1. Gabatarwa
The JOY-IT JT-OMS01 is a versatile 3-in-1 portable device combining a dual-channel oscilloscope, a precise multimeter, and a versatile signal generator. Designed for flexibility in measurement and signal generation, it is suitable for both desktop use and on-the-go applications. Its robust casing and integrated stand ensure stability. The bright 7.11 cm (2.8") display provides clear measurement waveforms, which can be saved as screenshots.
Babban fasali sun haɗa da:
- Compact 3-in-1 device: Oscilloscope, Multimeter, Signal Generator.
- Bright 7.11 cm (2.8") display for clear measurement waveforms.
- Dual-channel oscilloscope with 50 MHz bandwidth.
- Rechargeable lithium battery via USB-C.
- Robust casing with integrated stand.
2. Samfurin Ya Ƙareview
The JT-OMS01 integrates multiple functionalities into a single portable unit. Below is an image illustrating the device's front panel and key components.

Hoto na 2.1: Gaba view of the JOY-IT JT-OMS01. This image displays the device's screen showing oscilloscope waveforms, control buttons for navigation and function selection (e.g., MOVE, CURSOR, TRIGGER, PRM, CH1, CH2, AUTO, SAVE, MENU), the power button, and input jacks for 10A, mA, COM, and VΩ-Hz measurements. The device also features an integrated stand visible from the side.
2.1. Gudanarwa da Haɗawa
- Nunawa: 7.11 cm (2.8") screen for waveform display and measurement readings.
- Maɓallan kewayawa: Up, Down, Left, Right, and Center (Play/Pause) buttons for menu navigation and parameter adjustment.
- Maɓallan Ayyuka: CH1, CH2, AUTO, SAVE, MENU, MOVE, CURSOR, TRIGGER, PRM.
- Maɓallin Wuta: Located on the lower left, used to turn the device on/off.
- Shigar Jacks:
- 10 A: Input for high current measurements (max 10A, fused 250V MAX).
- mA: Shigar da milliampere measurements (max 1A, fused 250V MAX).
- COM: Common ground input for all measurements.
- VΩ-Hz: Shigarwa don voltage, resistance, frequency, diode, and continuity measurements (600V CAT IV, 1000V CAT III).
- Kebul na USB-C: For charging the internal lithium battery and data transfer (located on the side, not visible in this image).
3. Saita
- Cire kaya: Carefully remove the device and all accessories from the packaging. Verify that all components listed in the packing list are present.
- Na farko Cajin: Before first use, fully charge the device's internal lithium battery using the provided USB-C cable and a compatible 5V/1A or 5V/2A USB power adapter. The charging indicator will show the charging status.
- Kunnawa/Kashewa: Press and hold the red power button (⑂) located on the front panel to turn the device on or off.
- Language Selection (if applicable): Upon first power-on, you may be prompted to select a language. Use the navigation buttons to select English and confirm.
- Gwajin Kai: The device may perform a brief self-test upon startup. Wait for it to complete before proceeding.
4. Umarnin Aiki
4.1. Oscilloscope Mode
The oscilloscope function allows for the visualization and analysis of electrical signals over time.
- Entering Oscilloscope Mode: The device typically defaults to oscilloscope mode upon startup. If not, navigate to it via the MENU button.
- Binciken Haɗawa: Connect the oscilloscope probes to the CH1 and/or CH2 BNC connectors. Connect the ground clip of the probe to the circuit's ground.
- Adjusting Vertical Scale (Volts/Div): Use the navigation buttons to adjust the vertical sensitivity (V/div) for each channel (CH1, CH2) to fit the signal on the screen.
- Adjusting Horizontal Scale (Time/Div): Adjust the horizontal time base (s/div) to view the desired number of signal cycles.
- Tarawa:
- Danna maɓallin FADAKARWA button to access trigger settings.
- Select trigger mode (Auto, Normal, Single) and trigger type (rising edge, falling edge).
- Adjust the trigger level to stabilize the waveform.
- Auto-Set: Danna maɓallin AUTO button for automatic scaling and triggering of the input signal.
- Ma'auni: Yi amfani da PRM (Parameter) button to display automatic measurements (e.g., Vpp, Vrms, Frequency).
- Saving Waveforms: Danna maɓallin ACE button to capture the current waveform as a screenshot.
4.2. Multimeter Mode
The multimeter function allows for precise measurement of various electrical parameters.
- Entering Multimeter Mode: Navigate to multimeter mode via the MENU button.
- Haɗa Jagororin Gwaji:
- Za voltage, resistance, frequency, diode, and continuity: Connect the red lead to the VΩ-Hz jack and the black lead to the COM jak.
