DuraTherm Digital Dumama Element Control Manual

DuraTherm Digital Heating Element Controller Instruction Manual

DuraTherm Digital Dumama Element Control Manual
DuraTherm Digital Heating Element Controller

MALAMAN BANGON LANTARKI

Da fatan za a karanta umarnin sosai kafin yunƙurin sa samfurin ko haɗa shi zuwa tsarin wutar lantarki.

Da fatan za a tabbatar cewa kun zaɓi nau'in wutar lantarki mai dacewa don dumama tawul ɗinku.

Kariyar Tsaro: Wannan samfur ya kamata a ayyana shi ta wurin ƙwararren mutum wanda zai iya tabbatar da yarda da IEE. Sashe na P da dokokin ƙananan hukumomi. Tabbatar cewa da'irar wutar lantarki na mains da naúrar spur da aka haɗa duka biyun sun keɓanta kafin tarar. Wannan rukunin bai kamata ya sanya shi a cikin IEE bathroom Zone.1.

UMARNI NA WIRING
Ana buƙatar fused spur a cikin da'irar wadata zuwa mai sarrafawa. dace da daidai girman fiusi.
Ana haɗe tashoshi 2 x E & 2 x N akan allon da'ira da aka buga.

WAyoyin ELECTRICAL ELEMENT WIRES (FITA)
Electrical Element Wires
Daga Hagu zuwa Dama tashoshi 1-3 yayi daidai da kebul na Element
Ya kamata a haɗa wayoyi masu mahimmanci kamar haka:
Green/Yellow Duniya
to terminal 1 (N on board)
Blue Neutral to terminal 2 (L on board)
Brown Rayuwa to terminal 3 (L/T on board)
MUHIMMANCI- Wannan rukunin dole ne a yi ƙasa
MANYAN WIRES (IN)
Main Cable Wires
From Left to Right terminals 4-6 correspond to the Mains cable wires
Ya kamata a haɗa manyan wayoyi kamar haka:
Brown Rayuwa
to terminal 4 (L on board)
Blue Neutral to terminal 5 (N on board)
Green/Yellow Duniya to terminal 6 (E on board)
VERY IMPORIANT – Wannan rukunin dole ne a yi ƙasa
Main Cable Wires Clamp kebul na element zuwa kasan mai kula da bango
Clamp Element Cable Bottom
A hankali shigar da farantin sarrafawa a cikin akwatin baya don tabbatar da cewa babu wayoyi da ke cikin tarko yayin aikin zama. Yi amfani da madaidaitan sukurori biyu don tabbatar da akwatin baya. Control Plate Wires Trapped

HUKUNCIN AIKI

There are four buttons on the control plate. ON/OFF (1), temperature Increase (2), rage zafin jiki (3), ECO boost button (4).

AIKI GASKIYA

The unit in standby has the main LED in JAN. To turn on in normal mode, press the KASHE/KASHE button kuma
release it. The LED zai juya BLUE, da ORANGE LED bank will light between one to five LED's.

To increase or decrease the temperature press the ‘increase/decrease’ buttons to attain the desired setting. Each one of the ORANGE LEDs represents the following power output from the element:
5 LEDs =100% power > 4 LEDs = 85% power > 3 LEDs = 70% power > 2 LEDs = 55% power >1 LED = 40% power
Don juya naúrar KASHE danna KASHE/KASHE button da sake shi.
NB The control plate contains a memory and whatever the temperature that was set when the unit was turned KASHE, will be the temperature (number of LED’s lit) that the element will resume at when the unit is turned ON a karo na gaba.

Ayyukan ECO

Press the ECU button from either power on or from standard control. the power LED will turn GREEN. The
ECO function allows you to go to a higher power setting for 30 minutes (To heat the towel warmer) this power level can be set in the first 30 minutes. After 30 minutes the power is reduced to the pre-set lower level for 90 minutes. The power output can be set using the increase/ decrease buttons to set your preferred rail temperature. After 2 Hours the controller will turn on.
Both the 30 minute and the 90 minutes settings are saved in the controller.

5 LEDs = 100% power > 4 LEDs = 85% power > 3 LEDs = 70% power > 2 LEDs = 55% power >1 LED = 40% iko

Bayanan Fasaha.
Kariyar shiga: IPX4
Voltage: Saukewa: 230-245
Mafi girman fitarwar wuta: 800w
Girma: 85 x 85 x 20mm
Amincewa: CE, tested to EN55014-1:2006

Takardu / Albarkatu

PDF thumbnailMai Kula da Abubuwan Dumama na Dijital
Instruction Manual · Digital Heating Element Controller, Heating Element Controller, Element Controller, Controller

Magana

Yi Tambaya

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Yi Tambaya

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.