The FCI GAMEWELL E3ID2-C is an inner door assembly designed for use within a 2-bay 'C' size command center. This component provides a structured mounting surface for various control and monitoring modules, ensuring a secure and organized installation within the fire safety system enclosure.

This image displays the FCI GAMEWELL E3ID2-C Inner Door Assembly, a black rectangular panel with multiple cutouts designed for mounting components within a 2-bay 'C' size command center. The panel features various mounting points around the edges of the cutouts and along its perimeter.
2. Bayanin Tsaro
- Always disconnect power to the command center before installing or servicing the inner door assembly.
- Ensure all connections are secure and properly terminated according to local electrical codes and manufacturer specifications.
- Ma'aikata masu ƙwarewa ne kawai zasu yi aikin shigarwa da gyara.
- Saka kayan kariya masu dacewa (PPE) yayin shigarwa.
- Refer to the main command center manual for additional safety guidelines.
3. Abubuwan Kunshin
Tabbatar da cewa duk abubuwan da aka gyara suna nan kuma basu lalace ba bayan kwashe kaya.
- 1 x FCI GAMEWELL E3ID2-C Inner Door Assembly
- Mounting hardware (if included with the assembly)
4. Saita da Shigarwa
Follow these steps to properly install the inner door assembly into your command center:
- Prepare the Command Center: Ensure the command center enclosure is securely mounted and all power is disconnected. Open the main door of the command center.
- Gano Ma'anonin Haɗawa: Locate the designated mounting points or rails within the 2-bay 'C' size command center where the inner door assembly will be installed.
- Position the Assembly: Carefully align the FCI GAMEWELL E3ID2-C inner door assembly with the mounting points inside the command center. The cutouts should face outwards, ready to receive modules.
- Tabbatar da Majalisar: Use the provided mounting hardware (screws, standoffs, etc.) to firmly attach the inner door assembly to the command center frame. Ensure it is level and stable. Do not overtighten.
- Sanya Moduloli: Once the inner door is secured, proceed to install the necessary control and monitoring modules into the designated cutouts on the assembly. Refer to the individual module's installation guide for specific instructions.
- Tabbatar da Shigarwa: Double-check all connections and ensure the inner door assembly and installed modules are secure before restoring power to the command center.
5. Aiki
The FCI GAMEWELL E3ID2-C inner door assembly is a passive component designed to house and organize active modules. Its primary function is to provide a stable and accessible platform for these modules within the command center. Operation of the overall system is dependent on the modules installed on this assembly.
- Access to the modules is gained by opening the main command center door.
- Ensure the inner door assembly remains securely fastened to prevent accidental dislodgement of installed modules.
6. Kulawa
Regular maintenance ensures the longevity and proper functioning of the inner door assembly and the modules it supports.
- Tsaftacewa: Periodically clean the surface of the inner door assembly with a soft, dry cloth. Avoid abrasive cleaners or solvents.
- Dubawa: Annually inspect the mounting hardware for tightness. Ensure there are no signs of corrosion or damage to the assembly.
- Module Check: While inspecting the inner door, also check the security of all modules mounted on it.
- Yanayin Muhalli: Ensure the command center environment remains within specified temperature and humidity ranges to prevent damage to the assembly and internal components.
7. Shirya matsala
As a passive component, the inner door assembly itself rarely experiences
Takardu masu alaƙa - FE3ID2C
![]() |
Gamewell Zans 200 Fire Alarm Control Unit - Data Sheet and Installation Guide Comprehensive data sheet and installation guide for the Gamewell Zans 200 Fire Alarm Control Unit, detailing features, specifications, system operation, accessories, and troubleshooting. |
![]() |
Gamewell Flex 405 Fire Alarm Control Panel: Installation & Operation Manual Comprehensive Installation & Operation Manual for the Gamewell Flex 405 Fire Alarm Control Panel (FACP) and Digital Alarm Communicator Transmitter (DACT). Covers features, installation, programming, operation, maintenance, and central station communication for fire safety professionals. |
![]() |
Gamewell IDENTIFLEX 632 Shigarwa da Manhajar Aiki Cikakken shigarwa da littafin aiki don Gamewell IDENTIFLEX 632 Analog/Adressable Fire Ƙararrawa Control Panel. Wannan jagorar ta ƙunshi bayanin tsarin, sassan, aiki, shirye-shirye, da gwaji. |
![]() |
Gamewell ZNS Wuta Sarrafa Ƙwararrun Ƙwararrun Ƙwararrun Ƙwararrun Wuta da Manhajar Aiki Wannan jagorar tana ba da cikakken shigarwa da umarnin aiki don Gamewell ZNS Microprocessor Based Conventional Al'ada Ƙararrawar Ƙararrawar Wuta. Yana rufe tsarin overview, shigarwa da wayoyi, katin gama gari da bayanan katin yanki, shirye-shirye, buƙatun wutar lantarki, da bayanan dacewa. |
![]() |
Gamewell ZNS Microprocessor Bassa na Al'ada na Ƙarfafa Ƙwararrun Ƙwararrun Ƙwararrun Wuta da Manhajar Aiki Wannan jagorar tana ba da cikakken shigarwa da umarnin aiki don Gamewell ZNS Microprocessor Based Conventional Al'ada Ƙararrawar Ƙararrawar Wuta. Ya ƙunshi cikakken bayani, shigarwa da wayoyi, cikakkun bayanan katin gama gari, ƙayyadaddun katin yanki, shirye-shiryen jumper, buƙatun wuta, da bayanan dacewa don ganowa da na'urorin sanarwa. |
![]() |
Gamewell Flex 4 & Flex 8 Fire Alarm Control Panels Installation and Operation Manual This manual provides comprehensive installation and operation instructions for the Gamewell Flex 4 and Flex 8 microprocessor-based fire alarm control panels. It covers system components, module settings, field wiring, system checkout, indicators, controls, operation, configuration, walk test procedures, compatible devices, module specifications, and power supply calculations. |