UPO1102 is a versatile instrument designed for electronic and electrical measurements, featuring a 100MHz bandwidth, 1 GSa/s real-time sample rate, 56 Mpts memory depth, and a 7-inch display. It incorporates Ultra Phosphor technology for enhanced waveform display and analysis capabilities.
Please read this manual thoroughly before operating the device to ensure proper functionality and to prevent damage.
2. Bayanin Tsaro
Always observe the following safety precautions to avoid personal injury and prevent damage to the instrument or other connected devices.
- Haɗa igiyar wutar lantarki zuwa madaidaicin tushe mai tushe.
- Do not operate the oscilloscope in wet or damp yanayi.
- Tabbatar samun iska mai kyau don hana zafi.
- Do not open the instrument casing; tura sabis ga ma'aikata masu ƙwarewa.
- Use only specified probes and accessories.
- Observe all terminal ratings to prevent fire or shock hazard.
3. Samfurin Ya Ƙareview
3.1 Gaban gaba

Figure 3.1: Front Panel of UPO1102 Oscilloscope
The front panel features the main display, various control knobs and buttons for waveform adjustment, trigger settings, and menu navigation. Input channels CH1 and CH2 are located at the bottom right.
3.2 Rear Panel

Figure 3.2: Rear Panel of UPO1102 Oscilloscope
The rear panel includes the AC power input, USB ports for data transfer and printing, and ventilation grilles to ensure proper cooling during operation.
3.3 Girma

Figure 3.3: UPO1102 Oscilloscope Dimensions
The physical dimensions of the UPO1102 are approximately 13.23 inches (width) x 6.46 inches (height) x 4.13 inches (depth).
4. Saita
4.1 Cire kaya da dubawa
Upon receiving your UPO1102 oscilloscope, carefully unpack all components and inspect them for any signs of damage. Retain the packaging for future transport or storage.
Daidaitaccen Na'urorin haɗi:
- Oscilloscope Probe (UT-P04) x 2
- Igiyar Wutar Lantarki
- USB2.0 Printing Cable
- English Download Guide
- Multi-language Safety Manual
- Calibration Report (COC)
4.2 Haɗin Wuta
- Ensure the oscilloscope is placed on a stable, level surface with adequate ventilation.
- Connect the provided power cord to the AC power input on the rear panel of the oscilloscope.
- Haɗa ɗayan ƙarshen igiyar wutar lantarki zuwa cikin tashar wutar lantarki ta AC da aka gina.
- Press the power button on the front panel to turn on the oscilloscope.
4.3 Probe Connection and Compensation
Before taking measurements, it is crucial to compensate the probes to ensure accurate readings.
- Connect a probe to one of the input channels (CH1 or CH2) on the front panel.
- Connect the probe tip to the "Probe Comp" terminal and the ground clip to the ground terminal next to it.
- Danna maɓallin Mota button. The oscilloscope will automatically adjust the settings to display the compensation signal.
- Observe the square wave displayed on the screen. If the waveform is not a perfect square (over-compensated or under-compensated), adjust the trimmer on the probe body using a non-metallic tool until a flat-top square wave is achieved.
- Repeat for the second probe if using both channels.

Figure 4.1: Probe Compensation Waveform
A correctly compensated probe displays a clean square wave. Adjust the probe's trimmer if the waveform shows overshoot or undershoot.
5. Umarnin Aiki
5.1 Abubuwan Gudanarwa na asali
- Maɓallin Wuta: Located on the front panel, used to turn the device on or off.
- Multipurpose Knob: Used for menu navigation and parameter adjustment. Press to confirm selections.
- Vertical Controls (CH1, CH2): Adjust vertical position and scale (volts/division) for each channel. "Push to Zero" resets position, "Push to Fine" enables fine adjustment.
- Sarrafa a kwance: Adjust horizontal position and time base (seconds/division). "Push to Zero" resets position, "Push to Zoom" enables horizontal zoom.
- Trigger Controls: Set the trigger level, mode (Auto, Normal, Single), and force a trigger event.
- Button Mota: Automatically adjusts vertical, horizontal, and trigger settings to display a stable waveform.
- Run/Stop Button: Starts or stops waveform acquisition.
5.2 Waveform Acquisition and Display
The UPO1102 features a 7-inch display and Ultra Phosphor technology for clear waveform visualization, even with complex signals.

Figure 5.1: Ultra Phosphor Display
Ultra Phosphor technology provides a gradient display, where brighter areas indicate more frequent occurrences of the waveform, helping to visualize signal anomalies and variations.

