1. Gabatarwa
The UNI-T UT334-O2 is a portable single gas detector designed for the accurate detection of Oxygen (O2) levels. This device utilizes a free diffusion method and incorporates high-quality, sensitive sensors to ensure precise and repeatable measurements. Its robust design, featuring a high-strength engineering plastic shell, provides durability, water resistance, dust resistance, and explosion-proof capabilities, making it suitable for various industrial safety monitoring applications.
This manual provides essential information for the safe and effective use, setup, operation, and maintenance of your UT334-O2 gas detector. Please read it thoroughly before using the device.
2. Bayanin Tsaro
Koyaushe ku bi waɗannan jagororin tsaro don hana rauni ko lalacewar na'urar:
- Karanta duk umarnin: Familiarize yourself with the device's functions and safety precautions before operation.
- Use in specified environments: Operate the detector only within its specified temperature, humidity, and atmospheric pressure ranges.
- Regular calibration: Ensure the detector is calibrated regularly according to manufacturer recommendations to maintain accuracy.
- Avoid physical shock: Protect the device from drops or impacts, which can damage internal components.
- Kar a gyara: Never attempt to modify or disassemble the detector. This can compromise its safety features and void the warranty.
- Amintaccen baturi: Use only specified batteries. Do not mix old and new batteries or different types. Dispose of batteries properly.
- Explosion-proof certification: The device has explosion-proof certification. However, ensure it is used in accordance with local safety regulations for hazardous environments.
3. Samfurin Ya Ƙareview
Mabuɗin Siffofin
- Equipped with high-quality and sensitive sensors for accurate detection.
- High-definition color screen display for clear readings.
- Multiple alarm methods: sound, alarm light, and vibration.
- Curve graph periodic measurement display for trend analysis.
- Explosion-proof certification for use in hazardous environments.
Abubuwan da aka gyara
The package typically includes the UT334-O2 Gas Detector unit and necessary accessories for operation.

Image 1: UNI-T UT334-O2 Portable Single Gas Detector. This image shows the front view of the device, highlighting its compact size and display screen.
4. Saita
4.1 Shigar da Baturi
- Nemo murfin sashin baturi a bayan na'urar.
- Open the cover by sliding or unscrewing it as indicated.
- Saka batura da aka ƙayyade, don tabbatar da daidaiton polarity (+/-).
- Rufe murfin ɗakin baturi amintacce.
4.2 Kunna Wutar Farko
After battery installation, press and hold the power button (usually located on the front or side) for a few seconds until the display illuminates. The device will typically perform a self-test upon startup.
4.3 Calibration
For optimal accuracy, it is recommended to perform an initial calibration or verify the factory calibration. Refer to the detailed calibration procedure in the full technical manual or contact UNI-T support for specific instructions. Regular calibration is crucial for reliable gas detection.
5. Umarnin Aiki
5.1 Kunnawa / Kashewa
- Don Kunnawa: Press and hold the power button until the screen activates.
- Don Kashe: Press and hold the power button until a shutdown prompt appears, then confirm.
5.2 Fahimtar Nuni
The high-definition color screen displays real-time gas concentration, unit of measurement, battery status, and alarm indicators. Consult the device's on-screen menu or full manual for detailed explanations of all display icons and readings.
5.3 Gano Gas
Once powered on, the detector continuously monitors the ambient air for Oxygen (O2) levels. Position the detector in the area where gas detection is required. The sensor draws in air via free diffusion.
5.4 Ayyukan Ƙararrawa
The UT334-O2 is equipped with multiple alarm mechanisms:
- Aararrawa mai Sauti: A loud beeping sound indicates an alarm condition.
- Ƙararrawar gani: An alarm light (LED) will flash, typically red, to indicate an alarm.
- Ƙararrawar Jijjiga: The device will vibrate, providing a tactile alert.
Alarm thresholds are typically pre-set but may be adjustable via the device's menu. Refer to the full manual for details on setting alarm points.
5.5 Curve Graph Display
The device can display a curve graph of gas concentration over time, allowing users to monitor trends and identify fluctuations in O2 levels. Access this feature through the device's menu.
6. Kulawa
6.1 Tsaftacewa
Wipe the exterior of the detector with a soft, damp zane. Kada a yi amfani da masu tsaftace goge-goge ko masu narkewa, domin waɗannan na iya lalata casing or display. Ensure the sensor inlet is clear of dust and debris.
6.2 Sauya Sensor
Gas sensors have a limited lifespan. When the sensor reaches its end of life or becomes faulty, it will need replacement. This procedure should only be performed by qualified personnel using genuine UNI-T replacement sensors. Refer to the technical service manual for detailed instructions.
6.3 Sauya Baturi
Replace batteries when the low battery indicator appears on the display. Follow the battery installation steps outlined in Section 4.1.
6.4 Adana
Store the detector in a cool, dry place away from direct sunlight, extreme temperatures, and corrosive chemicals. Ensure batteries are removed if the device will be stored for an extended period.
7. Shirya matsala
If you encounter issues with your UT334-O2 detector, try the following common troubleshooting steps:
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| Na'urar baya kunnawa | Matattu ko shigar batura ba daidai ba | Sauya batura; tabbatar da daidaiton polarity. |
| Karatuttuka mara inganci | Sensor contamination or out of calibration | Clean sensor inlet; perform calibration. |
| No alarm when gas detected | Alarm settings incorrect; speaker/vibrator fault | Check alarm thresholds in settings; contact support if hardware fault suspected. |
| Nuni baya aiki | Battery issue; internal fault | Ensure batteries are charged/installed correctly. If problem persists, contact support. |
If these steps do not resolve the issue, please contact UNI-T customer support or your local distributor for further assistance.
8. Ƙayyadaddun bayanai
| Siffar | Ƙayyadaddun bayanai |
|---|---|
| Alamar | UNI-T |
| Samfura | UT334-O2 |
| Tushen wutar lantarki | Ana Karfin Batir |
| Girman samfur (D x W x H) | 1.89" x 2.67" x 5.5" (48mm x 68mm x 140mm kimanin) |
| Nauyin Abu | 1.6 Pounds (0.73 kg approx.) |
| Nau'in larararrawa | Audible, Visual (Light), Vibration |
| Hanyar Ganewa | Free Diffusion |
| Nunawa | High-definition color screen |
| Takaddun shaida | Explosion-proof certified |
9. Garanti da Tallafawa
For warranty information, please refer to the documentation provided with your purchase or contact the seller directly. UNI-T products typically come with a manufacturer's warranty covering defects in materials and workmanship.
For technical support, service, or inquiries regarding replacement parts, please contact UNI-T customer service or your authorized UNI-T distributor. Contact information can usually be found on the UNI-T official webshafin ko akan rasidin sayan ku.