RAB Lighting B17

Jagorar Umarnin Hasken Rab B17 LED Bollard Lighting

Saukewa: B17

1. Gabatarwa

This manual provides detailed instructions for the installation, operation, and maintenance of the RAB Lighting B17 LED Bollard Light. This outdoor luminaire features field-adjustable wattage and selectable color temperature (CCT), designed for various outdoor applications.

Babban fasali sun haɗa da:

RAB Lighting B17 LED Bollard Light

Figure 1: RAB Lighting B17 LED Bollard Light (Model B17D shown).

2. Bayanin Tsaro

GARGADI: Risk of electric shock. Disconnect power before installation or servicing. Installation should be performed by a qualified electrician in accordance with all applicable national and local electrical codes.

3. Abubuwan Kunshin

Tabbatar cewa duk abubuwan da aka gyara suna nan kafin fara shigarwa:

4. Saita da Shigarwa

Follow these steps for proper installation of the B17 LED Bollard Light:

  1. Shirya Wurin Shigarwa: Ensure the mounting surface is stable and level. Run electrical conduit and wiring to the desired location according to local codes.
  2. Cire haɗin Wuta: Turn off power at the circuit breaker before starting any electrical work.
  3. Mount the Bollard: Secure the bollard base to the mounting surface using appropriate hardware. Ensure a watertight seal if required by local codes.
  4. Yi Haɗin Wutar Lantarki: Connect the fixture's wires to the supply wires. Follow standard wiring practices:
    • Black to Line (L)
    • White to Neutral (N)
    • Green/Ground to Ground (G)
    • Purple to Dimming (+) (for 0-10V dimming)
    • Gray to Dimming (-) (for 0-10V dimming)
    Tabbatar cewa duk haɗin gwiwa amintattu ne kuma an killace su.
  5. Zaɓi Wattage da CCT: Before closing the fixture, adjust the wattage and CCT switches located inside the fixture head. Refer to Section 5 for details.
  6. Secure the Fixture Head: Attach the fixture head to the bollard body, ensuring all seals are properly seated to maintain the wet location rating.
  7. Dawo da Power: Turn on power at the circuit breaker and test the light.
UL Listed and Wet Location Rated symbols

Figure 2: The B17 Bollard Light is UL Listed and rated for wet locations, ensuring durability in outdoor environments.

5. Umarnin Aiki

5.1. Field-Adjustable Wattage

The B17 bollard light allows you to select the desired wattage output to optimize brightness and energy consumption. A switch located inside the fixture head enables selection between 24W, 19W, and 14W.

Don daidaitawa: Disconnect power. Open the fixture head. Locate the wattage selection switch and move it to the desired setting. Close the fixture head and restore power.

5.2. Selectable Color Temperature (CCT)

The fixture offers three color temperature options to suit different aesthetic preferences and applications. A separate switch inside the fixture head allows selection between 3000K, 4000K, and 5000K.

Don daidaitawa: Disconnect power. Open the fixture head. Locate the CCT selection switch and move it to the desired setting. Close the fixture head and restore power.

Image showing 14W, 19W, 24W wattage options and 3000K, 4000K, 5000K CCT options for the bollard light

Figure 3: Visual representation of adjustable wattage and selectable CCT settings.

5.3. 0-10V Dimming

The B17 bollard light is compatible with 0-10V dimming systems. Connect the purple and gray dimming wires to a compatible 0-10V dimmer control. This allows for smooth adjustment of light output from 100% down to 10% (or lower, depending on dimmer specifications).

Ensure the dimmer is rated for LED loads and is compatible with 0-10V dimming protocols.

6. Kulawa

The B17 LED Bollard Light is designed for minimal maintenance due to its long LED lifespan of 50,000 hours.

Image indicating a 50,000-hour lifespan for the LED bollard light

Figure 4: The B17 LED Bollard Light offers a long 50,000-hour operational lifespan.

7. Shirya matsala

MatsalaDalili mai yiwuwaMagani
Haske baya kunnawaBabu wutar lantarki.
Sako da wayoyi.
Wat ba daidai batage/CCT setting.
Check circuit breaker. Ensure power is on.
Verify all wire connections are secure (power off first).
Tabbatar da wattage/CCT switches are set correctly.
Haske yana kyalli ko ya dushe ba zato ba tsammani.Dimmer mara jituwa.
Loose dimming wire connection.
Voltage canje -canje.
Ensure 0-10V dimmer is compatible with LED loads.
Check purple and gray dimming wire connections.
Tuntuɓi ma'aikacin wutar lantarki don duba daidaiton wutar lantarki.
Fitowar haske ya yi ƙasa da ƙarfi.Wat ba daidai batage saitin.Daidaita wattage selection switch inside the fixture head (power off first).
Light color is not desired.Tsarin CCT mara daidai.Adjust the CCT selection switch inside the fixture head (power off first).

8. Ƙayyadaddun bayanai

SiffarDaki-daki
Sunan SamfuraB17
AlamarFarashin RAB
WatatageField-Adjustable: 24W / 19W / 14W
Zazzabi Launi (CCT)Selectable: 3000K / 4000K / 5000K
Dimming0-10V Dimmable
Tsawon rayuwa50,000 hours
Kayan abuMetal body, Glass shade
Ƙimar MuhalliUL Listed for Wet Locations
Abubuwan da aka haɗaKunna-Kashewa
UPC192552028424
ASINB0DY2FPPNS

9. Garanti da Tallafawa

For warranty information and technical support, please contact RAB Lighting directly. Refer to the official RAB Lighting website or your purchase documentation for specific warranty terms and contact details.

RAB Lighting Contact: www.rablighting.com