- For current (mA): Connect the red lead to the mA jack and the black lead to the COM jak.
- For high current (10A): Connect the red lead to the 10 A jack and the black lead to the COM jak.
- Zaɓan Aikin Aunawa: Use the navigation buttons to select the desired measurement function (e.g., DC Voltage, AC Voltage, Resistance, Capacitance, Diode Test, Continuity Test, Temperature).
- Ɗaukar Ma'auni: Apply the test leads to the circuit or component under test. The measurement will be displayed on the screen.
4.3. Signal Generator Mode
The signal generator function allows for the output of various waveforms for testing purposes.
- Entering Signal Generator Mode: Navigate to signal generator mode via the MENU button.
- Haɗa Fitarwa: Connect a test lead from the signal generator output (often shared with a multimeter input, refer to specific port markings on the device) to the circuit requiring the signal.
- Selecting Waveform: Choose the desired waveform type (e.g., Sine, Square, Triangle, Pulse, Arbitrary) using the navigation buttons.
- Daidaita Ma'auni: Saita mitar, amplitude, and offset of the generated signal as required.
- Outputting Signal: Activate the signal output.
5. Kulawa
- Tsaftacewa: Tsaftace na'urar tare da laushi, bushe bushe. Kada a yi amfani da masu tsabtace abrasive ko kaushi.
- Ajiya: Ajiye na'urar a wuri mai sanyi, busasshiyar nesa da hasken rana kai tsaye da matsanancin zafi.
- Kulawar Baturi: To prolong battery life, avoid fully discharging the battery frequently. Recharge it regularly, especially if storing for extended periods.
- Kulawar Bincike: Inspect probes and test leads regularly for damage. Replace if insulation is cracked or wires are exposed.
6. Shirya matsala
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| Na'urar baya kunnawa. | Ana cire baturi. | Connect the device to a USB-C charger and allow it to charge for at least 30 minutes before attempting to power on again. |
| No waveform displayed in oscilloscope mode. | Probe not connected correctly; signal too small or too large; incorrect trigger settings. | Ensure probes are securely connected. Use the AUTO button. Adjust V/div and Time/div settings. Check trigger level and mode. |
| Multimeter readings are inaccurate. | Incorrect function selected; poor test lead connection; discharged battery. | Verify the correct measurement function is selected. Ensure test leads are firmly connected. Recharge the battery. |
| Na'urar ta daskare ko zama mara amsawa. | Kuskuren software na wucin gadi. | Perform a soft reset by holding the power button until the device turns off, then power on again. If persistent, contact support. |
7. Ƙayyadaddun bayanai
| Siffar | Daki-daki |
|---|---|
| Nunawa | 7.11 cm (2.8"), 320 x 240 pixels |
| Haɗin kai | USB-C |
| Tushen wutan lantarki | Lithium battery, 3000 mAh (rechargeable via USB-C, 5V / 1A) |
| Nauyi | 349g ku |
| Girma (L x W x H) | 167 x 89 x 35 mm |
| Oscilloscope Specifications: | |
| Tashoshi | 2 |
| Sampda Rate | 250 MSA/s |
| Bandwidth | 50 MHz (both channels) |
| Impedance | 1 MΩ |
| Zurfin Ma'aji | 1k ku |
| Vertical Sensitivity (Y-Divider) | 10 mV/div - 10 V/div (X1) |
| Horizontal Scale (X-Divider) | 10 ns - 20 s |
| Max. Shigar da Voltage | 400 V |
| Haɗa Input | DC, AC |
| Hanyoyi masu tayar da hankali | Automatic, Normal, Single |
| Nau'in Tasiri | Tashi gefen, Faɗuwa gefen |
| Ayyukan Lissafi | 8 basic operations, FFT |
| Multimeter Specifications: | |
| Ma'auni Range | (Details from description: DC/AC measurements, resistance, capacitance, temperature detection, diode measurement, continuity test) |
| Signal Generator Specifications: | |
| Waveforms | Almost all common waveforms (Sine, Square, Triangle, Pulse, Arbitrary) |
8. Garanti da Tallafawa
8.1. Garanti Bayani
Information regarding the specific warranty period and terms for the JOY-IT JT-OMS01 is not provided in the product description. Please refer to the warranty card included with your product or contact JOY-IT customer service for detailed warranty information.
8.2. Tallafin Abokin Ciniki
For technical assistance, troubleshooting, or service inquiries, please contact JOY-IT customer support. Contact details are typically available on the manufacturer's official webshafin ko a cikin marufi na samfur.
Please have your model number (JT-OMS01) and purchase information ready when contacting support.