Elitech-logo

Elitech Glog 5 Real Time Single Use IoT Data Logger

Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-product

Gabatarwar samfur

Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-1

  1. Back mounted hanging hole
  2. LCD nuni allon
  3. LED nuna haske
  4. Start stop button
  5. Serial number
  6. Hasken firikwensin
  7. Power supply+data interface
  8. Gina na'urori masu auna firikwensin
  9. Activate/Flight Mode Button
  10. firikwensin waje

LCD nuni

Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-2

  1. Matsayin aiki
  2. Bayanin Aiki
  3. Yanayin ƙaura
  4. Matsayin sigina
  5. Matsayin baturi
  6. Alamar ƙararrawa ta haske da girgiza
  7. Time and number of records
  8. Temperature and humidity values

Lura: To ensure data reliability, please do not enable recording when the battery level is less than or equal to 20% ( Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-3 between 10% and 20%)

Tebur na zaɓi

(daidaitaccen haske da firikwensin girgiza)

 

Samfura Nau'in bincike Ma'auni kewayon Daidaito
 

Farashin 5T

 

Built in temperature

 

-30 ℃ ~ 70 ℃

 

± 0.5 ℃

 

Farashin 5TH

 

Built in temperature and humidity

-30℃~70℃ 0%RH~100%RH ± 0.5 ℃

± 5% RH

 

Farashin 5TE

External temperature+internal temperature  

-40 ℃ ~ 85 ℃

 

± 0.5 ℃

 

Glog 5 THE

 

External temperature and humidity+internal temperature

External: -40℃~85℃ 0%RH~100%RH

built-in: -30℃~70℃

± 0.5 ℃

± 5% RH

 

Farashin 5TLE

External ultra-low temperature+internal temperature External: -200℃~150℃ built-in: -30℃~70℃ ±0.5℃(-40℃~85℃)

±1℃(-100℃~150℃)

± 2 ℃ (other)

Glog 5 CO₂ External ul-CO₂ & temperature

& humidity built-in temperature

-30℃~70℃ 0%RH~100%RH

0%~100vol%

± 0.5 ℃

± 5% RH

1vol%+3vol% measured

Sigar fasaha

Kewayon girgiza 0-16 g
Range of illumination intensity 0 ~ 52000 Lux
Magance iko 0.1°C/0.1%RH/0.1g/1Lux
Maɓalli Ƙirar maɓalli biyu
Hasken nuni Ja da kore, ja da shuɗi LED fitilun nuni
Nunawa Broken code display screen
Hanyar sanyawa LBS+GPS (optional)
Ƙarfin ajiya 60000 (pre shadow data) 32000 (normal recording+rear shadow data)
Bayanan inuwa Gaban+Baya
Tazarar rikodin 1min~24h; Default: 5 minutes
Tazarar lodawa 1min~24h adjustable Default: 60 minutes
Hanyar loda bayanai 4G+2G
Freight initiation method Button, platform, timer
Freight stopping method Button, platform, full memory
Repeat startup 3 times (within the shelf life)
Yanayin Jirgin sama Button, timer, electronic fence
Yanayin ƙararrawa Overlimit and low battery
Nau'in baturi 3.0V disposable lithium manganese battery 4800mAh (CR14505 3B6H)
Haɓaka OTA Upgrades can be made through data management software and platforms
Matsayin hana ruwa IP65 (gina)
Yanayin aiki -30 ℃~70℃, 0% RH~100% RH (non condensing)
Yanayin ajiya 15~30℃,20~75%RH
Ƙayyadewa da girma 103 x 61.3 x 30 (mm)
Rayuwar baturi Record once every 5 minutes in a 25 ℃ environment, upload every 30 minutes, and use the temperature and humidity recorder for a total of 60 days;
Rayuwar rayuwa (Usage time+Storage time) 1 year

Sigar fasaha

Ƙara na'ura
Dandalin shiga website: http://www.i-elitech.com, or scan the code to download and install the APP . Register, log in, and add devices according to the prompts.Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-4

Kunnawa

Latsa ka riƙe Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-5 button for 5s, and the screen will display normally, indicating that the device has been activated.Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-6

Lura: Clicking on the button and the screen displaying normally indicates that the device has been activated;

Fara Rikodi
Latsa ka riƙe Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-7 button for 5s, and the screen will display a Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-8 symbol, indicating successful startup recording; If theElitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-8indicator flashes, it will enter a delayed countdown state, and after the delay ends, it will automatically start recording;Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-9