Figure 5.2: Multi-Channel Waveform Display
The UPO1102 can display and analyze two channels simultaneously, allowing for comparison of different signals.
5.3 Ayyukan Aunawa
- Ma'aunin Ma'auni: Activate the "Cursor" function to measure time and voltage parameters within a specified area on CH1, CH2, MATH, or REF waveforms.
- FFT Analysis: The UPO1102 features 1Mpts FFT sampling points, enabling frequency domain analysis. Access the FFT function to set frequency range, detection mode, and spectrum marking.
- Navigation Functions: Utilize time navigation, marker navigation, and segment navigation for detailed waveform inspection.

Figure 5.3: FFT Spectrum Analysis
The FFT function transforms time-domain signals into the frequency domain, useful for analyzing harmonic content and noise.
5.4 Digital Decoding
The innovative hardware decoding feature allows for real-time decoding of serial bus protocols. With a deep storage of 56 Mpts, decoding speed is maintained at millisecond levels, preventing delays when viewing decoded data. This function does not affect the waveform refresh rate, maintaining the digital fluorescence display effect.

Figure 5.4: Digital Decoding Example
The decoding feature displays protocol information directly on the screen, simplifying debugging of serial communications.
5.5 Adana bayanai da Haɗuwa
- Zurfin Ƙwaƙwalwa: The UPO1102 offers a 56 Mpts memory depth, allowing for capture of long signal durations at high sampda rates.
- Haɗin USB: Use the provided USB2.0 printing cable to connect the oscilloscope to a computer for data transfer or direct printing.
- Web Access and Control: Na'urar tana tallafawa WEB access and control, along with SCPI (Standard Commands for Programmable Instruments) for remote operation and automation.

Figure 5.5: Memory Depth Indication
A large memory depth is crucial for capturing transient events or long sequences of data without losing detail.
6. Kulawa
6.1 Babban Kulawa
- Keep the instrument clean and dry. Avoid operating in dusty or humid environments.
- Protect the display from scratches and impacts.
- Do not block the ventilation openings on the rear panel.
6.2 Tsaftacewa
To clean the exterior of the oscilloscope:
- Disconnect the power cord and all probes/cables.
- Yi amfani da yadi mai laushi dampened with mild detergent and water. Do not use abrasive cleaners or solvents.
- For the display, use a soft, lint-free cloth specifically designed for electronic screens.
- Ensure the instrument is completely dry before reconnecting power.
7. Shirya matsala
This section addresses common issues you might encounter with the UPO1102 oscilloscope. For problems not listed here, contact UNI-T customer support.
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| Babu nuni bayan kunna wuta. | Power cord not connected, power outlet faulty, instrument fault. | Check power cord connection. Test power outlet. If problem persists, contact support. |
| No waveform displayed. | Probe not connected, signal too small/large, trigger not set correctly, channel off. | Ensure probe is connected to signal source. Press Mota button. Adjust vertical scale (Volts/Div) and horizontal scale (Sec/Div). Check trigger level. Ensure channel is enabled. |
| Unstable waveform. | Trigger level incorrect, trigger mode unsuitable, signal noise. | Adjust trigger level. Try different trigger modes (e.g., Normal or Single). Reduce noise in the signal path. |
| Incorrect measurements. | Probe compensation incorrect, probe attenuation setting wrong, measurement settings incorrect. | Perform probe compensation (Section 4.3). Verify probe attenuation setting matches physical probe (e.g., 1X, 10X). Check measurement parameters. |
8. Ƙayyadaddun bayanai
| Siga | Daraja |
|---|---|
| Bandwidth | 100 MHz |
| Tashoshi | 2 |
| Real-lokaci Sampda Rate | 1 GSa/s |
| Zurfin ƙwaƙwalwa | 56 Mpts |
| Waveform Capture Rate | 500,000 wfm/s |
| Nunawa | 7-inci |
| FFT Sampling Points | 1 Mpts |
| Girman samfur | 13 x 4 x 6 inci (kimanin. 330 x 102 x 152 mm) |
| Nauyin Abu | 8.13 fam (kimanin 3.69 kg) |
| Mai ƙira | UNI-T |
| ASIN | B0D7F2D9MS |
| Kwanan Wata Farko Akwai | Yuni 19, 2024 |
9. Garanti da Tallafawa
For warranty information, technical support, or service inquiries regarding your UNI-T UPO1102 oscilloscope, please refer to the official UNI-T website ko tuntuɓi sashen sabis na abokin ciniki.
UNI-T Official Store: Visit the UNI-T Store on Amazon
Please have your product model (UPO1102) and ASIN (B0D7F2D9MS) available when contacting support.