Pedrollo TOP 2

Pedrollo TOP 2 Submersible Pump User Manual

Model: TOP 2

1. Gabatarwa

The Pedrollo TOP 2 submersible pump is designed for pumping clear water without abrasive particles. This 0.5 HP, 115 Volt pump is engineered for ease of use and reliable operation, featuring total motor cooling and a double mechanical seal on the shaft for enhanced safety and durability.

It is particularly suitable for emergency draining of small flooded areas such as basements, garages, and fountains, as well as for emptying containers or water tanks, and draining water from dishwashers and washing machines.

2. Bayanin Tsaro

Always prioritize safety when operating electrical equipment, especially with water. Read and understand all instructions before installation and use.

3. Saita da Shigarwa

Shigar da famfon yadda ya kamata yana da matuƙar muhimmanci ga aikin famfon da kuma tsawon rayuwarsa.

3.1 Cire kaya da dubawa

Carefully remove the pump from its packaging. Inspect the pump for any signs of damage during transit. Ensure all components, including the 5-meter power cable and integrated float switch, are present.

Pedrollo TOP 2 Submersible Pump packaging and unit.

Pedrollo TOP 2 Submersible Pump packaging and unit.

3.2 Connecting the Discharge Hose

Attach a suitable discharge hose to the pump's outlet. Ensure the connection is secure to prevent leaks during operation. The pump is designed to accommodate standard hose sizes.

3.3 Positioning the Pump

Place the pump on a stable, flat surface in the area to be drained. Ensure the pump is fully submerged in the water before starting. The maximum immersion depth for the TOP 2 model is 3 meters.

Pedrollo TOP 2 Submersible Pump showing the integrated handle and float switch.

Pedrollo TOP 2 Submersible Pump showing the integrated handle and float switch.

3.4 Daidaita Canjin Tafiya

The pump features an integrated float switch for automatic start and stop. The float switch activates the pump when the water level rises and deactivates it when the water level drops to a certain point. Ensure the float switch can move freely without obstruction to function correctly.

4. Aiki

Once installed, operating the Pedrollo TOP 2 pump is straightforward.

4.1 Fara famfo

After ensuring the pump is correctly positioned and submerged, plug the power cable into a suitable electrical outlet. The integrated float switch will automatically start the pump when the water level reaches the activation point.

4.2 Aiki ta atomatik

The float switch will automatically turn the pump on and off based on the water level. This feature is ideal for continuous monitoring and draining of fluctuating water levels. The pump will continue to operate until the water level drops to the minimum emptying level of 14 mm from the bottom.

4.3 Tsaida Famfo

To manually stop the pump, simply unplug it from the power outlet. The pump will also stop automatically once the water level falls below the float switch's deactivation point.

5. Kulawa

Kulawa akai-akai yana tabbatar da ingantaccen aiki kuma yana tsawaita rayuwar famfon ku.

6. Shirya matsala

This section addresses common issues you might encounter with your Pedrollo TOP 2 pump.

MatsalaDalili mai yiwuwaMagani
famfo baya farawaBabu wutar lantarki
Float switch not activated
Motoci da yawa
Duba haɗin wutar lantarki da na'urar fashewa ta da'ira
Ensure water level is high enough to activate float
Allow motor to cool; check for obstructions
Low ko babu ruwa kwararaDischarge hose kinked or blocked
Pump intake blocked
Impeller damaged or clogged
Check and clear hose
Clean pump intake screen
Disconnect power and inspect/clean impeller
Pump yana ci gaba da gudanaFloat switch stuck in 'on' position
Ci gaba da shigar ruwa
Check float switch for obstructions
Verify the source of water inflow

Idan matsaloli sun ci gaba bayan ƙoƙarin waɗannan hanyoyin, tuntuɓi ƙwararrun ma'aikatan sabis.

7. Ƙayyadaddun bayanai

Technical details for the Pedrollo TOP 2 Submersible Pump.

Kusa view of the Pedrollo TOP 2 Submersible Pump, highlighting the technical label.

Kusa view of the Pedrollo TOP 2 Submersible Pump, highlighting the technical label.

8. Bidiyon Samfur na hukuma

No official product videos specifically for the Pedrollo TOP 2 submersible pump from a 'Seller' creator type were found in the provided data. The available video is for a different product (Truper submersible pump) and is therefore not included.

9. Garanti da Tallafawa

For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact Pedrollo customer service directly. Keep your purchase receipt as proof of purchase.

Takardu masu alaƙa - BABI NA 2

Preview Pedrollo TOP-FLOOR Submersible Drainage Pumps: Performance and Specifications
Explore the Pedrollo TOP-FLOOR series of submersible drainage pumps, designed for clear water applications. Learn about their performance range, application limits, construction details, and installation suitability for domestic emergencies.
Preview Pedrollo TOP MULTI-TECH Pumps Mai Saukarwa ta atomatik: Ƙayyadaddun bayanai & Ayyuka
Cikakken ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun ƙayyadaddun fasaha, masu lanƙwasa aikin aiki, jagorar shigarwa, da fasali don jerin Pedrollo TOP MULTI-TECH na Multi-stage ta atomatik famfo na submersible, tsara don tsaftace ruwa aikace-aikace.
Preview Pedrollo TOP MULTI-TECH & TOP MULTI-EVOTECH Automatic Submersible Water Pumps - Operation Manual
This document provides operational guidance for the Pedrollo TOP MULTI-TECH and TOP MULTI-EVOTECH automatic submersible multi-stage water pumps. It covers general information, operation, protections, and typical installation advice.
Preview Pedrollo TOP MULTI-TECH / TOP MULTI-EVOTECH Automatic Submersible Water Pump Operation Manual
This document provides operational instructions for the Pedrollo TOP MULTI-TECH and TOP MULTI-EVOTECH automatic submersible multi-stage water pumps. It covers general information, operating principles, installation advice, and protection features for optimal performance and longevity.
Preview Pompe Elettrosommergibili Pedrollo: DAVIS, 4-BLOCK, SALI, PRO 100AR - Istruzioni d'Uso
Guida completa alle pompe elettrosommergibili Pedrollo, inclusi i modelli DAVIS, 4-BLOCK, SALI, PRO 100AR, 3SR, 4SR, 4HR, 6SR, 6ST, 6HR, 4PD, 4PS, 6PD, 6PSR. Fornisce dettagli su installazione, uso sicuro, limiti operativi e manutenzione per un efficiente approvvigionamento idrico.
Preview Pompe Elettriche Pedrollo: Manuale d'Uso e Installazione Sicura
Guida completa alle istruzioni operative, di installazione e manutenzione per le pompe elettriche Pedrollo (modelli TOP, RX, D, DC). Offre informazioni essenziali per un uso sicuro ed efficiente.