Dakatar da rikodi

Latsa ka riƙe Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-7 button for 5s, and the screen will display a Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-10 sign indicating that the recording has been successfully stopped;Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-11

fitarwa bayanai

The device is connected to the computer USB interface through a data cable and will automatically generate PDF+CSV format data reports. You can copy the generated report to your computer for saving.Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-12

Lura: The keys are invalid during the data export process

Yanayin Jirgin sama

  • Kunna: Latsa ka riƙe Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-5 button for 5s, and the screen will display a Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-13symbol indicating that the airplane mode has been successfully activated;
  • Rufe: Latsa ka riƙe Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-5button for 5s. If the screen Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-13icon disappears, it indicates that the airplane mode has been turned off;

Lura: To enable and disable other flight modes, please operate through the platform or app.Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-14

Freight Management Operation Instructions

  1. After logging into the platform or app, click on the ‘Freight Management’ menu in the main menu;
  2. Click on the ‘Configuration’ menu on the homepage, and sequentially create and add ‘User Management’, ‘Carrier’, ‘Location’, ‘Alarm Presets’, and’ Freight Template ‘;
  3. Click on the ‘Freight Management’ menu on the homepage to create and manage freight;

Lura: For detailed operation manuals, please refer to the operating instructions on the platform or APP;

Bayanin haske mai nuna alama

Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-15

Umurnin nunin LCD

Elitech-Glog-5-Real-Time-Single-Use-IoT-Data-Logger-fig-16

Umurni na kariya da kiyayewa

Umarnin aminci

  • Don tabbatar da cewa kun shigar da amfani da wannan samfurin daidai, da fatan za a karanta kuma ku bi ƙa'idodi masu zuwa:

Baturi

  • Please use the original battery and do not use other batteries to prevent damage to the equipment or other malfunctions. Do not disassemble, squeeze, hit, or heat the battery privately, and do not place it in a fire, otherwise it may cause battery explosion and fire.

Kayan aiki

  • Do not use this equipment in flammable and explosive gas environments, otherwise it may cause explosions or fires. During the use of the equipment, if the equipment emits a burnt or other odor, the power supply should be immediately cut off and the manufacturer or supplier should be contacted in a timely manner.

Precautions and maintenance requirements

  • If the equipment is not used for a long time, it should be removed and stored in a dry and cool environment in the packaging box.
  • Users are not allowed to make any unauthorized changes to this device. Any unauthorized changes may affect the accuracy of the device or even damage it.
  • Do not place the device outdoors for use to avoid instrument short circuits, burns, and other malfunctions caused by adverse weather conditions such as rain and lightning.
  • When the recorder is offline (no data upload), please confirm the networking status of the device;
  • Da fatan za a yi amfani da kewayon ma'aunin mai rikodin
  • Don Allah kar a yi tasiri da ƙarfi ga wannan rikodin
  • Sensors should be calibrated regularly to ensure their accuracy meets usage requirements
  • The measured values of the recorder may be affected by the following factors:

Kuskuren zafin jiki:
The stable time in the measurement environment is too short; Close to heat sources, cold sources, or directly exposed to sunlight.

Kuskuren danshi
The stable time in the measurement environment is too short; Long term exposure to steam, water mist, water curtains, or condensation environments.

gurbace
Kasancewa a cikin ƙura ko wani gurɓataccen muhalli

  • If the sensor is found to be blocked or contaminated, it should be wiped with a dust-free cloth dipped in clean water. It is strictly prohibited to use high molecular weight chemical solvents such as alcohol for wiping.
  • If scrapped, it must be strictly handled in accordance with the “Regulations on the Management of Recycling and Disposal of Waste Electrical and Electronic Products”.

FAQs

What should I do if the battery level is less than 20%?

To ensure data reliability, do not enable recording when the battery level is less than or equal to 20%.

How do I know if the device is activated?

Clicking on the activation button and seeing the screen display normally indicates that the device has been activated.

How can I export data from the device?

Connect the device to the computer via USB to generate PDF+CSV format data reports automatically.

Takardu / Albarkatu

Elitech Glog 5 Real Time Single Use IoT Data Logger [pdf] Manual mai amfani
Glog 5 T, Glog 5 TH, Glog 5 TE, Glog 5 THE, Glog 5 TLE, Glog 5 CO, Glog 5 Real Time Single Use IoT Data Logger, Glog 5, Real Time Single Use IoT Data Logger, Single Use IoT Data Logger, Data Logger, Logger

Magana

Bar sharhi

Ba za a buga adireshin imel ɗin ku ba. Ana yiwa filayen da ake buƙata alama *