Delta PLC Modbus RTU Connection
Manual mai amfani
Farashin 2302EN
V1.0.0
da Delta PLC
Modbus RTU Connection
Manual aiki
Jerin Kanfigareshan Tsarin Module I/O mai nisa
| Bangaren No. | Ƙayyadaddun bayanai | Bayani |
| GFMS-RM01S | Jagora Modbus RTU, 1 Port | Babban Mai Gudanarwa |
| GFDI-RM01N | Digital Input 16 Channel | Input dijital |
| GFDO-RM01N | Fitar Dijital 16 Channel / 0.5A | Fitowar Dijital |
| Farashin 0202 | Ƙarfin wutar lantarki 24V / 48W | Tushen wutan lantarki |
| Farashin 0303 | Ƙarfin wutar lantarki 5V / 20W | Tushen wutan lantarki |
| 0170-0101 | 8 fil RJ45 mai haɗin mace/RS-485 Interface | Module na Interface |
1.1 Bayanin samfur
I. Ana amfani da tsarin dubawa a waje don canza tashar sadarwa ta Delta PLC RS485 (Modbus RTU) zuwa mai haɗin RJ45
II. Babban mai sarrafawa yana kula da gudanarwa da kuma daidaitawa na sigogi na I / O da sauransu.
III. Tsarin wutar lantarki da tsarin dubawa daidai ne don I/Os mai nisa kuma masu amfani za su iya zaɓar samfurin ko alamar da suka fi so.
Delta PLC Connection Setup
Wannan babin yana bayanin yadda ake amfani da shirin ISPSoft don haɗa Delta PLC da
.
Don cikakkun bayanai, da fatan za a koma zuwa ISPSoft Manual User
2.1 Delta PLC Haɗin Hardware
I. Tashar tashar haɗin kai tana ƙasan injin. Yin amfani da DVP-14SS2 don nunawa, haɗa Port 2(RS485 A/B) zuwa tsarin dubawa (1/2) don canza shi zuwa haɗin RJ45, wanda za'a haɗa shi zuwa babban mai sarrafawa.
2.2 Saitin Haɗin Haɗin Delta PLC
I. Kaddamar da ISPSoft kuma saita saitunan sadarwa na COM2 zuwa yanayin RTU, 115200bps, 8 data bits, Babu daidaici da 1 tasha bits (115200, 8,N, 1). Shirye-shiryen Exampda:
※ Dole ne saitin siginar sadarwa ya kasance daidai da
don ba da damar sadarwa
II. Yi amfani da umarnin MODRW don saita karatun/rubutun
I/O module
S1: Adireshin na'urar da aka haɗa: K1 ~ K254
S2: Lambar aikin sadarwa
S3: Adireshin da za a karanta/ rubuta bayanai
S: Rijista inda aka yayyage bayanan da za a karanta/rubutu
N: Tsawon bayanan da za a karanta/rubutu
※
GFDI-RM01N na farko yana da adireshin rajista a 1000(HEX)
※
GFDO-RM01N na farko yana da adireshin rajista a 2000(HEX)
※ Lura: Lokacin amfani da umarnin karantawa, da fatan za a yi amfani da rajistar D1296 don fara amfani da bayanan da aka adana
Yi amfani da umarnin "karanta" da ke sama don saita D200 don karanta rajista 2 tare da farkon DI azaman tsohonample.
| Yi rijista | DATA | Bayani | |
| D200 (ƙarashin odar byte) | "0" | Farashin 1 ADR | |
| D200 (Highoder byte) | |||
| D201 (ƙarashin odar byte) | CM D3 C MD 0 |
||
| D201 (Babban tsari) | "3" | ||
| D202 (ƙarashin odar byte) | 44044 | Data Bytes | |
| D202 (Babban tsari) | "2" | ||
| D203 (ƙarashin odar byte) | 44044 | Abun ciki a adireshin 2100 I-1 | PLC za ta canza ASCII ta atomatik Haruffa cikin ƙima kuma adana su a D1296=H0001 |
| D203 ku | 4,019 | ||
| D204 ku | 44044 | ||
| D204 ku | 4414, | ||
| D205 ku | 440,4 | Abun ciki a adireshin 2101 1-1 | PLC za ta canza ASCII ta atomatik haruffa cikin ƙima kuma adana su a D1297=1-10000 |
| D205 ku | 44044 | ||
| D206 ku | 4404, | ||
| D206 ku | 440,4 | ||
| D207 ku | Farashin CHK1 | ||
| D207 ku | Farashin CHK0 | ||
Dangane da wannan tebur, masu amfani za su iya amfani da rajistar D1296 don karanta dukkan bayanan (Kalma).
III. rogramming Exampda:
Wannan example shine don sadarwa da amfani da sadarwar RS485 don karantawa/rubutu
module


Takardu / Albarkatu
![]() |
DAUDIN Delta PLC Modbus RTU Connection [pdf] Manual mai amfani Delta PLC Modbus RTU Connection, Delta PLC, Modbus RTU Connection, RTU Connection, Connection |