1. Gabatarwa
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the TRU COMPONENTS Signal Pillar, model TC-12835336. This device is designed for industrial signaling applications, featuring red and green LED indicators with continuous or flashing light modes and an IP65 protection rating.
2. Bayanin Tsaro
- Karanta duk umarnin a hankali kafin shigarwa da aiki.
- ƙwararrun ma'aikata ne kawai su yi shigarwa.
- Tabbatar an katse wutar lantarki kafin a yi duk wani shigarwa, gyarawa, ko gyara matsala.
- Tabbatar da daidai voltage (24V) is supplied to prevent damage to the unit.
- Do not expose the device to conditions beyond its specified IP65 rating.
- A guji fallasa kai tsaye ga hasken LED na tsawon lokaci.
3. Samfurin Ya Ƙareview
The TRU COMPONENTS Signal Pillar TC-12835336 is a robust signaling device with two LED segments (red and green) for clear visual indication in various industrial environments.

Hoto na 1: TRU COMPONENTS Signal Pillar TC-12835336. This image displays the signal pillar with its black base, threaded mounting shaft, and two translucent LED segments: red on top and green below. A bundle of multi-colored wires extends from the base for electrical connection.
Abubuwan:
- Abubuwan LED: Red and Green, providing visual status.
- Gidaje: Durable black housing with a diameter of 55 mm.
- Zaren Tsayawa: Don shigarwa mai aminci.
- Wayoyi kayan doki: Multi-colored wires for power and control connections.
4. Ƙayyadaddun bayanai
| Siffar | Daki-daki |
|---|---|
| Lambar Samfura | TC-12835336 |
| Launuka masu haske | Ja, Kore |
| Hanyoyin Haske | Continuous or Flashing |
| Diamita | Ø 55 mm |
| Ƙimar Kariya | IP65 |
| Voltage | 24V |
| Mai ƙira | GASKIYA BAYANI |
| Ƙasar Asalin | China |
5. Saita da Shigarwa
- Kashe Haɗin Wuta: Ensure all power to the installation area is disconnected before beginning.
- hawa: Securely mount the signal pillar using its threaded base. Ensure the mounting surface is stable and capable of supporting the device.
- Waya: Connect the signal pillar's wires to the appropriate 24V power supply and control system. Refer to the wiring diagram (if provided separately with the product) for specific connections for continuous or flashing modes. Typically, different wires control each LED segment and the flashing function.
- Environmental Seal: Ensure the IP65 rating is maintained after installation by properly sealing all connections and mounting points, especially in environments where dust or water ingress is a concern.
- Haɗin Wuta: Once all connections are secure and verified, restore power to the system.
6. Umarnin Aiki
The TRU COMPONENTS Signal Pillar operates by receiving a 24V signal to illuminate its LED segments. The specific wiring configuration determines whether a segment illuminates continuously or flashes.
- Ci gaba da Haske: Apply 24V to the designated wire for the desired LED segment (e.g., red or green) to achieve continuous illumination.
- Hasken walƙiya: If wired for flashing operation, applying 24V to the corresponding wire will activate the flashing mode for that LED segment. Consult your system's wiring diagram for specific control signals.
- Multiple Segments: Both red and green segments can be activated independently or simultaneously, depending on the control system's design.
7. Kulawa
The TRU COMPONENTS Signal Pillar is designed for low maintenance. Regular checks can ensure optimal performance.
- Tsaftacewa: Periodically clean the exterior of the signal pillar with a soft, damp zane. Kada a yi amfani da masu tsabtace abrasive ko sauran ƙarfi.
- Dubawa: Regularly inspect the housing and wiring for any signs of damage, wear, or loose connections.
- Hatimin Mutunci: For IP65 rated protection, ensure all seals and cable glands remain intact and properly tightened.
- Kashe Haɗin Wuta: Koyaushe cire haɗin wuta kafin aiwatar da kowane kulawa.
8. Shirya matsala
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| Signal pillar does not illuminate. | No power supply; incorrect wiring; faulty LED segment. | Check 24V power supply; verify wiring connections against diagram; if power and wiring are correct, the LED segment may require replacement. |
| LED segment illuminates continuously instead of flashing (or vice-versa). | Incorrect wiring for flashing/continuous mode. | Review wiring diagram and ensure correct connections for the desired operating mode. |
| Aiki na wucin gadi. | Haɗin wayoyi marasa ƙarfi; samar da wutar lantarki mara ƙarfi. | Inspect all wiring connections for tightness; check power supply stability. |
Idan matakan magance matsalar basu warware matsalar ba, tuntuɓi goyan bayan abokin ciniki ko ƙwararren masani.
9. Garanti da Tallafawa
For information regarding warranty coverage, technical support, or replacement parts, please refer to the documentation provided with your purchase or contact TRU COMPONENTS customer service. Keep your purchase receipt as proof of purchase.
Manufacturer: TRU COMPONENTS